Minimal detectable change of the disc‐fovea angle for ocular torsion assessment

Author(s):  
Elena Piedrahita‐Alonso ◽  
Alicia Valverde‐Megias ◽  
Beatriz Martin‐Garcia ◽  
Elena Hernandez‐Garcia ◽  
Rosario Gomez‐de‐Liano
2021 ◽  
pp. 026921552110251
Author(s):  
Marla K Beauchamp ◽  
Rudy Niebuhr ◽  
Patricia Roche ◽  
Renata Kirkwood ◽  
Kathryn M Sibley

Objective: To determine the minimal clinically important difference of the Mini-BESTest in individuals’ post-stroke. Design: Prospective cohort study. Setting: Outpatient stroke rehabilitation. Subjects: Fifty outpatients with stroke with a mean (SD) age of 60.8 (9.4). Intervention: Outpatients with stroke were assessed with the Mini-BESTest before and after a course of conventional rehabilitation. Rehabilitation sessions occurred one to two times/week for one hour and treatment duration was 1.3–42 weeks (mean (SD) = 17.4(10.6)). Main measures: We used a combination of anchor- and distribution-based approaches including a global rating of change in balance scale completed by physiotherapists and patients, the minimal detectable change with 95% confidence, and the optimal cut-point from receiver operating characteristic curves. Results: The average (SD) Mini-BESTest score at admission was 18.2 (6.5) and 22.4 (5.2) at discharge (effect size: 0.7) ( P = 0.001). Mean change scores on the Mini-BESTest for patient and physiotherapist ratings of small change were 4.2 and 4.3 points, and 4.7 and 5.3 points for substantial change, respectively. The minimal detectable change with 95% confidence for the Mini-BESTest was 3.2 points. The minimally clinical importance difference was determined to be 4 points for detecting small changes and 5 points for detecting substantial changes. Conclusions: A change of 4–5 points on the Mini-BEST is required to be perceptible to clinicians and patients, and beyond measurement error. These values can be used to interpret changes in balance in stroke rehabilitation research and practice.


2020 ◽  
Vol 8 (12) ◽  
pp. 232596712096518
Author(s):  
Karen Brage ◽  
Birgit Juul-Kristensen ◽  
John Hjarbaek ◽  
Eleanor Boyle ◽  
Per Kjaer ◽  
...  

Background: Shoulder pain is common, with a lifetime prevalence of up to 67%. Evidence is conflicting in relation to imaging findings and pain in the shoulder. Sonoelastography can be used to estimate tissue stiffness and may be a clinically relevant technique for diagnosing and monitoring tendon healing. Purpose: To evaluate changes in supraspinatus tendon stiffness using strain elastography (SEL) and associations with changes in patient-reported outcomes, supraspinatus tendon thickness, and grade of tendinopathy after 12 weeks of unilateral shoulder exercises in patients with supraspinatus tendinopathy. Study Design: Controlled laboratory study. Methods: A total of 23 patients with unilateral clinical supraspinatus tendinopathy performed 12 weeks of “standard care” exercises. At baseline and follow-up, supraspinatus tendon stiffness was measured bilaterally using SEL and compared with tendinopathy grading on magnetic resonance imaging scans and tendon thickness measured using conventional ultrasound. Patient-reported outcome measures included physical function and symptoms from the Disabilities of the Arm, Shoulder and Hand questionnaire and pain rating (visual analog scale). Results: No significant changes in SEL within or between groups (asymptomatic vs symptomatic tendon) were seen. All patient-reported outcomes showed significant improvement from baseline to follow-up, but with no change in tendinopathy grading and tendon thickness. No significant differences in the proportion of patients changing above the minimal detectable change in SEL and PROM were seen, except for discomfort while sleeping. Conclusion: Despite no significant within-group or between-group changes in SEL, significant improvements were found in patient-reported outcomes. An acceptable agreement between patients changing above the minimal detectable change in SEL and patient-reported outcome measure was seen. Further studies should explore the use of SEL to detect changes after tendon repair and long-term training potentially in subgroups of different tendinopathy phases. Clinical Relevance: In the short term, structural changes in supraspinatus tendons could not be visualized using SEL, indicating that a longer time span should be expected in order to observe structural changes, which should be considered before return to sports. Subgrouping based on stage of tendinopathy may also be important in order to evaluate changes over time with SEL among patients with supraspinatus tendinopathy. Registration: NCT03425357 ( ClinicalTrials.gov identifier).


Author(s):  
Chinonso N. Igwesi-Chidobe ◽  
Isaac O. Sorinola ◽  
Emma L. Godfrey

BACKGROUND: Illness perceptions predict chronic low back pain (CLBP) disability. This study cross-culturally adapted and validated the Igbo Brief Illness Perceptions Questionnaire (Igbo-BIPQ) in people with CLBP in rural/urban Nigeria. METHODS: A cross-cultural adaptation and validation of the Igbo-BIPQ was undertaken. The BIPQ was forward/back-translated by clinical/non-clinical translators. An expert review committee appraised the translations. The questionnaire was pre-tested on twelve rural Nigerian dwellers with CLBP. Internal consistency using Cronbach’s alpha; test-retest reliability using intra-class correlation coefficient and Bland-Altman plot; and minimal detectable change were investigated amongst 50 people with CLBP in rural and urban Nigeria. Construct validity was determined by correlating the Igbo-BIPQ score with those of eleven-point box scale and Igbo Roland Morris Disability Questionnaire (Igbo-RMDQ) using Pearson’s correlation analyses in 200 adults with CLBP in rural Nigeria. Ceiling and floor effects were investigated in both samples. RESULTS: Good face/content validity, internal consistency (α= 0.76) and intraclass correlation coefficient (ICC = 0.78); standard error of measurement and minimal detectable change of 5.44 and 15.08 respectively; moderate correlations with pain intensity and self-reported disability (r⩾ 0.4); no ceiling/floor effects were observed for Igbo-BIPQ. CONCLUSION: This study provides evidence of some aspects of validity and reliability of the Igbo-BIPQ.


Author(s):  
María Carmen Sánchez-González ◽  
Raquel García-Oliver ◽  
José-María Sánchez-González ◽  
María-José Bautista-Llamas ◽  
José-Jesús Jiménez-Rejano ◽  
...  

In our work, we determined the value of visual acuity (VA) with ETDRS charts (Early Treatment Diabetic Retinopathy Study). The purpose of the study was to determine the measurement reliabilities, calculating the correlation coefficient interclass (ICC), the value of the error associated with the measure (SEM), and the minimal detectable change (MDC). Forty healthy subjects took part. The mean age was 23.5 ± 3.1 (19 to 26) years. Visual acuities were measured with ETDRS charts (96% ETDRS chart nº 2140) and (10% SLOAN Contrast Eye Test chart nº 2153). The measurements were made (at 4 m) under four conditions: Firstly, photopic conditions with high contrast (HC) and low contrast (LC) and after 15 min of visual rest, mesopic conditions with high and low contrast. Under photopic conditions and high contrast, the ICC = 0.866 and decreased to 0.580 when the luminosity and contrast decreased. The % MDC in the four conditions was always less than 10%. It was minor under photopic conditions and HC (5.83) and maximum in mesopic conditions and LC (9.70). Our results conclude a high reliability of the ETDRS test, which is higher in photopic and high contrast conditions and lower when the luminosity and contrast decreases.


2021 ◽  
Author(s):  
A Wallin ◽  
M Kierkegaard ◽  
E Franzén ◽  
S Johansson

Abstract Objective The mini-BESTest is a balance measure for assessment of the underlying physiological systems for balance control in adults. Evaluations of test–retest reliability of the mini-BESTest in larger samples of people with multiple sclerosis (MS) are lacking. The purpose of this study was to investigate test–retest reliability of the mini-BESTest total and section sum scores and individual items in people with mild to moderate overall MS disability. Methods This study used a test–retest design in a movement laboratory setting. Fifty-four people with mild to moderate overall MS disability according to the Expanded Disability Status scale (EDSS) were included, with 28 in the mild subgroup (EDSS 2.0–3.5) and 26 in the moderate subgroup (EDSS 4.0–5.5). Test–retest reliability of the mini-BESTest was evaluated by repeated measurements taken 1 week apart. Reliability and measurement error were analyzed. Results Test–retest reliability for the total scores were considered good to excellent, with intraclass correlation coefficients of .88 for the whole sample, .83 for the mild MS subgroup, and .80 for the moderate MS subgroup. Measurement errors were small, with standard error of measurement and minimal detectable change of 1.3 and 3.5, respectively, in mild MS, and 1.7 and 4.7, respectively, in moderate MS. The limits of agreement were − 3.4 and 4.6. Test–retest reliability for the section scores were fair to good or excellent; weighted kappa values ranged from .62 to .83. All items but 1 showed fair to good or excellent test–retest reliability, and percentage agreement ranged from 61% to 100%. Conclusions The mini-BESTest demonstrated good to excellent test–retest reliability and small measurement errors and is recommended for use in people with mild to moderate MS. Impact Knowledge of limits of agreement and minimal detectable change contribute to interpretability of the mini-BESTest total score. The findings of this study enhance the clinical usefulness of the test for evaluation of balance control and for designing individually customized balance training with high precision and accuracy in people with MS.


2012 ◽  
Vol 26 (5) ◽  
pp. 507-514 ◽  
Author(s):  
Shuya Chen ◽  
Steven L. Wolf ◽  
Qin Zhang ◽  
Paul A. Thompson ◽  
Carolee J. Winstein

2021 ◽  
Vol 7 ◽  
pp. 233372142110489
Author(s):  
Yui Takada ◽  
Shigeharu Tanaka

Evaluation of motor function, such as gait ability, can accurately predict the subsequent occurrence of disability in older adults. There are no reports of standard error of the mean (SEM) or minimal detectable change (MDC) with respect to gait in Japanese long-term care insurance-certified individuals. The purpose of this study was to investigate the values of preferred gait, fast gait, and the timed up and go (TUG) test. This study included 46 participants using the Japanese long-term care insurance system. (age 86.5 ± 6.6 years, 12 men, 34 women). The duration of three gait were measured twice using a stopwatch. The SEM was 0.07 for preferred gait, 0.09 for fast gait and 2.59 for TUG. The MDC was 0.19 for preferred gait, 0.26 for fast gait, and 7.17 for TUG. The SEM and MDC values of preferred gait, fast gait, and TUG in this study corroborated with those of previous studies, whereas others were different. Considering that gait speed differs with the country, it may be difficult to compare it among different population groups. We obtained the results of gait speed of Japanese long-term care insurance-certified individuals, which is a new finding


Sign in / Sign up

Export Citation Format

Share Document