Independent factors of low radiation dose during AF ablation with cryoballoon or radiofrequency: Results from the “Go for zero fluoroscopy” registry

Author(s):  
Matthieu Gras ◽  
Rodrigue Garcia ◽  
Victor Waldmann ◽  
Vincent Bergere ◽  
David Duncker ◽  
...  
2020 ◽  
Vol 215 (2) ◽  
pp. W30-W30
Author(s):  
Matthew F. Covington ◽  
Matthew Brown

Circulation ◽  
2014 ◽  
Vol 130 (suppl_2) ◽  
Author(s):  
Luigi Di Biase ◽  
Rodney Horton ◽  
Chintan Trivedi ◽  
Prasant Mohanty ◽  
Sanghamitra Mohanty ◽  
...  

Introduction: Radiofrequency catheter ablation of atrial fibrillation is performed under fluoroscopic guidance and therefore carries radiation risk exposure for the both the patient and the operator. Three-dimensional mapping systems and newer technologies to allow non-fluoroscopic catheter visualization together with intracardiac echo have reduced but not abolished the fluoroscopy exposure. We aim to demonstrate the feasibility, the safety and the efficacy of catheter ablation for atrial fibrillation without the use of fluoroscopy. Methods: A totally fluoro-less approach was developed for AF ablation at our Institution. 94 consecutive AF patients underwent zero fluoroscopy catheter ablation for atrial fibrillation. In the zero fluoroscopy cases, the fluoroscopy arm was kept far away from the patient table. Access including double trans-septal, mapping with the Carto 3 system and ablation were all performed without fluoroscopy with the use of ICE and the Carto 3 system. These 94 patients were compared with 94 control patients matched for age, sex and type of AF who underwent AF ablation by the same operator with the use of fluoroscopy. Results: Baseline characteristics were similar between fluoroless (N=94, Age=64.5 ± 10.1, 75.5% male, 48% paroxysmal) and control (N=94, Age=65.1 ± 9.9, 72.3% male, 50% paroxysmal) group. Non-PV triggers were detected and ablated in 51 (54.3%) and 56 (59.6%) patients in fluoroless and control group respectively (p=0.5). Average fluoro time in control group was 10.1 ± 4.7 minutes. Procedure duration was comparable (120.4 ± 25.8 vs. 122.2 ± 28.7, p =0.6). After the short term median follow-up of 4.5 (4 – 6.5) months, 10 (10.6 %) patients in flourless and 9 (9.6%) patients in control group experienced recurrences (p=0.8).One pericardial effusion requiring pericardiocenteis occurred in the fluoroless group. Conclusions: Our series show that zero fluoroscopy ablation of atrial fibrillation with the use of newer technologies is feasible, safe and efficacious at the short term follow up. Importantly in our series the double transeptal was performed without fluoroscopy and the ablation was not limited to the pulmonary veins only but included ablation of the posterior wall, the coronary sinus and the left atrial appendage.


Author(s):  
Kayvan Nateghifard ◽  
David Low ◽  
Lola Awofala ◽  
Dilakshan Srikanthan ◽  
Jafri Kuthubutheen ◽  
...  

Abstract Background Knowledge of the cochlear implant array’s precise position is important because of the correlation between electrode position and speech understanding. Several groups have provided recent image processing evidence to determine scalar translocation, angular insertion depth, and cochlear duct length (CDL); all of which are being used for patient-specific programming. Cone beam computed tomography (CBCT) is increasingly used in otology due to its superior resolution and low radiation dose. Our objectives are as followed: Validate CBCT by measuring cochlear metrics, including basal turn diameter (A-value) and lateral wall cochlear duct length at different angular intervals and comparing it against microcomputed CT (uCT).Explore the relationship between measured lateral wall cochlear duct length at different angular intervals and insertion depth among 3 different length electrodes using CBCT. Methods The study was performed using fixed human cadaveric temporal bones in a tertiary academic centre. Ten temporal bones were subjected to the standard facial recess approach for cochlear implantation and imaged by CBCT followed by uCT. Measurements were performed on a three-dimensional reconstructed model of the cochlea. Sequential insertion of 3 electrodes (Med-El Flex24, 28 and Soft) was then performed in 5 bones and reimaged by CBCT. Statistical analysis was performed using Pearson’s correlation. Results There was good agreement between CBCT and uCT for cochlear metrics, validating the precision of CBCT against the current gold standard uCT in imaging. The A-value recorded by both modalities showed a high degree of linear correlation and did not differ by more than 0.23 mm in absolute values. For the measurement of lateral wall CDL at various points along the cochlea, there was a good correlation between both modalities at 360 deg and 720 deg (r = 0.85, p < 0.01 and r = 0.79, p < 0.01). The Flex24 electrode displayed consistent insertion depth across different bones. Conclusions CBCT reliably performs cochlear metrics and measures electrode insertion depth. The low radiation dose, fast acquisition time, diminished metallic artifacts and portability of CBCT make it a valid option for imaging in cochlear implant surgery.