Overall Efficiency of a Radial Fin Assembly Under Dehumidifying Conditions

1998 ◽  
Vol 120 (4) ◽  
pp. 299-304 ◽  
Author(s):  
L. Rosario ◽  
M. M. Rahman

The aim of this paper is the analysis of heat transfer in a radial fin assembly during the process of dehumidification. An individual finned tube geometry is a reasonable representation of heat exchangers used in air conditioning. The condensation process involves both heat and mass transfer and the cooling takes place by the removal of sensible as well as latent heat. The ratio of sensible to total heat is an important quantity that defines the heat transfer process during a dehumidifier operation. A one-dimensional model for heat transfer in the fin and the heat exchanger block is developed to study the effects of condensation on the fin surface. The combined heat and mass transfer process is modeled by incorporating the ratio of sensible to total heat in the formulation. The augmentation of heat transfer due to fin was established by comparing the heat transfer rate with and without fins under the same operating conditions. Calculations were carried out to study the effects of relative humidity and dry bulb temperature of the incoming air, and cold fluid temperature inside the coil on the performance of the heat exchanger. An analysis of the overall efficiency for the assembly was also done. Results were compared to those under dry conditions, wherever appropriate. Comparison between present results and those published for rectangular as well as radial fins under fully wet conditions were made. These comparisons established the validity of the present model. It was found that the heat transfer rate increased with increment in both dry bulb temperature and relative humidity of the air. The augmentation factor, however, decreased with increment in relative humidity and the dry bulb temperature. The fin efficiency decreased with relative humidity.

2015 ◽  
Vol 32 (8) ◽  
pp. 2419-2442 ◽  
Author(s):  
S. A. Moshizi

Purpose – The purpose of this paper is to focus on convective heat and mass transfer characteristics of Cu-water nanofluid inside a porous microchannel in the presence of a uniform magnetic field. The walls of the microchannel are subjected to constant asymmetric heat fluxes and also the first order catalytic reaction. To represent the non-equilibrium region near the surfaces, the Navier’s slip condition is considered at the surfaces because of the non-adherence of the fluid-solid interface and the microscopic roughness in microchannels. Design/methodology/approach – Employing the Brinkman model for the flow in the porous medium and the “clear fluid compatible” model as a viscous dissipation model, the conservative partial differential equations have been transformed into a system of ordinary ones via the similarity variables. Closed form exact solutions are obtained analytically based on dimensionless parameters of velocity, temperature and species concentration. Findings – Results show that the addition of Cu-nanoparticles to the fluid has a significant influence on decreasing concentration, temperature distribution at the both walls and velocity profile along the microchannel. In addition, total heat transfer in microchannel increases as nanoparticles add to the fluid. Slip parameter and Hartmann number have the decreasing effects on concentration and temperature distributions. Slip parameter leads to increase velocity profiles, while Hartmann number has an opposite trend in velocity profiles. These two parameters increase the total heat transfer rate significantly. Originality/value – In the present study, a comprehensive analytical solution has been obtained for convective heat and mass transfer characteristics of Cu-water nanofluid inside a porous microchannel in the presence of a uniform magnetic field. Finally, the effects of several parameters such as Darcy number, nanoparticle volume fraction, slip parameter, Hartmann number, Brinkman number, asymmetric heat flux parameter, Soret and Damkohler numbers on total heat transfer rate and fluid flow profiles are studied in more detail. To the best of author’s knowledge, no study has been conducted to this subject and the results are original.


2019 ◽  
Vol 2019 ◽  
pp. 1-12 ◽  
Author(s):  
Wen Fu ◽  
Li Zhang ◽  
Xiaowei Li ◽  
Xinxin Wu

The heat and mass transfer processes of natural convective condensation with noncondensable gases are very important for the passive containment cooling system of water cooled reactors. Numerical simulation of natural convective condensation with noncondensable gases was realized in the Fluent software by adding condensation models. The scaled AP600 containment condensation experiment was simulated to verify the numerical method. It was shown that the developed method can predict natural convective condensation with noncondensable gases well. The velocity, species, and density fields in the scaled AP600 containment were presented. The heat transfer rate distribution and the influences of the mass fraction of air on heat transfer rate were also analyzed. It is found that the driving force of natural convective condensation with noncondensable gases is mainly caused by the mass fraction difference but not temperature difference. The natural convective condensation with noncondensable gases in AP1000 containment was then simulated. The temperature, species, velocity, and heat flux distributions were obtained and analyzed. The upper head of the containment contributes to 35.1% of the total heat transfer rate, while its area only takes 25.4% of the total condensation area of the containment. The influences of the mass fraction of low molecular weight noncondensable gas (hydrogen) on the natural convective condensation were also discussed based on the detailed species, density, and velocity fields. The results show that addition of hydrogen (production of zirconium-water reaction after severe accident) will weaken the intensity of natural convection and the heat and mass transfer processes significantly. When hydrogen contributes to 50% mole fraction of the noncondensable gases, the heat transfer coefficient will be reduced to 45%.


2016 ◽  
Vol 78 (5-5) ◽  
Author(s):  
Dewanto Harjunowibowo ◽  
Dina Nur Adilah ◽  
Dwi Teguh Rahardjo ◽  
Danar S. Wijayanto ◽  
Fredy Surahmanto ◽  
...  

The density of adsorbent bed significantly contributed to solar cooling performance (COP). The density determines how well the heat and mass transfer are. Besides that, the COP is also determined by ambient temperature. This research aims to investigate the affect of temperature of a connecting pipe, as a representative of different ambient temperature against a solar cooling machine performance. The experiment will show in what condition a solar cooling is going to have a better cooling result. The data used in this case was taken experimentally and conducted using a solar cooling machine equipped with temperature measurement units such as thermocouple logger. For cold ambient temperature, in adsorption process, refrigerant vapour flows to the generator through the connecting pipe cooled by water and kept steady. The results show that the COP, heat and mass transfer of adsorbent bed of the system in the adsorption process on a warm condition are better than in a cold environment. In the warm condition the COP system is 0.24, the heat transfer rate is 0.06 °C/minute, and the mass transfer rate is 1.09 ml/minute. Whereas, in the cold condition the COP system is 0.23, the heat transfer rate is 0.05 °C/minute, and the mass transfer rate is 1.04 ml/minute. 


2013 ◽  
Vol 284-287 ◽  
pp. 908-914
Author(s):  
King Leung Wong ◽  
Wen Lih Chen ◽  
Li Wen Po

Log mean temperature difference (LMTD) method neglecting the influence of heat radiation is conventionally used to calculate the total heat transfer rate of heat exchangers. From recent investigation of a single-pipe heat exchanger in some practical situations, it is found that the total heat transfer rate error of single-pipe heat exchanger obtained by LMTD method is up to 40% in the situation of oxidized metal heat exchanger with higher surface emissivity located in ambient air with low heat convection coefficient. A log mean heat transfer rate (LMHTR) method considering heat radiation has been developed to calculate the total heat transfer rate of a single-pipe heat exchanger and more accurate results can be achieved. It is also found in the present investigation that LMTD method is also not suitable to apply to non-insulated double-pipe heat exchangers and a more accurate LMHTR method considering heat radiation is developed to obtain the more reasonable results.


Author(s):  
Prabhugouda Mallanagouda Patil ◽  
Shashikant A. ◽  
Ebrahim Momoniat

Purpose This study aims to investigate the unsteady magnetohydrodynamic mixed convective nanofluid flow by using Buongiorno two-phase model to achieve an appropriate mechanism to improve the efficiency of solar energy systems by mitigating the energy losses. Design/methodology/approach The transport phenomena occurring in this physical problem are modelled using nonlinear partial differential equations and are non-dimensionalised by using non-similar transformations. The quasilinearisation technique is used to solve the resulting system with the help of a finite difference scheme. Findings The study reveals that the effect of the applied transverse magnetic parameter is to increase the temperature profile and to reduce the wall heat transfer rate. The Brownian diffusion and thermophoresis parameters that characterise the nanofluids contribute to the reduction in wall heat transfer rate. The presence of nanoparticles in the fluid gives rise to critical values for the thermophoresis parameter describing the behaviour of the wall heat and mass transfer rates. Wall heating and cooling are analysed by considering the percentage increase or percentage decrease in the heat and mass transfer rates in the presence of nanoparticles in the fluid. Research limitations/implications The investigation on wall cooling/heating leads to the analysis of control parameters applicable to the industrial design of thermal systems for energy storage, energy harvesting and cooling applications. Practical implications The analysis of the control parameters is of practical value to the solar industry. Social implications In countries, such as South Africa, daily power cuts are a reality. Any research into improving the quality of energy obtained from alternate sources is a national necessity. Originality/value From the literature survey in the present study, it is found that no similar work has been reported in the open literature that analyses the time-dependent mixed convection flow along the exponentially stretching surface in the presence of the effects of a magnetic field, nanoparticles and non-similar solutions.


Author(s):  
Yao Li ◽  
Haiqing Si ◽  
Jingxuan Qiu ◽  
Yingying Shen ◽  
Peihong Zhang ◽  
...  

Abstract The plate-fin heat exchanger has been widely applied in the field of air separation and aerospace due to its high specific surface area of heat transfer. However, the low heat transfer efficiency of its plate bundles has also attracted more attention. It is of great significance to optimize the structure of plate-fin heat exchanger to improve its heat transfer efficiency. The plate bundle was studied by combining numerical simulation with experiment. Firstly, according to the heat and mass transfer theory, the plate bundle calculation model of plate-fin heat exchanger was established, and the accuracy of the UDF (User-Defined Functions) for describing the mass and heat transfer was verified. Then, the influences of fin structure parameters on the heat and mass transfer characteristics of channel were discussed, including the height, spacing, thickness and length of fins. Finally the influence of various factors on the flow field performance under different flow states was integrated to complete the optimal design of the plate bundle.


2013 ◽  
Vol 448-453 ◽  
pp. 3259-3269
Author(s):  
Zhi Wei Li ◽  
Hong Zhou He ◽  
Huang Huang Zhuang

The characteristics of the external heat exchanger (EHE) for a 4 MWth circulation fluidized bed combustor were studied in the present paper. The length, width and height of EHE were 1.5 m, 0.8 m and 9 m, respectively. The circulating ash flow passing the heating surface bed could be controlled by adjusting the fluidizing air flow and the heating transferred from the circulating ash to the cooling water. The ash flow rate passing through the heat transfer bed was from 0.4 to 2.2 kg/s. The ash average temperature was from 500 to 750 °C. And the heat transfer rate between the ash and the cooling water was between 150 and 300 W/(m2·°C). The relationships among the circulating ash temperature, the heat transfer, heat transfer rate, the heat transfer coefficient and the circulating ash flow passing through the heating exchange cell were also presented and could be used for further commercial EHE design.


2020 ◽  
Vol 14 (1) ◽  
pp. 25
Author(s):  
Abdul Aziz Rohman Hakim ◽  
Engkos Achmad Kosasih

This paper discusses heat and mass transfer in cooling tower fill. In this research, dry bulb temperature at the bottom fill, ambient relative humidity, air stream velocity entering fill, dry bulb temperature leaving the fill, relative humidity of air leaving the fill, inlet and outlet water temperature of cooling tower were measured. Those data used in heat and mass transfer calculation in cooling tower fill. Then, do the heat and mass transfer calculation based on proposed approch. The results are compared with design data. The design and analogy method showed different  result. The parameter which influence the heat transfer at cooling tower are represented by coefficient of heat transfer hl and coefficient of mass transfer k­l. The differencies result between design and analogy method shows that there is important parameter which different. Deeply study needed for it.


2005 ◽  
Vol 127 (2) ◽  
pp. 179-188 ◽  
Author(s):  
Devashish Shrivastava ◽  
Benjamin McKay ◽  
Robert B. Roemer

Counter-current (vessel–vessel) heat transfer has been postulated as one of the most important heat transfer mechanisms in living systems. Surprisingly, however, the accurate quantification of the vessel–vessel, and vessel–tissue, heat transfer rates has never been performed in the most general and important case of a finite, unheated/heated tissue domain with noninsulated boundary conditions. To quantify these heat transfer rates, an exact analytical expression for the temperature field is derived by solving the 2-D Poisson equation with uniform Dirichlet boundary conditions. The new results obtained using this solution are as follows: first, the vessel–vessel heat transfer rate can be a large fraction of the total heat transfer rate of each vessel, thus quantitatively demonstrating the need to accurately model the vessel–vessel heat transfer for vessels imbedded in tissues. Second, the vessel–vessel heat transfer rate is shown to be independent of the source term; while the heat transfer rates from the vessels to the tissue show a significant dependence on the source term. Third, while many previous studies have assumed that (1) the total heat transfer rate from vessels to tissue is zero, and/or (2) the heat transfer rates from paired vessels (of different sizes and at different temperatures) to tissue are equal to each other the current analysis shows that neither of these conditions is met. The analytical solution approach used to solve this two vessels problem is general and can be extended for the case of “N” arbitrarily located vessels.


Sign in / Sign up

Export Citation Format

Share Document