Transit Time Correlation—A Survey on Its Applications to Measuring Transport Phenomena

1974 ◽  
Vol 96 (4) ◽  
pp. 414-420 ◽  
Author(s):  
F. Mesch ◽  
R. Fritsche ◽  
H. Kipphan

A survey is given on different types of correlation methods and their application to measuring velocity of moving surfaces, flow rates, and to ranging. The different methods are unified by regarding them as special cases of classical identification methods for dynamical systems. Special difficulties occurring in flow rate measurement are discussed in some detail, and some problems yet to be solved are indicated.

2021 ◽  
Vol 9 ◽  
Author(s):  
Srivats Sarathy ◽  
Marco A. Nino ◽  
Abduldattar H. Alsaedi ◽  
Srinivasan Rajagopal ◽  
Syed Mubeen ◽  
...  

In vivo measurement of the flow rate of physiological fluids such as the blood flow rate in the heart is vital in critically ill patients and for those undergoing surgical procedures. The reliability of these measurements is therefore quite crucial. However, current methods in practice for measuring flow rates of physiological fluids suffer from poor repeatability and reliability. Here, we assessed the feasibility of a flow rate measurement method that leverages time transient electrochemical behavior of a tracer that is injected directly into a medium (the electrochemical signal caused due to the tracer injectate will be diluted by the continued flow of the medium and the time response of the current—the electrodilution curve—will depend on the flow rate of the medium). In an experimental flow loop apparatus equipped with an electrochemical cell, we used the AC voltammetry technique and tested the feasibility of electrodilution-based measurement of the flow rate using two mediums—pure water and anticoagulated blood—with 0.9 wt% saline as the injectate. The electrodilution curve was quantified using three metrics—change in current amplitude, total time, and change in the total charge for a range of AC voltammetry settings (peak voltages and frequencies). All three metrics showed an inverse relationship with the flow rate of water and blood, with the strongest negative correlation obtained for change in current amplitude. The findings are a proof of concept for the electrodilution method of the flow rate measurement and offer the potential for physiological fluid flow rate measurement in vivo.


Author(s):  
Behrokh Abbasnejad ◽  
David McGloin ◽  
Lee Clemon

Abstract Direct low flow sensing is of interest to many applications in medical and biochemical industries. Low flow rate measurement is still challenging, and conventional flow sensors such as hot films, hot wires and Pitot probes are not capable of measuring very low flow rates accurately. In some applications that require flow measurement in a small diameter tubing (e.g. intravenous (IV) infusion), using such sensors also becomes mechanically impractical. Herein, a flexible laser-induced graphitic (LIG) piezoresistive flow sensor has been fabricated in a cost-effective single processing step. The capability of the LIG sensor in very low flow rate measurement has been investigated by embedding the sensor within an intravenous (IV) line. The embedded LIG hair-like sensor was tested at ambient temperature within the IV line at flow rates ranging from 0 m/s to 0.3 m/s (IV infusion free-flow rate). The LIG hair-like sensor presented in this study detects live flow rates of IV infusions with a threshold detection limit as low as 0.02 m/s. Moreover, the deformation of the LIG hair-like sensor that lead to resistance change in response to various flow rates is simulated using COMSOL Multiphysics.


2021 ◽  
pp. 13-19
Author(s):  
Zhanat А. Dayev ◽  
Gulzhan E. Shopanova ◽  
Bakytgul А. Toksanbaeva

The article deals with one of the important tasks of modern flow measurement, which is related to the measurement of the flow rate and the amount of wet gas. This task becomes especially important when it becomes necessary to obtain information about the separate amount of the dry part of the gas that is contained in the form of a mixture in the wet gas stream. The paper presents the principle of operation and structure of the invariant system for measuring the flow rate of wet gas, which is based on the combined use of differential pressure flowmeters and Coriolis flowmeters. The operation of the invariant wet gas flow rate measurement system is based on the simultaneous application of the multichannel principle and the partial flow measurement method. Coriolis flowmeters and the differential pressure flowmeter are used as the main elements of the system. The proposed measurement system does not offer applications for gases with abundant drip humidity. The article provides information about the test results of the proposed invariant system. The estimation of the metrological characteristics of the invariant system when measuring the flow rate of wet gas is given. The obtained test results of the invariant wet gas flow rate measurement system are relevant for natural gas production, transportation, and storage facilities.


Author(s):  
Mohd. Fua’ad Rahmat ◽  
Wee Lee Yaw

This paper discussed the electrostatic sensors that have been constructed for real–time mass flow rate measurement of particle conveying in a Pneumatic pipeline. Many industrial processes require continuous, smooth, and consistent delivery of solids materials with a high accuracy of controlled flow rate. This requirement can only be achieved by installing a proper measurement system. Electrostatic sensor offers the most inexpensive and simplest means of measuring solids flows in pipes. Key words: Electrostatic sensor, cross-correlation, peripheral velocity


Sign in / Sign up

Export Citation Format

Share Document