An In Vitro Study of Transendothelial Albumin Transport in a Steady State Pipe Flow at High Shear Rates

1976 ◽  
Vol 98 (3) ◽  
pp. 488-493 ◽  
Author(s):  
Thomas H. Reif ◽  
Robert M. Nerem ◽  
Francis A. Kulacki

The effect of high wall shear rates on the uptake of 131I-albumin by the arterial wall has been studied in vitro using common carotid arteries excised from anesthetized dogs and perfused with a steady state flow of homologous serum. Wall uptake was found to depend nearly linearly upon wall shear rate. The overall transport of 131I-albumin from the perfusing fluid to the vessel wall appears to be rate controlled by a shear dependent fluid-wall interface process. This study was carried out at high shear rates for flows which were transitional and turbulent. Because of the complexity of such flows, direct measurements of pressure drop were used to determine the shear rate at the vessel wall. Simultaneous pressure drop and flow measurements allowed the determination of the friction factor as a function of Reynolds number; results obtained at the higher Reynolds numbers correspond to those for a rigid pipe with a relative roughness of 0.05.

2011 ◽  
Vol 106 (12) ◽  
pp. 1062-1068 ◽  
Author(s):  
Naoki Tsuji ◽  
Yuko Honda ◽  
Chikako Kamisato ◽  
Yoshiyuki Morishima ◽  
Toshiro Shibano ◽  
...  

SummaryEdoxaban is an oral, direct factor Xa (FXa) inhibitor under late-phase clinical development. This study compared the antithrombotic efficacy of edoxaban with that of an indirect FXa inhibitor, fondaparinux, in in vivo venous and arterial thrombosis models and in ex vivo perfusion chamber thrombosis model under low and high shear rates in rats. Venous and arterial thrombi were induced by platinum wire insertion into the inferior vena cava and by application of FeCl3 to the carotid artery, respectively. The perfusion chamber thrombus was formed by blood perfusion into a collagen-coated capillary at 150 s-1 (low shear rate) and 1,600 s-1 (high shear rate). Effective doses of edoxaban that reduced thrombus formation by 50% (ED50) in venous and arterial thrombosis models were 0.076 and 0.093 mg/kg/h, respectively. In contrast, ED50 of fondaparinux in the arterial thrombosis model (>10 mg/kg/h) was markedly higher compared to ED50 in the venous thrombosis model (0.021 mg/kg/h). In the perfusion chamber thrombosis model, the ratio of ED50 under high shear rate (1.13 mg/kg/h) to that under low shear rate (0.63 mg/kg/h) for edoxaban was 1.9, whereas that for fondaparinux was more than 66. While the efficacy of fondaparinux markedly decreased in arterial thrombosis and in a high-shear state, edoxaban exerted consistent antithrombotic effects regardless of flow conditions. These results suggest that shear rate is a key factor in different antithrombotic effects between edoxaban and fondaparinux.


Blood ◽  
1987 ◽  
Vol 70 (4) ◽  
pp. 1214-1217
Author(s):  
E Fressinaud ◽  
D Baruch ◽  
C Rothschild ◽  
HR Baumgartner ◽  
D Meyer

Although it is well established that plasma von Willebrand Factor (vWF) is essential to platelet adhesion to subendothelium at high shear rates, the role of platelet vWF is less clear. We studied the respective role of both plasma and platelet vWF in mediating platelet adhesion to fibrillar collagen in a parallel-plate perfusion chamber. Reconstituted blood containing RBCs, various mixtures of labeled washed platelets and plasma from controls or five patients with severe von Willebrand disease (vWD), was perfused through the chamber for five minutes at a shear rate of 1,600 s-1. Platelet-collagen interactions were estimated by counting the radioactivity in deposited platelets and by quantitative morphometry. When the perfusate consisted of normal platelets suspended in normal plasma, platelet deposition on the collagen was 24.7 +/- 3.6 X 10(6)/cm2 (mean +/- SEM, n = 6). Significantly less deposition (16 +/- 2.3) was observed when vWD platelets were substituted for normal platelets. In mixtures containing vWD plasma, significantly greater deposition (9 +/- 2.2) was obtained with normal than with vWD platelets (1 +/- 0.4) demonstrating a role for platelet vWF in mediating the deposition of platelets on collagen. Morphometric analysis confirmed these data. Our findings indicate that platelet, as well as plasma, vWF mediates platelet-collagen interactions at a high shear rate.


1992 ◽  
Vol 289 ◽  
Author(s):  
John R. Melrose

AbstractAn overview is given of theories of aggregates under flow. These generally assume some sort of structural breakdown as the shear rate is increased. Models vary with both the rigidity of the bonding and the level of treatment of hydrodynamics. Results are presented for simulations of a Rouse model of non-rigid, (i.e. central force) weakly bonded aggregates. In large scale simulations different structures are observed at low and high shear rates. The change from one structure to another is associated with a change in the rate of shear thinning. The model captures low shear rate features of real systems absent in previous models: this feature is ascribed to agglomerate deformations. Quantitatively, the model is two orders of magnitude out from experiment but some scaling is possible.


Blood ◽  
1985 ◽  
Vol 65 (1) ◽  
pp. 85-90 ◽  
Author(s):  
HV Stel ◽  
KS Sakariassen ◽  
PG de Groot ◽  
JA van Mourik ◽  
JJ Sixma

Abstract A monoclonal antibody directed against the von Willebrand factor moiety (vWF) of factor VIII-von Willebrand factor (FVIII-vWF), which blocks ristocetin-induced platelet aggregation as well as the binding of FVIII- vWF to platelets in the presence of ristocetin, inhibited platelet adherence to human artery subendothelium when present in normal flowing blood. This monoclonal antibody, CLB-RAg 35, inhibited platelet adherence as a function of the shear rate. At wall shear rates below 500 s-1, platelet adherence was not affected, but at higher shear rates platelet adherence was gradually inhibited, reaching an average of 11% of the normal value at 2,500 s-1. Indirect immunofluorescence established the reactivity of CLB-RAg 35 with vWF present in artery subendothelium. Pretreatment of normal vessel walls with this antibody inhibited adherence of platelets in blood from a patient with severe homozygous von Willebrand's disease and in blood from normal individuals. The inhibition was shear-rate dependent and significant at high shear rates (2,500 s-1). By adding increasing amounts of purified FVIII-vWF to normal blood, the inhibition was gradually overcome. These data indicate that vWF present in the vessel wall contributes appreciably to platelet adherence. At high wall shear rates, platelet adherence is mediated virtually completely by both plasma FVIII-vWF and vWF in the vessel wall. At low wall shear rates (below 500 s-1), platelet adherence occurs independent of FVIII-vWF in plasma and vWF in the vessel wall.


2004 ◽  
Vol 70 (12) ◽  
pp. 7426-7435 ◽  
Author(s):  
Alexander H. Rickard ◽  
Andrew J. McBain ◽  
Amy T. Stead ◽  
Peter Gilbert

ABSTRACT The development of freshwater multispecies biofilms at solid-liquid interfaces occurs both in quiescent waters and under conditions of high shear rates. However, the influence of hydrodynamic shear rates on bacterial biofilm diversity is poorly understood. We hypothesized that different shear rates would significantly influence biofilm diversity and alter the relative proportions of coaggregating and autoaggregating community isolates. In order to study this hypothesis, freshwater biofilms were developed at five shear rates (<0.1 to 305 S−1) in a rotating concentric cylinder reactor fed with untreated potable water. Eubacterial diversity was assessed by denaturing gradient gel electrophoresis (DGGE) and culturing on R2A agar. Fifty morphologically distinct biofilm strains and 16 planktonic strains were isolated by culturing and identified by partial 16S rRNA gene sequencing, and their relatedness was determined by the construction of a neighbor-joining phylogenetic tree. Phylogenetic and DGGE analyses showed an inverse relationship between shear rate and bacterial diversity. An in vitro aggregation assay was used to assess the relative proportions of coaggregating and autoaggregating species from each biofilm. The highest proportion of autoaggregating bacteria was present at high shear rates (198 to 305 S−1). The intermediate shear rate (122 S−1) selected for the highest proportion of coaggregating bacteria (47%, or 17 of a possible 36 coaggregation interactions). Under static conditions (<0.1 S−1), 41 (33%) of a possible 125 coaggregation interactions were positive. Few coaggregation (3.3%) or autoaggregation (25%) interactions occurred between the 16 planktonic strains. In conclusion, these data show that shear rates affect biofilm diversity as well as the relative proportions of aggregating bacteria.


Blood ◽  
1985 ◽  
Vol 65 (1) ◽  
pp. 85-90 ◽  
Author(s):  
HV Stel ◽  
KS Sakariassen ◽  
PG de Groot ◽  
JA van Mourik ◽  
JJ Sixma

A monoclonal antibody directed against the von Willebrand factor moiety (vWF) of factor VIII-von Willebrand factor (FVIII-vWF), which blocks ristocetin-induced platelet aggregation as well as the binding of FVIII- vWF to platelets in the presence of ristocetin, inhibited platelet adherence to human artery subendothelium when present in normal flowing blood. This monoclonal antibody, CLB-RAg 35, inhibited platelet adherence as a function of the shear rate. At wall shear rates below 500 s-1, platelet adherence was not affected, but at higher shear rates platelet adherence was gradually inhibited, reaching an average of 11% of the normal value at 2,500 s-1. Indirect immunofluorescence established the reactivity of CLB-RAg 35 with vWF present in artery subendothelium. Pretreatment of normal vessel walls with this antibody inhibited adherence of platelets in blood from a patient with severe homozygous von Willebrand's disease and in blood from normal individuals. The inhibition was shear-rate dependent and significant at high shear rates (2,500 s-1). By adding increasing amounts of purified FVIII-vWF to normal blood, the inhibition was gradually overcome. These data indicate that vWF present in the vessel wall contributes appreciably to platelet adherence. At high wall shear rates, platelet adherence is mediated virtually completely by both plasma FVIII-vWF and vWF in the vessel wall. At low wall shear rates (below 500 s-1), platelet adherence occurs independent of FVIII-vWF in plasma and vWF in the vessel wall.


2002 ◽  
Vol 25 (4) ◽  
pp. 306-312 ◽  
Author(s):  
S. Klaus ◽  
S. Körfer ◽  
K. Mottaghy ◽  
H. Reul ◽  
B. Glasmacher

Devices for modern heart support are minimized to reduce priming blood volume and contact area with foreign surfaces. Their flow fields are partly governed by very high velocity gradients. In order to investigate blood damage, porcine and human blood was passed through a narrow Couette type shear gap applying defined high shear rates within the typical range for devices such as blood pumps or artificial heart valves (γ = 1800/s to 110,000/s for 400 ms). Traumatization profiles of both blood species were recorded in terms of hemolysis and platelet count. Sublethal damage in terms of platelet (PF4) and complement activation (C5a) was additionally measured for human blood. Results for porcine and human blood were very similar. Hemolysis was not started until critical shear rates of about 80,000/s. Impact on platelets was severe with drops in cell count of up to 65% (at γ = 55,000/s to 110,000/s) likely to set stronger limits to the design layout of devices than hemolysis. Concentrations of PF4 and C5a clearly increased with shear rate exhibiting stronger gradients where hemolysis started. Due to the similar results of porcine and human blood for hemolysis and platelet drop, porcine blood seems to be suitable for device testing. Selection of blood species would thus depend on handling, availability and analysis demands.


2021 ◽  
Author(s):  
Patrick Wilms ◽  
Jörg Hinrichs ◽  
Reinhard Kohlus

AbstractModelling the macroscopic rheology of non-Brownian suspensions is complicated by the non-linear behaviour that originates from the interaction between solid particles and the liquid phase. In this contribution, a model is presented that describes suspension rheology as a function of solid volume fraction and shear rate dependency of both the liquid phase, as well as the suspension as a whole. It is experimentally validated using rotational rheometry ($$\varphi$$ φ ≤ 0.40) and capillary rheometry (0.55 ≤ $$\varphi$$ φ  ≤ 0.60) at shear rates > 50 s−1. A modified Krieger-Dougherty relation was used to describe the influence of solid volume fraction on the consistency coefficient, $$K$$ K , and was fitted to suspensions with a shear thinning liquid phase, i.e. having a flow index, $$n$$ n , of 0.50. With the calculated fit parameters, it was possible to predict the consistency coefficients of suspensions with a large variation in the shear rate dependency of the liquid phase ($$n$$ n = 0.20–1.00). With increasing solid volume fraction, the flow indices of the suspensions were found to decrease for Newtonian and mildly shear thinning liquid phases ($$n$$ n ≥0.50), whereas they were found to increase for strongly shear thinning liquid phases ($$n$$ n ≤0.27). It is hypothesized that this is related to interparticle friction and the relative contribution of friction forces to the viscosity of the suspension. The proposed model is a step towards the prediction of the flow curves of concentrated suspensions with non-Newtonian liquid phases at high shear rates.


1968 ◽  
Vol 90 (3) ◽  
pp. 561-569 ◽  
Author(s):  
L. H. Bernd

Based on an examination of the characteristics of shear viscosity versus shear rate, it was postulated that high tensile and compressive stresses might exist in certain liquids at very high shear rates. If obtainable, these stresses could be important as load-bearing mechanisms in high-speed machine elements, and as a sealing mechanism in radial face seals. Such stresses should be evident in a polymer fortified oil, or in a liquid comprised of molecules possessing an appreciable length to width ratio. Therefore, a jet reaction viscometer reaching 107 sec−1 shear rate was developed to explore this possibility. Tests with polyisobutylene dissolved in a kerosene showed that elastic stresses were dominant with respect to viscous stresses at high shear rates. Tensile stresses up to more thn 1000 psi were obtained. However, the life of the polyisobutylene molecule was short. Hence it is concluded that normal stresses of appreciable magnitude can exist in high-speed machine elements under favorable conditions to affect their operation.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Britt J. M. van Rooij ◽  
Gábor Závodszky ◽  
Alfons G. Hoekstra ◽  
David N. Ku

Abstract Occlusive thrombi formed under high flow shear rates develop very rapidly in arteries and may lead to myocardial infarction or stroke. Rapid platelet accumulation (RPA) and occlusion of platelet-rich thrombi and clot shrinkage have been studied after flow arrest. However, the influence of margination and shear rate on occlusive clot formation is not fully understood yet. In this study, the influence of flow on the growth and shrinkage of a clot is investigated. Whole blood (WB) and platelet-rich plasma (PRP) were perfused at high shear rates (> 3,000 s−1) through two microfluidic systems with a stenotic section under constant pressure. The stenotic section of the two devices are different in stenotic length (1,000 vs 150 μm) and contraction angle of the stenosis (15° vs 80°). In all experiments, the flow chamber occluded in the stenotic section. Besides a significantly increased lag time and decreased RPA rate for PRP compared to WB (p < 0.01), the device with a shorter stenotic section and steeper contraction angle showed a shear-dependent occlusion and lag time for both PRP and WB. This shear-dependent behavior of the platelet aggregate formation might be caused by the stenotic geometry.


Sign in / Sign up

Export Citation Format

Share Document