Enhanced Flow Boiling Over Open Microchannels With Uniform and Tapered Gap Manifolds

2013 ◽  
Vol 135 (6) ◽  
Author(s):  
Satish G. Kandlikar ◽  
Theodore Widger ◽  
Ankit Kalani ◽  
Valentina Mejia

Flow boiling in microchannels has been extensively studied in the past decade. Instabilities, low critical heat flux (CHF) values, and low heat transfer coefficients have been identified as the major shortcomings preventing its implementation in practical high heat flux removal systems. A novel open microchannel design with uniform and tapered manifolds (OMM) is presented to provide stable and highly enhanced heat transfer performance. The effects of the gap height and flow rate on the heat transfer performance have been experimentally studied with water. The critical heat fluxes (CHFs) and heat transfer coefficients obtained with the OMM are significantly higher than the values reported by previous researchers for flow boiling with water in microchannels. A record heat flux of 506 W/cm2 with a wall superheat of 26.2 °C was obtained for a gap size of 0.127 mm. The CHF was not reached due to heater power limitation in the current design. A maximum effective heat transfer coefficient of 290,000 W/m2 °C was obtained at an intermediate heat flux of 319 W/cm2 with a gap of 0.254 mm at 225 mL/min. The flow boiling heat transfer was found to be insensitive to flow rates between 40–333 mL/min and gap sizes between 0.127–1.016 mm, indicating the dominance of nucleate boiling. The OMM geometry is promising to provide exceptional performance that is particularly attractive in meeting the challenges of high heat flux removal in electronics cooling applications.

Energies ◽  
2020 ◽  
Vol 13 (11) ◽  
pp. 2970
Author(s):  
Donghui Zhang ◽  
Haiyang Xu ◽  
Yi Chen ◽  
Leiqing Wang ◽  
Jian Qu ◽  
...  

Flow boiling in microporous layers has attracted a great deal of attention in the enhanced heat transfer field due to its high heat dissipation potential. In this study, flow boiling experiments were performed on both porous microchannels and a copper-based microchannel, using water as the coolant. As the heat flux was less than 80 W/cm2, the porous microchannels presented significantly higher boiling heat transfer coefficients than the copper-based microchannel. This was closely associated with the promotion of the nucleation site density of the porous coating. With the further increase in heat flux, the heat transfer coefficients of the porous microchannels were close to those of the copper-based sample. The boiling process in the porous microchannel was found to be dominated by the nucleate boiling mechanism from low to moderate heat flux (<80 W/cm2).This switched to the convection boiling mode at high heat flux. The porous samples were able to mitigate flow instability greatly. A visual observation revealed that porous microchannels could suppress the flow fluctuation due to the establishment of a stable nucleate boiling process. Porous microchannels showed no advantage over the copper-based sample in the critical heat flux. The optimal thickness-to-particle-size ratio (δ/d) for the porous microchannel was confirmed to be between 2–5. In this range, the maximum enhanced effect on boiling heat transfer could be achieved.


2021 ◽  
Author(s):  
Ji Hwan Lim ◽  
Minkyu Park

Abstract The onset of nucleate boiling (ONB) is the point at which the heat transfer mechanism in fluids changes and is one of the thermo-hydraulic factors that must be considered when establishing a cooling system operation strategy. Because the high heat flux of several MW/m2, which is loaded within a tokamak, is applied under a one-side heating condition, it is necessary to determine a correlative relation that can predict ONB under special heating conditions. In this study, the ONB of a one-side-heated screw tube was experimentally analyzed via a subcooled flow boiling experiment. The helical nut structure of the screw tube flow path wall allows for improved heat transfer performance relative to smooth tubes, providing a screw tube with a 53.98% higher ONB than a smooth tube. The effects of the system parameters on the ONB heat flux were analyzed based on the changes in the heat transfer mechanism, with the results indicating that the flow rate and degree of subcooling are proportional to the ONB heat flux because increasing these factors improves the forced convection heat transfer and increases the condensation rate, respectively. However, it was observed that the liquid surface tension and latent heat decrease as the pressure increases, leading to a decrease in the ONB heat flux. An evaluation of the predictive performance of existing ONB correlations revealed that most have high error rates because they were developed based on ONB experiments on micro-channels or smooth tubes and not under one-side high heat load conditions. To address this, we used dimensional analysis based on Python code to develop new ONB correlations that reflect the influence of system parameters.


Author(s):  
Hailei Wang ◽  
Richard Peterson

Flow boiling and heat transfer enhancement in four parallel microchannels using a dielectric working fluid, HFE 7000, was investigated. Each channel was 1000 μm wide and 510 μm high. A unique channel surface enhancement technique via diffusion bonding a layer of conductive fine wire mesh onto the heating wall was developed. According to the obtained flow boiling curves for both the bare and mesh channels, the amount of wall superheat was significantly reduced for the mesh channel at all stream-wise locations. This indicated that the nucleate boiling in the mesh channel was enhanced due to the increase of nucleation sites the mesh introduced. Both the nucleate boiling dominated and convective evaporation dominated regimes were identified. In addition, the overall trend for the flow boiling heat transfer coefficient, with respect to vapor quality, was increasing until the vapor quality reached approximately 0.4. The critical heat flux (CHF) for the mesh channel was also significantly higher than that of the bare channel in the low vapor quality region. Due to the fact of how the mesh was incorporated into the channels, no pressure drop penalty was identified for the mesh channels. Potential applications for this kind of mesh channel include high heat-flux electronic cooling systems and various energy conversion systems.


2013 ◽  
Vol 589-590 ◽  
pp. 559-564
Author(s):  
Xi Bing Li ◽  
Yun Shi Ma ◽  
Xun Wang ◽  
Ming Li

As a highly efficient heat transfer component, a micro heat pipe (MHP) has been widely applied to the situations with high heat flux concentration. However, a MHPs heat transfer performance is affected by many factors, among which, working fluid inventory has great influence on the security, reliability and frost resistance of its heat transfer performance. In order to determine the appropriate working fluid inventory for grooved MHPs, this paper first analyzed the working principle, major heat transfer limits and heat flux distribution law of grooved MHPs in electronic chips with high heat flux concentration, then established a mathematic model for the working fluid inventory in grooved MHPs. Finally, with distilled water being the working fluid, a series of experimental investigations were conducted at different temperatures to test the heat transfer performances of grooved MHPs, which were perfused with different inventories and with different adiabatic section lengths. The experimental results show that when the value of α is roughly within 0.40±0.05, a grooved MHP can acquire its best heat transfer performance, and the working fluid inventory can be determined by the proposed mathematic model. Therefore this study solves the complicated problem of determining appropriate working fluid inventory for grooved MHPs.


1993 ◽  
Vol 115 (1) ◽  
pp. 78-88 ◽  
Author(s):  
C. O. Gersey ◽  
I. Mudawar

The effects of chip protrusion on the forced-convection boiling and critical heat flux (CHF) of a dielectric coolant (FC-72) were investigated. The multi-chip module used in the present study featured a linear array of nine, 10 mm x 10 mm, simulated microelectronic chips which protruded 1 mm into a 20-mm wide side of a rectangular flow channel. Experiments were performed in vertical up flow with 5-mm and 2-mm channel gap thicknesses. For each configuration, the velocity and subcooling of the liquid were varied from 13 to 400 cm/s and 3 to 36° C, respectively. The nucleate boiling regime was not affected by changes in velocity and subcooling, and critical heat flux generally increased with increases in either velocity or subcooling. Higher single-phase heat transfer coefficients and higher CHF values were measured for the protruded chips compared to similar flush-mounted chips. However, adjusting the data for the increased surface area and the increased liquid velocity above the chip caused by the protruding chips yielded a closer agreement between the protruded and flush-mounted results. Even with the velocity and area adjustments, the most upstream protruded chip had higher single-phase heat transfer coefficients and CHF values for high velocity and/or highly-subcooled flow as compared the downstream protruded chips. The results show that, except for the most upstream chip, the performances of protruded chips are very similar to those of flush-mounted chips.


Fractals ◽  
2019 ◽  
Vol 27 (07) ◽  
pp. 1950111
Author(s):  
WEI YU ◽  
LUYAO XU ◽  
SHUNJIA CHEN ◽  
FENG YAO

A two-dimensional model is developed to numerically study the water flow boiling through a tree-shaped microchannel by VOF method. In this work, the bubble dynamics and flow patterns along the channel are examined. Additionally, the pressure drop, heat transfer performance and the effects of mass flow rate and heat flux on the heat transfer coefficient are analyzed and discussed. The numerical results indicate that, there are three main bubble dynamic behaviors at the wall, namely coalesce-lift-off, coalesce-slide and coalesce-reattachment. At the bifurcation in high branching level, the slug bubbles may coalesce or breakup. The flow patterns of bubbly, bubbly-slug flows occur at low branching level and slug flow occurs at high branching level. The passage of bubbles causes the increasing of fluid temperature and local pressure. Additionally, the pressure drop decreases with the branching level. The flow pattern and channel confinement effect play a vital role in heat transfer performance. The nucleate boiling dominant heat transfer is observed at low branching level, the heat transfer performance is enhanced with increasing branching level from [Formula: see text] to 2. While, at high branching level, the heat transfer performance becomes weaker due to the suppression of nucleate boiling. Moreover, the heat transfer coefficient increases with the mass flow rate and heat flux.


Author(s):  
Claire M. Kunkle ◽  
Jordan P. Mizerak ◽  
Van P. Carey

The development of hydrophilic surface coatings for enhanced wetting characteristics has led to improvement in heat transfer metrics like impinging droplet vaporization time and the heat transfer coefficient. Hydrothermal synthesis, a method of developing hydrophilic surfaces, has been previously shown to produce high performing heat transfer surfaces on copper substrates [1]. Our study applied this production method to aluminum substrates, which have the advantage of being cheaper, lighter, and a more widely used for heat sinks than copper. Previous experiments have shown that water droplets on ZnO nanostructure coated surfaces, at low superheats, evaporate via thin film evaporation rather than nucleate boiling. This leads to heat transfer coefficients as much as three times higher than nucleate boiling models for the same superheat. Our nanocoated aluminum surfaces exhibit superhydrophilicity with an average droplet liquid film thickness of 20–30 microns, which can produce heat transfer coefficients of over 25 kW/m2K. This study discusses characterization of ZnO nanostructured aluminum surfaces to better understand the related mechanisms which lead to such high heat transfer performance. All ZnO nanostructured aluminum surfaces produced for this study exhibited superhydrophilicity, with sessile droplet contact angles of less than 5 degrees. The challenge of achieving accuracy for such low contact angles led to the development of a new wetting metric related to the droplet’s wetted area on a surface rather than the contact angle. This new metric is predicated on the the fact that heat transfer performance is directly related to this wetted area, thickens, and shape of the expanding droplet footprint. Shape irregularity of droplets on these superhydrophilic surfaces is discussed in this study, where there appears to be advantages to irregular spreading compared with surfaces that produce symmetric radial spreading. One form of irregular spreading consists of liquid droplets spreading out both on top of the surface and within the microstructure of the surface coating. The liquid within the microstructure forms films less than 5 microns thick, making local heat transfer coefficients of greater than 100 kW/m2K possible. SEM microscope imaging provided additional insight to the underlying mechanisms which cause these surfaces to produce such exceptional spreading as well as irregular spreading, resulting in very good heat transfer performance. Experimental work was coupled with computational analysis to model the contact line of the droplet footprint. Image processing of experimental photos helps to analyze spreading characteristics, which can be directly related to heat transfer due to film thickness at various points during spreading. Approaches used to characterize these superhydrophilic surfaces advance understanding of the connections between nanoscale structural elements and macroscale performance characteristics in heat transfer. This understanding can reveal key insights for developing even better high performance surfaces for a broad range of applications.


Author(s):  
Eric A. Browne ◽  
Gregory J. Michna ◽  
Michael K. Jensen ◽  
Yoav Peles

The heat transfer performance of two microjet arrays using degassed deionized water was investigated. The in-line jet arrays had a spacing of 250 μm, a standoff of 200 μm, and diameters of 54 and 112 μm. Average heat transfer coefficients were obtained for 150 &lt; Red &lt; 3300 and ranged from 80,000 to 414,000 W/m2-K. A heat flux of 1,110 W/cm2 was attained with 23 °C water and a surface temperature of 50 °C.


2001 ◽  
Vol 124 (2) ◽  
pp. 383-390 ◽  
Author(s):  
H. Honda ◽  
H. Takamastu ◽  
J. J. Wei

Experiments were conducted to study the effects of micro-pin-fins and submicron-scale roughness on the boiling heat transfer from a silicon chip immersed in a pool of degassed and gas-dissolved FC-72. Square pin-fins with fin dimensions of 50×50×60μm3 (width×thickness×height) and submicron-scale roughness (RMS roughness of 25 to 32 nm) were fabricated on the surface of square silicon chip 10×10×0.5mm3 by use of microelectronic fabrication techniques. Experiments were conducted at the liquid subcoolings of 0, 3, 25, and 45 K. Both the micro-pin-finned chip and the chip with submicron-scale roughness showed a considerable heat transfer enhancement as compared to a smooth chip in the nucleate boiling region. The chip with submicron-scale roughness showed a higher heat transfer performance than the micro-pin-finned chip in the low-heat-flux region. The micro-pin-finned chip showed a steep increase in the heat flux with increasing wall superheat. This chip showed a higher heat transfer performance than the chip with submicron-scale roughness in the high-heat-flux region. The micro-pin-finned chip with submicron-scale roughness on it showed the highest heat transfer performance in the high-heat-flux region. While the wall superheat at boiling incipience was strongly dependent on the dissolved gas content, it was little affected by the liquid subcooling.


2015 ◽  
Vol 137 (7) ◽  
Author(s):  
Maritza Ruiz ◽  
Van P. Carey

This paper presents an experimental study of the heat transfer and pressure drop characteristics of a single phase high heat flux microchannel cooling system with spiraling radial inflow. The heat sink provides enhanced heat transfer with a simple inlet and outlet design while providing uniform flow distribution. The system is heated from one conducting wall made of copper and uses water as a working fluid. The microchannel has a 1 cm radius and a 300 μm gap height. Experimental results show, on average, a 76% larger pressure drop compared to an analytic model for laminar flow in a parallel disk system with spiral radial inflow. The mean heat transfer coefficients measured are up to four times the heat transfer coefficient for unidirectional laminar fully developed flow between parallel plates with the same gap height. Flow visualization studies indicate the presence of secondary flows and the onset of turbulence at higher flow rates. Combined with the thermally developing nature of the flow, these characteristics lead to enhanced heat transfer coefficients relative to the laminar parallel plate values. Another beneficial feature of this device, for high heat flux cooling applications, is that the thermal gradients on the surface are small. The average variation in surface temperature is 18% of the total bulk fluid temperature gain across the device. The system showed promising cooling characteristics for electronics and concentrated photovoltaics applications with a heat flux of 113 W/cm2 at a surface temperature of 77 °C and a ratio of pumping power to heat rate of 0.03%.


Sign in / Sign up

Export Citation Format

Share Document