Thermal and Hydrodynamic Performance of Aqueous CuO and Al2O3 Nanofluids in an Annular Coiled Tube Under Constant Wall Temperature and Laminar Flow Conditions

2016 ◽  
Vol 138 (10) ◽  
Author(s):  
Wael I. A. Aly

Laminar flow and heat transfer behaviors of two different metal oxide, Al2O3 (36 nm) and CuO (29 nm), nanofluids flowing through an annular coiled tube heat exchanger (ACTHE) with constant wall temperature boundary condition have been numerically studied to evaluate their superiority over the base fluid (water). Simulations covered a range of nanoparticles volume concentrations of 1.0–6.0% and mass flow rates from 0.025 to 0.125 kg/s. Numerical results indicated that a considerable heat transfer enhancement is achieved by both nanofluids. Results at the same Reynolds number for the pressure drop and heat transfer coefficient show an increase with increasing particle volumetric concentration. The maximum enhancements in heat transfer coefficient were 44.8% and 18.9% for CuO/water and Al2O3/water, respectively. On the other hand, the pressure loss was seven times in comparison to water for CuO/water and about two times for Al2O3/water nanofluid. Also, comparing to the base fluid, nanofluids at low concentrations (up to 3%) can provide the same heat transfer amount at lower pumping power. The overall performance of the enhanced heat transfer technique utilized has been evaluated using a thermohydrodynamic performance index which indicated that Al2O3/water nanofluid is a better choice than CuO/water nanofluid. Moreover, conventional correlations for helical circular tubes for predicting friction factor and average heat transfer in laminar flow regime such as the correlations of Mori and Nakayam and Manlapaz and Churcill, respectively, are also valid for water and the tested nanofluids with small nanoparticle loading in the ACTHE.

1983 ◽  
Vol 105 (4) ◽  
pp. 878-883 ◽  
Author(s):  
A. Haji-Sheikh ◽  
M. Mashena ◽  
M. J. Haji-Sheikh

An analytical method for the numerical calculation of the heat transfer coefficient in arbitrarily shaped ducts with constant wall temperature at the boundary is presented. The flow is considered to be laminar and fully developed, both thermally and hydrodynamically. The method presented herein makes use of Galerkin-type functions for computation of the Nusselt number. This method is applied to circular pipes and ducts with rectangular, isosceles triangular, and right triangular cross sections. A three-term or even a two-term solution yields accurate solutions for circular ducts. The situation is similar for right triangular ducts with two equal sides. However, for narrower ducts, a larger number of terms must be used.


2021 ◽  
Vol 39 (2) ◽  
pp. 531-540
Author(s):  
Khalid Faisal Sultan ◽  
Mohammed Hassan Jabal ◽  
Ameer Abed Jaddoa

This paper presents an experimental analysis on the heat transfer and pressure drop enhancement of oil nanofluid flow. In this analysis, the first method has used the helically coiled tube and shell, the oil nanofluids were employed instead of the base fluid (oil) in the second process. the two techniques were used to improve the heat transfer and pressure drop. Nanofluid oil concentrations utilized within range from 1 to 5 percent vol. This paper applied two forms of nanoparticles: copper (Cu (20 nm)) and zirconium oxide (ZrO2 (40 nm)) and base fluid (oil). The influence on the heat transfer coefficient for different factors such as the flow number of Reynolds, the temperature of the nanofluid oil, the concentration and shape of the nanoparticle, and the pressure gradient of the flow have examined. The results indicated that the value of a 40.35 percent in the heat transfer coefficient for Cu + oil and 28.42 percent for ZrO2 + oil increased compared with the base fluid (oil) at 5 percent vol concentration. Using oil nanofluids (Cu, ZrO2 – oil) instead of the base fluid (oil) led to increasing in the heat transfer coefficient and decreasing the pressure. In addition, the result showed that the heat transfer efficiency has enhanced using the helically coiled tube and shell, as well as increasing in the pressure drop was due to the curvature of the tube. Baes on the relationship between viscosity and shear intensity, the oil nanofluid behaviors were similar to the standard Newtonian fluids. Moreover, the related flow and heat transfer methods are used to present the output index. The exergy inflow, exergy destruction and exergy efficiency of oil nanofluid (Cu +oil) were greater than the oil nanofluid (ZrO2 +oil) and oil. The exergy inflow, exergy destruction, and exergy efficiency for the two type of oil nanofluid increased with increasing of nanoparticles concentration.


2012 ◽  
Vol 11 (05) ◽  
pp. 1250029 ◽  
Author(s):  
P. C. MUKESH KUMAR ◽  
J. KUMAR ◽  
S. SURESH ◽  
K. PRAVEEN BABU

In this experimental investigation, the heat transfer coefficients of a shell and helically coiled tube heat exchanger using Al2O3 /water nanofluid under laminar flow condition were studied. The Al2O3 nanoparticles were characterized by X-Ray diffraction (XRD). The Al2O3 /water nanofluid at 0.1%, 0.4% and 0.8% particle volume concentration were prepared by using two step method. The prepared nanofluid was characterized by scanning electron microscope (SEM). It is observed that the overall heat transfer coefficient, inner heat transfer coefficient and experimental inner Nusselt number increase while increasing particle volume concentration and increasing inner Dean number. The enhancement of overall heat transfer coefficient was found to be 7%, 16.9% and 24.2% at 0.1%, 0.4% and 0.8% Al2O3 /water nanofluid respectively when compared with water. The enhancement of tube side experimental Nusselt number was found to be 17%, 22.9% and 28% at 0.1%, 0.4% and 0.8% particle volume concentration of Al2O3 /water nanofluid respectively when compared with water at fixed Dean number. The tests were conducted in the range of 1600 < De < 2700, and 5200 < Re < 8600 under laminar flow condition and counter flow configuration. These enhancements are due to higher thermal conductivity of nanofluid while increasing particle volume concentration and Brownian motion of nanoparticles. It is studied that there is no negative impact on formation of secondary flow and mixing of fluid when nanofluid passes through the helically coiled tube.


2021 ◽  
Vol 39 (3) ◽  
pp. 913-918
Author(s):  
Sai Sarath Kruthiventi ◽  
Nandhanagopal Govindha Rasu ◽  
Yarrapathruni V. Hanumanth Rao

In the present study, numerical analysis of coiled tube heat exchanger used in J-T refrigerator is carried out. A computer code is developed to estimate the length of the heat exchanger by giving mass flow rate, diameter of tube and shell as input parameters. This code is verified against experimental data. Two different configurations are considered in this study viz., heat exchanger with wire fin wound around the inner tube of heat exchanger and without wirefin. Three different refrigerant mixtures are used to evaluate the performance of heat exchangers. The variations of temperature and heat transfer coefficient are brought out as result. Significant reduction in the length of heat exchanger is observed in all the cases. Mixture-1 causes 33% reduction in length of heat exchanger with wirefin. Similarly, for mixture-2 and mixture-3 the length is reduced by 15% and 30%. Additionally, heat transfer coefficient (HTC) values are also estimated for heat exchanger with wirefin and without wirefin. Considerable increase in HTC values is observed in the heat exchanger with wirefin.


2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Swanand Gaikwad ◽  
Ashish Parmar

AbstractHeat exchangers possess a significant role in energy transmission and energy generation in most industries. In this work, a three-dimensional simulation has been carried out of a shell and tube heat exchanger (STHX) consisting of segmental baffles. The investigation involves using the commercial code of ANSYS CFX, which incorporates the modeling, meshing, and usage of the Finite Element Method to yield numerical results. Much work is available in the literature regarding the effect of baffle cut and baffle spacing as two different entities, but some uncertainty pertains when we discuss the combination of these two parameters. This study aims to find an appropriate mix of baffle cut and baffle spacing for the efficient functioning of a shell and tube heat exchanger. Two parameters are tested: the baffle cuts at 30, 35, 40% of the shell-inside diameter, and the baffle spacing’s to fit 6,8,10 baffles within the heat exchanger. The numerical results showed the role of the studied parameters on the shell side heat transfer coefficient and the pressure drop in the shell and tube heat exchanger. The investigation shows an increase in the shell side heat transfer coefficient of 13.13% when going from 6 to 8 baffle configuration and a 23.10% acclivity for the change of six baffles to 10, for a specific baffle cut. Evidence also shows a rise in the pressure drop with an increase in the baffle spacing from the ranges of 44–46.79%, which can be controlled by managing the baffle cut provided.


2014 ◽  
Vol 137 (4) ◽  
Author(s):  
Benoit Laveau ◽  
Reza S. Abhari ◽  
Michael E. Crawford ◽  
Ewald Lutum

In order to continue increasing the efficiency of gas turbines, an important effort is made on the thermal management of the turbine stage. In particular, understanding and accurately estimating the thermal loads in a vane passage is of primary interest to engine designers looking to optimize the cooling requirements and ensure the integrity of the components. This paper focuses on the measurement of endwall heat transfer in a vane passage with a three-dimensional (3D) airfoil shape and cylindrical endwalls. It also presents a comparison with predictions performed using an in-house developed Reynolds-Averaged Navier–Stokes (RANS) solver featuring a specific treatment of the numerical smoothing using a flow adaptive scheme. The measurements have been performed in a steady state axial turbine facility on a novel platform developed for heat transfer measurements and integrated to the nozzle guide vane (NGV) row of the turbine. A quasi-isothermal boundary condition is used to obtain both the heat transfer coefficient and the adiabatic wall temperature within a single measurement day. The surface temperature is measured using infrared thermography through small view ports. The infrared camera is mounted on a robot arm with six degrees of freedom to provide high resolution surface temperature and a full coverage of the vane passage. The paper presents results from experiments with two different flow conditions obtained by varying the mass flow through the turbine: measurements at the design point (ReCax=7.2×105) and at a reduced mass flow rate (ReCax=5.2×105). The heat transfer quantities, namely the heat transfer coefficient and the adiabatic wall temperature, are derived from measurements at 14 different isothermal temperatures. The experimental data are supplemented with numerical predictions that are deduced from a set of adiabatic and diabatic simulations. In addition, the predicted flow field in the passage is used to highlight the link between the heat transfer patterns measured and the vortical structures present in the passage.


Author(s):  
Kenneth W. Van Treuren ◽  
Zuolan Wang ◽  
Peter T. Ireland ◽  
Terry V. Jones ◽  
S. T. Kohler

Recent work, Van Treuren et al. (1993), has shown the transient method of measuring heat transfer under an array of impinging jets allows the determination of local values of adiabatic wall temperature and heat transfer coefficient over the complete surface of the target plate. Using this technique, an inline array of impinging jets has been tested over a range of average jet Reynolds numbers (10,000–40,000) and for three channel height to jet hole diameter ratios (1, 2, and 4). The array is confined on three sides and spent flow is allowed to exit in one direction. Local values are averaged and compared with previously published data in related geometries. The current data for a staggered array is compared to those from an inline array with the same hole diameter and pitch for an average jet Reynolds number of 10,000 and channel height to diameter ratio of one. A comparison is made between intensity and hue techniques for measuring stagnation point and local distributions of heat transfer. The influence of the temperature of the impingement plate through which the coolant gas flows on the target plate heat transfer has been quantified.