Effect of Low-NOX Combustor Swirl Clocking on Intermediate Turbine Duct Vane Aerodynamics With an Upstream High Pressure Turbine Stage—An Experimental and Computational Study

2016 ◽  
Vol 139 (1) ◽  
Author(s):  
Martin Johansson ◽  
Thomas Povey ◽  
Kam Chana ◽  
Hans Abrahamsson

Flow in an intermediate turbine duct (ITD) is highly complex, influenced by the upstream turbine stage flow structures, which include tip leakage flow and nonuniformities originating from the upstream high pressure turbine (HPT) vane and rotor. The complexity of the flow structures makes predicting them using numerical methods difficult, hence there exists a need for experimental validation. To evaluate the flow through an intermediate turbine duct including a turning vane, experiments were conducted in the Oxford Turbine Research Facility (OTRF). This is a short duration high speed test facility with a 3/4 engine-sized turbine, operating at the correct nondimensional parameters for aerodynamic and heat transfer measurements. The current configuration consists of a high pressure turbine stage and a downstream duct including a turning vane, for use in a counter-rotating turbine configuration. The facility has the ability to simulate low-NOx combustor swirl at the inlet to the turbine stage. This paper presents experimental aerodynamic results taken with three different turbine stage inlet conditions: a uniform inlet flow and two low-NOx swirl profiles (different clocking positions relative to the high pressure turbine vane). To further explain the flow through the 1.5 stage turbine, results from unsteady computational fluid dynamics (CFD) are included. The effect of varying the high pressure turbine vane inlet condition on the total pressure field through the 1.5 stage turbine, the intermediate turbine duct vane loading, and intermediate turbine duct exit condition are discussed and CFD results are compared with experimental data. The different inlet conditions are found to alter the flow exiting the high pressure turbine rotor. This is seen to have local effects on the intermediate turbine duct vane. With the current stator–stator vane count of 32-24, the effect of relative clocking between the two is found to have a larger effect on the aerodynamics in the intermediate turbine duct than the change in the high pressure turbine stage inlet condition. Given the severity of the low-NOx swirl profiles, this is perhaps surprising.

Author(s):  
Chaoshan Hou ◽  
Hu Wu

The flow leaving the high pressure turbine should be guided to the low pressure turbine by an annular diffuser, which is called as the intermediate turbine duct. Flow separation, which would result in secondary flow and cause great flow loss, is easily induced by the negative pressure gradient inside the duct. And such non-uniform flow field would also affect the inlet conditions of the low pressure turbine, resulting in efficiency reduction of low pressure turbine. Highly efficient intermediate turbine duct cannot be designed without considering the effects of the rotating row of the high pressure turbine. A typical turbine model is simulated by commercial computational fluid dynamics method. This model is used to validate the accuracy and reliability of the selected numerical method by comparing the numerical results with the experimental results. An intermediate turbine duct with eight struts has been designed initially downstream of an existing high pressure turbine. On the basis of the original design, the main purpose of this paper is to reduce the net aerodynamic load on the strut surface and thus minimize the overall duct loss. Full three-dimensional inverse method is applied to the redesign of the struts. It is revealed that the duct with new struts after inverse design has an improved performance as compared with the original one.


Author(s):  
Charles W. Haldeman ◽  
Michael G. Dunn ◽  
John W. Barter ◽  
Brian R. Green ◽  
Robert F. Bergholz

Aerodynamic measurements were acquired on a modern single-stage, transonic, high-pressure turbine with the adjacent low-pressure turbine vane row (a typical civilian one and one-half stage turbine rig) to observe the effects of low-pressure turbine vane clocking on overall turbine performance. The turbine rig (loosely referred to in this paper as the stage) was operated at design corrected conditions using the Ohio State University Gas Turbine Laboratory Turbine Test Facility (TTF). The research program utilized uncooled hardware in which all three airfoils were heavily instrumented at multiple spans to develop a full clocking dataset. The low-pressure turbine vane row (LPTV) was clocked relative to the high-pressure turbine vane row (HPTV). Various methods were used to evaluate the influence of clocking on the aeroperformance (efficiency) and the aerodynamics (pressure loading) of the LPTV, including time-resolved and time-averaged measurements. A change in overall efficiency of approximately 2–3% due to clocking effects is demonstrated and could be observed using a variety of independent methods. Maximum efficiency is obtained when the time-average surface pressures are highest on the LPTV and the time-resolved surface pressure (both in the time domain and frequency domain) show the least amount of variation. The overall effect is obtained by integrating over the entire airfoil, as the three-dimensional effects on the LPTV surface are significant. This experimental data set validates several computational research efforts that suggested wake migration is the primary reason for the perceived effectiveness of vane clocking. The suggestion that wake migration is the dominate mechanism in generating the clocking effect is also consistent with anecdotal evidence that fully cooled engine rigs do not see a great deal of clocking effect. This is consistent since the additional disturbances induced by the cooling flows and/or the combustor make it extremely difficult to find an alignment for the LPTV given the strong 3D nature of modern high-pressure turbine flows.


Author(s):  
Simon Gövert ◽  
Federica Ferraro ◽  
Alexander Krumme ◽  
Clemens Buske ◽  
Marc Tegeler ◽  
...  

Abstract Reducing the uncertainties in the prediction of turbine inlet conditions is a crucial aspect to improve aero engine designs and further increase engine efficiencies. To meet constantly stricter emission regulations, lean burn combustion could play a key role for future engine designs. However, these combustion systems are characterized by significant swirl for flame stabilization and reduced cooling air mass flows. As a result, substantial spatial and transient variations of the turbine inlet conditions are encountered. To investigate the effect of the combustor on the high pressure turbine, a rotating cooled transonic high-pressure configuration has been designed and investigated experimentally at the DLR turbine test facility ‘NG-Turb’ in Göttingen, Germany. It is a rotating full annular 1.5 stage turbine configuration which is coupled to a combustor simulator. The combustor simulator is designed to create turbine inlet conditions which are hydrodynamically representative for a lean-burn aero engine. A detailed description of the test rig and its instrumentation as well as a discussion of the measurement results is presented in part I of this paper. Part II focuses on numerical modeling of the test rig to further extend the understanding of the measurement results. Integrated simulations of the configuration including combustor simulator and nozzle guide vanes are performed for leading edge and passage clocking position and the effect on the hot streak migration is discussed. The simulation and experimental results at the combustor-turbine interface are compared showing a good overall agreement. The relevant flow features are correctly predicted in the simulations, proving the suitability of the numerical model for application to integrated combustor-turbine interaction analysis.


Author(s):  
Milind A. Bakhle ◽  
Jong S. Liu ◽  
Josef Panovsky ◽  
Theo G. Keith ◽  
Oral Mehmed

Forced vibrations in turbomachinery components can cause blades to crack or fail due to high-cycle fatigue. Such forced response problems will become more pronounced in newer engines with higher pressure ratios and smaller axial gap between blade rows. An accurate numerical prediction of the unsteady aerodynamics phenomena that cause resonant forced vibrations is increasingly important to designers. Validation of the computational fluid dynamics (CFD) codes used to model the unsteady aerodynamic excitations is necessary before these codes can be used with confidence. Recently published benchmark data, including unsteady pressures and vibratory strains, for a high-pressure turbine stage makes such code validation possible. In the present work, a three dimensional, unsteady, multi blade-row, Reynolds-Averaged Navier Stokes code is applied to a turbine stage that was recently tested in a short duration test facility. Two configurations with three operating conditions corresponding to modes 2, 3, and 4 crossings on the Campbell diagram are analyzed. Unsteady pressures on the rotor surface are compared with data.


2004 ◽  
Vol 127 (3) ◽  
pp. 512-521 ◽  
Author(s):  
Charles W. Haldeman ◽  
Michael Dunn ◽  
John W. Barter ◽  
Brian R. Green ◽  
Robert F. Bergholz

Aerodynamic measurements were acquired on a modern single-stage, transonic, high-pressure turbine with the adjacent low-pressure turbine vane row (a typical civilian one and one-half stage turbine rig) to observe the effects of low-pressure turbine vane clocking on overall turbine performance. The turbine rig (loosely referred to in this paper as the stage) was operated at design corrected conditions using the Ohio State University Gas Turbine Laboratory Turbine Test Facility. The research program utilized uncooled hardware in which all three airfoils were heavily instrumented at multiple spans to develop a full clocking dataset. The low-pressure turbine vane row (LPTV) was clocked relative to the high-pressure turbine vane row (HPTV). Various methods were used to evaluate the influence of clocking on the aeroperformance (efficiency) and the aerodynamics (pressure loading) of the LPTV, including time-resolved and time-averaged measurements. A change in overall efficiency of approximately 2–3% due to clocking effects is demonstrated and could be observed using a variety of independent methods. Maximum efficiency is obtained when the time-average surface pressures are highest on the LPTV and the time-resolved surface pressure (both in the time domain and frequency domain) show the least amount of variation. The overall effect is obtained by integrating over the entire airfoil, as the three-dimensional (3D) effects on the LPTV surface are significant. This experimental data set validates several computational research efforts that suggested wake migration is the primary reason for the perceived effectiveness of vane clocking. The suggestion that wake migration is the dominate mechanism in generating the clocking effect is also consistent with anecdotal evidence that fully cooled engine rigs do not see a great deal of clocking effect. This is consistent since the additional disturbances induced by the cooling flows and∕or the combustor make it extremely difficult to find an alignment for the LPTV given the strong 3D nature of modern high-pressure turbine flows.


2004 ◽  
Vol 10 (6) ◽  
pp. 495-506 ◽  
Author(s):  
Roger L. Davis ◽  
Jixian Yao ◽  
John P. Clark ◽  
Gary Stetson ◽  
Juan J. Alonso ◽  
...  

Results from a numerical simulation of the unsteady flow through one quarter of the circumference of a transonic high-pressure turbine stage, transition duct, and low-pressure turbine first vane are presented and compared with experimental data. Analysis of the unsteady pressure field resulting from the simulation shows the effects of not only the rotor/stator interaction of the high-pressure turbine stage but also new details of the interaction between the blade and the downstream transition duct and low-pressure turbine vane. Blade trailing edge shocks propagate downstream, strike, and reflect off of the transition duct hub and/or downstream vane leading to high unsteady pressure on these downstreamcomponents. The reflection of these shocks from the downstream components back into the blade itself has also been found to increase the level of unsteady pressure fluctuations on the uncovered portion of the blade suction surface. In addition, the blade tip vortex has been found to have a moderately strong interaction with the downstream vane even with the considerable axial spacing between the two blade-rows. Fourier decomposition of the unsteady surface pressure of the blade and downstream low-pressure turbine vane shows the magnitude of the various frequencies contributing to the unsteady loads. Detailed comparisons between the computed unsteady surface pressure spectrum and the experimental data are shown along with a discussion of the various interaction mechanisms between the blade, transition duct, and downstream vane. These comparisons show-overall good agreement between the simulation and experimental data and identify areas where further improvements in modeling are needed.


2009 ◽  
Vol 131 (3) ◽  
Author(s):  
C. W. Haldeman ◽  
M. G. Dunn ◽  
S. A. Southworth ◽  
J.-P. Chen ◽  
G. Heitland ◽  
...  

The aerodynamics of a fully cooled, axial, single stage high-pressure turbine operating at design corrected conditions of corrected speed, flow function, and stage pressure ratio has been investigated experimentally and computationally and presented in Part I of this paper. In that portion of the paper, flow-field predictions obtained using the computational fluid dynamics codes Numeca’s FINE/TURBO and the code TURBO were obtained using different design methodologies that approximated the fully-cooled turbine stage in different ways. These predictions were compared to measurements obtained using the Ohio State University Gas Turbine Laboratory Turbine Test Facility, in a process that was essentially a design methodology validation study, instead of a computational methodology optimization study. The difference between the two is that the designers were given one chance to use their codes (as a designer would normally do) instead of using the existing data to fine-tune their grids/methodologies by doing grid studies and changes in the turbulence models employed. Part I of this paper showed differing results from the two solvers, which appeared to be mainly dependent on the differences in grid resolution and/or modeling features selected by the code users. Examining these occurrences points to places where the design methodology could be improved, but it became clear that metrics were needed to compare overall performance of each approach. In this part of the paper, three criteria are proposed for measuring overall prediction quality of the unsteady predictions, which include the unsteady envelope size, envelope shape, and power spectrum. These measures capture the main characteristics of the unsteady data and allow designers to use the criteria of most interest to them. In addition, these can be used to track how well predictions improve over time as grid resolutions and modeling techniques change.


2006 ◽  
Vol 129 (3) ◽  
pp. 572-579 ◽  
Author(s):  
P. Gaetani ◽  
G. Persico ◽  
V. Dossena ◽  
C. Osnaghi

An extensive experimental analysis on the subject of unsteady flow field in high-pressure turbine stages was carried out at the Laboratorio di Fluidodinamica delle Macchine (LFM) of Politecnico di Milano. The research stage represents a typical modern HP gas turbine stage designed by means of three-dimensional (3D) techniques, characterized by a leaned stator and a bowed rotor and operating in high subsonic regime. The first part of the program concerns the analysis of the steady flow field in the stator-rotor axial gap by means of a conventional five-hole probe and a temperature sensor. Measurements were carried out on eight planes located at different axial positions, allowing the complete definition of the three-dimensional flow field both in absolute and relative frame of reference. The evolution of the main flow structures, such as secondary flows and vane wakes, downstream of the stator are here presented and discussed in order to evidence the stator aerodynamic performance and, in particular, the different flow field approaching the rotor blade row for the two axial gaps. This results set will support the discussion of the unsteady stator-rotor effects presented in Part II (Gaetani, P., Persico, G., Dossena, V., and Osnaghi, C., 2007, ASME J. Turbomach., 129(3), pp. 580–590). Furthermore, 3D time-averaged measurements downstream of the rotor were carried out at one axial distance and for two stator-rotor axial gaps. The position of the probe with respect to the stator blades is changed by rotating the stator in circumferential direction, in order to describe possible effects of the nonuniformity of the stator exit flow field downstream of the stage. Both flow fields, measured for the nominal and for a very large stator-rotor axial gap, are discussed, and results show the persistence of some stator flow structures downstream of the rotor, in particular, for the minimum axial gap. Finally, the flow fields are compared to evidence the effect of the stator-rotor axial gap on the stage performance from a time-averaged point of view.


Author(s):  
Roger L. Davis ◽  
Jixian Yao ◽  
John P. Clark ◽  
Gary Stetson ◽  
Juan J. Alonso ◽  
...  

Results from a numerical simulation of the unsteady flow through one quarter of the circumference of a transonic high-pressure turbine stage, transition duct, and low-pressure turbine first vane are presented and compared with experimental data. Analysis of the unsteady pressure field resulting from the simulation shows the effects of not only the rotor/stator interaction of the high-pressure turbine stage but also new details of the interaction between the blade and the downstream transition duct and low-pressure turbine vane. Blade trailing edge shocks propagate downstream, strike, and reflect off of the transition duct hub and/or downstream vane leading to high unsteady pressure on these downstream components. The reflection of these shocks from the downstream components back into the blade itself has also been found to increase the level of unsteady pressure fluctuations on the uncovered portion of the blade suction surface. In addition, the blade tip vortex has been found to have a moderately strong interaction with the downstream vane even with the considerable axial spacing between the two blade-rows. Fourier decomposition of the unsteady surface pressure of the blade and downstream low-pressure turbine vane shows the magnitude of the various frequencies contributing to the unsteady loads. Detailed comparisons between the computed unsteady surface pressure spectrum and the experimental data are shown along with a discussion of the various interaction mechanisms between the blade, transition duct, and downstream vane. These comparisons show overall good agreement between the simulation and experimental data and identify areas where further improvements in modeling are needed.


Sign in / Sign up

Export Citation Format

Share Document