Comparison of RANS and Detached Eddy Simulation Modeling Against Measurements of Leading Edge Film Cooling on a First-Stage Vane

2017 ◽  
Vol 139 (5) ◽  
Author(s):  
S. Ravelli ◽  
G. Barigozzi

The performance of a showerhead arrangement of film cooling in the leading edge region of a first-stage nozzle guide vane was experimentally and numerically evaluated. A six-vane linear cascade was tested at an isentropic exit Mach number of Ma2s = 0.42, with a high inlet turbulence intensity level of 9%. The showerhead cooling scheme consists of four staggered rows of cylindrical holes evenly distributed around the stagnation line, angled at 45 deg toward the tip. The blowing ratios tested are BR = 2.0, 3.0, and 4.0. Adiabatic film cooling effectiveness distributions on the vane surface around the leading edge region were measured by means of thermochromic liquid crystals (TLC) technique. Since the experimental contours of adiabatic effectiveness showed that there is no periodicity across the span, the computational fluid dynamics (CFD) calculations were conducted by simulating the whole vane. Within the Reynolds-averaged Navier–Stokes (RANS) framework, the very widely used realizable k–ε (Rke) and the shear stress transport k–ω (SST) turbulence models were chosen for simulating the effect of the BR on the surface distribution of adiabatic effectiveness. The turbulence model which provided the most accurate steady prediction, i.e., Rke, was selected for running detached eddy simulation (DES) at the intermediate value of BR = 3. Fluctuations of the local temperature were computed by DES, due to the vortex structures within the shear layers between the main flow and the coolant jets. Moreover, mixing was enhanced both in the wall-normal and spanwise directions, compared to RANS modeling. DES roughly halved the prediction error of laterally averaged film cooling effectiveness on the suction side of the leading edge. However, neither DES nor RANS provided the expected decay of effectiveness progressing downstream along the pressure side, with 15% overestimation of ηav at s/C = 0.2.

Author(s):  
S. Ravelli ◽  
G. Barigozzi

The performance of a showerhead arrangement of film cooling in the leading edge region of a first stage nozzle guide vane was experimentally and numerically evaluated. A six-vane linear cascade was tested at an isentropic exit Mach number of Ma2s = 0.42, with a high inlet turbulence intensity level of 9%. The showerhead cooling scheme consists of four staggered rows of cylindrical holes evenly distributed around the stagnation line, angled at 45° towards the tip. The blowing ratios tested are BR = 2.0, 3.0 and 4.0. Adiabatic film cooling effectiveness distributions on the vane surface around the leading edge region were measured by means of Thermochromic Liquid Crystals technique. Since the experimental contours of adiabatic effectiveness showed that there is no periodicity across the span, the CFD calculations were conducted by simulating the whole vane. Within the RANS framework, the very widely used Realizable k-ε (Rke) and the Shear Stress Transport k-ω (SST) turbulence models were chosen for simulating the effect of the BR on the surface distribution of adiabatic effectiveness. The turbulence model which provided the most accurate steady prediction, i.e. Rke, was selected for running Detached Eddy Simulation at the intermediate value of BR = 3. Fluctuations of the local temperature were computed by DES, due to the vortex structures within the shear layers between the main flow and the coolant jets. Moreover, mixing was enhanced both in the wall-normal and spanwise direction, compared to RANS modeling. DES roughly halved the prediction error of laterally averaged film cooling effectiveness on the suction side of the leading edge. However, neither DES nor RANS provided the expected decay of effectiveness progressing downstream along the pressure side, with 15% overestimation of ηav at s/C =0.2.


Author(s):  
Pingfan He ◽  
Dragos Licu ◽  
Martha Salcudean ◽  
Ian S. Gartshore

The effect of varying coolant density on film cooling effectiveness for a turbine blade-model was numerically investigated and compared with experimental data. This model had a semi-circular leading edge with four rows of laterally-inclined film cooling orifices positioned symmetrically about the stagnation line. A curvilinear coordinate-based CFD code was developed and used for the numerical investigation. The code used a domain segmentation strategy in conjunction with general curvilinear grids to model the complex blade configuration. A multigrid method was used to accelerate the convergence rate. The time-averaged, variable-density, Navier-Stokes equations together with the energy or scalar equation were solved. Turbulence closure was attained by the standard k–ε model with a near-wall k model. Either air or CO2 was used as coolant in three cases of injection through single rows and alternatively staggered double raws of holes. Two different blowing rates were investigated in each case and compared with experimental data. The experimental results were obtained using a wind tunnel model, and the mass/heat analogy was used to determine the film cooling effectiveness. The higher density of the carbon dioxide coolant (approximately 1.5 times the density of air) in the isothermal mass injection experiments, was used to simulate the effects of injection of a colder air in the corresponding adiabatic heat transfer situation. Good agreement between calculated and measured film cooling effectiveness was found for low blowing ratio M ≤ 0.5 and the effect of density was not significant. At higher blowing ratio M > 1 the calculations consistently overpredict the measured values of film cooling effectiveness.


2006 ◽  
Vol 128 (9) ◽  
pp. 879-888 ◽  
Author(s):  
Jaeyong Ahn ◽  
M. T. Schobeiri ◽  
Je-Chin Han ◽  
Hee-Koo Moon

Detailed film cooling effectiveness distributions are measured on the leading edge of a rotating gas turbine blade with two rows (pressure-side row and suction-side row from the stagnation line) of holes aligned to the radial axis using the pressure sensitive paint (PSP) technique. Film cooling effectiveness distributions are obtained by comparing the difference of the measured oxygen concentration distributions with air and nitrogen as film cooling gas respectively and by applying the mass transfer analogy. Measurements are conducted on the first-stage rotor blade of a three-stage axial turbine at 2400rpm (positive off-design), 2550rpm (design), and 3000rpm (negative off-design), respectively. The effect of three blowing ratios is also studied. The blade Reynolds number based on the axial chord length and the exit velocity is 200,000 and the total to exit pressure ratio was 1.12 for the first-stage rotor blade. The corresponding rotor blade inlet and outlet Mach numbers are 0.1 and 0.3, respectively. The film cooling effectiveness distributions are presented along with discussions on the influence of rotational speed (off design incidence angle), blowing ratio, and upstream nozzle wakes around the leading edge region. Results show that rotation has a significant impact on the leading edge film cooling distributions with the average film cooling effectiveness in the leading edge region decreasing with an increase in the rotational speed (negative incidence angle).


Author(s):  
M. Salcudean ◽  
I. Gartshore ◽  
K. Zhang ◽  
Y. Barnea

Experiments have been conducted on a large model of a turbine blade. Attention has been focussed on the leading edge region, which has a semi-circular shape and four rows of film cooling holes positioned symmetrically about the stagnation line. The cooling holes were oriented in a spanwise direction with an inclination of 30° to the surface, and had streamwise locations of ±15° and ±44° from the stagnation line. Film cooling effectiveness was measured using a heat/mass analogy. Single row cooling from the holes at 15° and 44° showed similar patterns: spanwise averaged effectiveness which rises from zero at zero coolant mass flow to a maximum value η* at some value of mass flow ratio M*, then drops to low values of η at higher M. The trends can be quantitatively explained from simple momentum considerations for either air or CO2 as the coolant gas. Close to the holes, air provides higher η values for small M. At higher M, particularly farther downstream, the CO2 may be superior. The use of an appropriately defined momentum ratio G collapses the data from both holes using either CO2 or air as coolant onto a single curve. For η*, the value of G for all data is about 0.1. Double row cooling with air as coolant shows that the relative stagger of the two rows is an important parameter. Holes in line with each other in successive rows can provide improvements in spanwise averaged film cooling effectiveness of as much as 100% over the common staggered arrangement. This improvement is due to the interaction between coolant from rows one and two, which tends to provide complete coverage of the downstream surface when the rows are placed correctly with respect to each other.


2014 ◽  
Vol 554 ◽  
pp. 317-321
Author(s):  
Mohamad Rasidi Bin Pairan ◽  
Norzelawati Binti Asmuin ◽  
Hamidon bin Salleh

Film cooling is one of the cooling techniques applied to the turbine blade. Gas turbine used film cooling technique to protect turbine blade from directly expose to the hot gas to avoid the blade from defect. The focus of this investigation is to investigate the effect of embedded three difference depth of trench at coolant holes geometry. Comparisons are made at four difference blowing ratios which are 1.0, 1.25 and 1.5. Three configuration leading edge with depth Case A (0.0125D), Case B (0.0350D) and Case C (0.713D) were compared to leading edge without trench. Result shows that as blowing ratio increased from 1.0 to 1.25, the film cooling effectiveness is increase for leading edge without trench and also for all cases. However when the blowing ratio is increase to 1.5, film cooling effectiveness is decrease for all cases. Overall the Case B with blowing ratio 1.25 has the best film cooling effectiveness with significant improvement compared to leading edge without trench and with trench Case A and Case C.


2011 ◽  
Vol 134 (3) ◽  
Author(s):  
Toshihiko Takahashi ◽  
Ken-ichi Funazaki ◽  
Hamidon Bin Salleh ◽  
Eiji Sakai ◽  
Kazunori Watanabe

This paper describes the assessment of CFD simulations for the film cooling on the blade leading edge with circular cooling holes in order to contribute durability assessment of the turbine blades. Unsteady RANS applying a k-ε-v2-f turbulence model and the Spalart and Allmaras turbulence model and detached-eddy simulation (DES) based on the Spalart and Allmaras turbulence model are addressed to solve thermal convection. The CFD calculations were conducted by simulating a semicircular model in the wind tunnel experiments. The DES and also the k-ε-v2-f model evaluate explicitly the unsteady fluctuation of local temperature by the vortex structures, so that the predicted film cooling effectiveness is comparatively in agreement with the measurements. On the other hand, the predicted temperature fields by the Spalart and Allmaras model are less diffusive than the DES and the k-ε-v2-f model. In the present turbulence modeling, the DES only predicts the penetration of main flow into the film cooling hole but the Spalart and Allmaras model is not able to evaluate the unsteadiness and the vortex structures clearly, and overpredict film cooling effectiveness on the partial surface.


Author(s):  
G. Barigozzi ◽  
H. Abdeh ◽  
A. Perdichizzi ◽  
M. Henze ◽  
J. Krueckels

In the present paper, the influence of the presence of an inlet flow non uniformity on the aerodynamic and thermal performance of a film cooled linear nozzle vane cascade is fully assessed. Tests have been carried out with platform cooling, with coolant ejected through a slot located upstream of the leading edge. Cooling air is also ejected through a row of cylindrical holes located upstream of the slot, simulating a combustor cooling system. An obstruction was installed upstream of the cascade at variable tangential and axial position to generate a flow non uniformity. The cascade was tested at a high inlet turbulence intensity level (Tu1 = 9%) and at a constant inlet Mach number of 0.12 and nominal cooling condition. Aero-thermal characterization of vane platform was obtained through 5-hole probe and end wall adiabatic film cooling effectiveness measurements. Results show a relevant negative impact of inlet flow non uniformity on the cooled cascade aerodynamic and thermal performance. Higher film cooling effectiveness and lower aerodynamic losses are obtained when the inlet flow non uniformity is located at mid pitch, while lower effectiveness and higher losses are obtained when it is aligned to the vane leading edge. Moving the non uniformity axially or changing its blockage only marginally influences the platform thermal protection.


Author(s):  
Ian S. Gartshore ◽  
Marthe Salcudean ◽  
Y. Barnea ◽  
K. Zhang ◽  
F. Aghadsi

Experiments have been conducted on a large wind tunnel model of the leading edge region of a turbine blade. The model had a semi-circular leading edge in which four rows of holes were symmetrically placed about the stagnation line, two at ±15° and two at ±44°. Air and alternatively CO2 were injected from the coolant holes after contamination with a known small percentage of propane. Using a flame ionization detector and the mass transfer analogy, the film cooling effectiveness was measured at various overall mass flow ratios and at various streamwise locations for each coolant type. The division of coolant flow rate from the two rows of holes was found to be more unequal for CO2 than for air, an effect which is predicted from a simple analysis of the coolant/free stream interaction and the hole discharge coefficient. This has practical implications for actual turbine operation since earlier cut-off of the coolant from the front row of holes, due to density differences, could have disastrous effects on the blade. This effect also further complicates any attempt to identify overall trends of coolant density on performance. It is not possible to conclude that air or CO2 coolant has a higher film cooling effectiveness, although, in general, air appears better close to the first row of holes, and CO2 better at some distance downstream of both rows. Based on the measurements, the effects of mass flow ratio, momentum flux ratio, relative hole placement in each row, and spanwise versus streamwise injection are discussed in the paper.


Author(s):  
Jaeyong Ahn ◽  
M. T. Schobeiri ◽  
Je-Chin Han ◽  
Hee-Koo Moon

Detailed film cooling effectiveness distributions were measured on the leading edge region of a rotating blade using a Pressure Sensitive Paint technique. The film cooling effectiveness information was obtained from the oxygen concentration difference between air and nitrogen or air and CO2 injection cases by applying the mass transfer analogy. The blowing ratio was controlled to be 0.5, 1.0, and 2.0 while the density ratios of 1.0 and 1.5 were obtained using nitrogen and CO2 as coolant gases, respectively. Tests were conducted on the first stage rotor of a 3-stage axial turbine at 2400, 2550, and 3000 rpm. The Reynolds number based on the axial chord length and the exit velocity was 200,000 and the total to exit pressure ratio was 1.12 for the first rotor. The film cooling effectiveness distributions were presented along with the discussions on the influences of blowing ratio, density ratio, and vortices around the leading edge region at different rotational speeds.


Author(s):  
Shantanu Mhetras ◽  
Je-Chin Han ◽  
Ron Rudolph

The effect of film cooling holes placed along the span of a fully-cooled high pressure turbine blade in a stationary, linear cascade on film cooling effectiveness is studied using the Pressure Sensitive Paint (PSP) technique. Effect of showerhead injection at the leading edge and the presence of compound angled, diffusing holes on the pressure and suction side are also examined. Six rows of compound angled shaped film cooling holes are provided on the pressure side while four such rows are provided on the suction side of the blade. The holes have a laidback and fan-shaped diffusing cross-section. Another three rows of cylindrical holes are drilled at a typical angle on the leading edge to capture the effect of showerhead film coolant injection. The film cooling hole arrangement simulates a typical film cooled blade design used in stage 1 rotor blades for gas turbines used for power generation. A typical blowing ratio is defined for each film hole row and tests are performed for 100%, 150% and 200% of this typical value. Tests are performed for inlet Mach numbers of 0.36 and 0.45 with corresponding exit Mach numbers of 0.51 and 0.68 respectively. The flow remains subsonic in the throat region for both Mach numbers. The corresponding free stream Reynolds number, based on the axial chord length and the exit velocity, are 1.3 million and 1.74 million respectively. Freestream turbulence intensity level at the cascade inlet is 6%. Results show that varying blowing ratios can have a significant impact on film-cooling effectiveness distribution. Large spanwise variations in effectiveness distributions are also observed. Similar distributions were observed for both Mach numbers.


Sign in / Sign up

Export Citation Format

Share Document