Comparison of RANS and DES Modeling Against Measurements of Leading Edge Film Cooling on a First-Stage Vane

Author(s):  
S. Ravelli ◽  
G. Barigozzi

The performance of a showerhead arrangement of film cooling in the leading edge region of a first stage nozzle guide vane was experimentally and numerically evaluated. A six-vane linear cascade was tested at an isentropic exit Mach number of Ma2s = 0.42, with a high inlet turbulence intensity level of 9%. The showerhead cooling scheme consists of four staggered rows of cylindrical holes evenly distributed around the stagnation line, angled at 45° towards the tip. The blowing ratios tested are BR = 2.0, 3.0 and 4.0. Adiabatic film cooling effectiveness distributions on the vane surface around the leading edge region were measured by means of Thermochromic Liquid Crystals technique. Since the experimental contours of adiabatic effectiveness showed that there is no periodicity across the span, the CFD calculations were conducted by simulating the whole vane. Within the RANS framework, the very widely used Realizable k-ε (Rke) and the Shear Stress Transport k-ω (SST) turbulence models were chosen for simulating the effect of the BR on the surface distribution of adiabatic effectiveness. The turbulence model which provided the most accurate steady prediction, i.e. Rke, was selected for running Detached Eddy Simulation at the intermediate value of BR = 3. Fluctuations of the local temperature were computed by DES, due to the vortex structures within the shear layers between the main flow and the coolant jets. Moreover, mixing was enhanced both in the wall-normal and spanwise direction, compared to RANS modeling. DES roughly halved the prediction error of laterally averaged film cooling effectiveness on the suction side of the leading edge. However, neither DES nor RANS provided the expected decay of effectiveness progressing downstream along the pressure side, with 15% overestimation of ηav at s/C =0.2.

2017 ◽  
Vol 139 (5) ◽  
Author(s):  
S. Ravelli ◽  
G. Barigozzi

The performance of a showerhead arrangement of film cooling in the leading edge region of a first-stage nozzle guide vane was experimentally and numerically evaluated. A six-vane linear cascade was tested at an isentropic exit Mach number of Ma2s = 0.42, with a high inlet turbulence intensity level of 9%. The showerhead cooling scheme consists of four staggered rows of cylindrical holes evenly distributed around the stagnation line, angled at 45 deg toward the tip. The blowing ratios tested are BR = 2.0, 3.0, and 4.0. Adiabatic film cooling effectiveness distributions on the vane surface around the leading edge region were measured by means of thermochromic liquid crystals (TLC) technique. Since the experimental contours of adiabatic effectiveness showed that there is no periodicity across the span, the computational fluid dynamics (CFD) calculations were conducted by simulating the whole vane. Within the Reynolds-averaged Navier–Stokes (RANS) framework, the very widely used realizable k–ε (Rke) and the shear stress transport k–ω (SST) turbulence models were chosen for simulating the effect of the BR on the surface distribution of adiabatic effectiveness. The turbulence model which provided the most accurate steady prediction, i.e., Rke, was selected for running detached eddy simulation (DES) at the intermediate value of BR = 3. Fluctuations of the local temperature were computed by DES, due to the vortex structures within the shear layers between the main flow and the coolant jets. Moreover, mixing was enhanced both in the wall-normal and spanwise directions, compared to RANS modeling. DES roughly halved the prediction error of laterally averaged film cooling effectiveness on the suction side of the leading edge. However, neither DES nor RANS provided the expected decay of effectiveness progressing downstream along the pressure side, with 15% overestimation of ηav at s/C = 0.2.


Author(s):  
M. Salcudean ◽  
I. Gartshore ◽  
K. Zhang ◽  
Y. Barnea

Experiments have been conducted on a large model of a turbine blade. Attention has been focussed on the leading edge region, which has a semi-circular shape and four rows of film cooling holes positioned symmetrically about the stagnation line. The cooling holes were oriented in a spanwise direction with an inclination of 30° to the surface, and had streamwise locations of ±15° and ±44° from the stagnation line. Film cooling effectiveness was measured using a heat/mass analogy. Single row cooling from the holes at 15° and 44° showed similar patterns: spanwise averaged effectiveness which rises from zero at zero coolant mass flow to a maximum value η* at some value of mass flow ratio M*, then drops to low values of η at higher M. The trends can be quantitatively explained from simple momentum considerations for either air or CO2 as the coolant gas. Close to the holes, air provides higher η values for small M. At higher M, particularly farther downstream, the CO2 may be superior. The use of an appropriately defined momentum ratio G collapses the data from both holes using either CO2 or air as coolant onto a single curve. For η*, the value of G for all data is about 0.1. Double row cooling with air as coolant shows that the relative stagger of the two rows is an important parameter. Holes in line with each other in successive rows can provide improvements in spanwise averaged film cooling effectiveness of as much as 100% over the common staggered arrangement. This improvement is due to the interaction between coolant from rows one and two, which tends to provide complete coverage of the downstream surface when the rows are placed correctly with respect to each other.


Author(s):  
G. Barigozzi ◽  
S. Ravelli

In this paper showerhead film cooling performance measured on a first stage nozzle guide vane within a linear cascade are presented and compared against steady and unsteady CFD simulations. A showerhead cooling scheme was tested at blowing ratios of BR = 2 to 4 under engine-like conditions (i.e. nominal exit Mach number of Ma2is = 0.42 and high mainstream turbulence level). Adiabatic film cooling effectiveness in the leading edge region was measured by means of wide banded Thermochromic Liquid Crystals. A borescope was used to overcome the constraints to the optical access imposed by the turbulence generator. Moreover, exit surveys detailing total pressure downstream of the cooled vane were acquired using a five-hole miniaturized aerodynamic pressure probe. In view of qualitative/quantitative validation purposes, numerical modelling based on steady RANS and Detached Eddy Simulation (DES) approach was performed for the lowest investigated BR of 2.0, which provided the best film coverage. Nevertheless the dilution of the coolant jets from the showerhead was predicted by DES, agreement with the measured cooling effectiveness in the leading edge region was still far from being achieved. Instead, the steady approach was enough to capture aerodynamic features such as vane load, wake loss and plenum to mainstream pressure ratio.


Author(s):  
Pingfan He ◽  
Dragos Licu ◽  
Martha Salcudean ◽  
Ian S. Gartshore

The effect of varying coolant density on film cooling effectiveness for a turbine blade-model was numerically investigated and compared with experimental data. This model had a semi-circular leading edge with four rows of laterally-inclined film cooling orifices positioned symmetrically about the stagnation line. A curvilinear coordinate-based CFD code was developed and used for the numerical investigation. The code used a domain segmentation strategy in conjunction with general curvilinear grids to model the complex blade configuration. A multigrid method was used to accelerate the convergence rate. The time-averaged, variable-density, Navier-Stokes equations together with the energy or scalar equation were solved. Turbulence closure was attained by the standard k–ε model with a near-wall k model. Either air or CO2 was used as coolant in three cases of injection through single rows and alternatively staggered double raws of holes. Two different blowing rates were investigated in each case and compared with experimental data. The experimental results were obtained using a wind tunnel model, and the mass/heat analogy was used to determine the film cooling effectiveness. The higher density of the carbon dioxide coolant (approximately 1.5 times the density of air) in the isothermal mass injection experiments, was used to simulate the effects of injection of a colder air in the corresponding adiabatic heat transfer situation. Good agreement between calculated and measured film cooling effectiveness was found for low blowing ratio M ≤ 0.5 and the effect of density was not significant. At higher blowing ratio M > 1 the calculations consistently overpredict the measured values of film cooling effectiveness.


Author(s):  
Zhonghao Tang ◽  
Gongnan Xie ◽  
Honglin Li ◽  
Wenjing Gao ◽  
Chunlong Tan ◽  
...  

Abstract Film cooling performance of the cylindrical film holes and the bifurcated film holes on the leading edge model of the turbine blade are investigated in this paper. The suitability of different turbulence models to predict local and average film cooling effectiveness is validated by comparing with available experimental results. Three rows of holes are arranged in a semi-cylindrical model to simulate the leading edge of the turbine blade. Four different film cooling structures (including a cylindrical film holes and other three different bifurcated film holes) and four different blowing ratios are studied in detail. The results show that the film jets lift off gradually in the leading edge area as the blowing ratio increases. And the trajectory of the film jets gradually deviate from the mainstream direction to the spanwise direction. The cylindrical film holes and vertical bifurcated film holes have better film cooling effectiveness at low blowing ratio while the other two transverse bifurcated film holes have better film cooling effectiveness at high blowing ratio. And the film cooling effectiveness of the transverse bifurcated film holes increase with the increasing the blowing ratio. Additionally, the advantage of transverse bifurcated holes in film cooling effectiveness is more obvious in the downstream region relative to the cylindrical holes. The Area-Average film cooling effectiveness of transverse bifurcated film holes is 38% higher than that of cylindrical holes when blowing ratio is 2.


2006 ◽  
Vol 128 (9) ◽  
pp. 879-888 ◽  
Author(s):  
Jaeyong Ahn ◽  
M. T. Schobeiri ◽  
Je-Chin Han ◽  
Hee-Koo Moon

Detailed film cooling effectiveness distributions are measured on the leading edge of a rotating gas turbine blade with two rows (pressure-side row and suction-side row from the stagnation line) of holes aligned to the radial axis using the pressure sensitive paint (PSP) technique. Film cooling effectiveness distributions are obtained by comparing the difference of the measured oxygen concentration distributions with air and nitrogen as film cooling gas respectively and by applying the mass transfer analogy. Measurements are conducted on the first-stage rotor blade of a three-stage axial turbine at 2400rpm (positive off-design), 2550rpm (design), and 3000rpm (negative off-design), respectively. The effect of three blowing ratios is also studied. The blade Reynolds number based on the axial chord length and the exit velocity is 200,000 and the total to exit pressure ratio was 1.12 for the first-stage rotor blade. The corresponding rotor blade inlet and outlet Mach numbers are 0.1 and 0.3, respectively. The film cooling effectiveness distributions are presented along with discussions on the influence of rotational speed (off design incidence angle), blowing ratio, and upstream nozzle wakes around the leading edge region. Results show that rotation has a significant impact on the leading edge film cooling distributions with the average film cooling effectiveness in the leading edge region decreasing with an increase in the rotational speed (negative incidence angle).


Author(s):  
K.-S. Kim ◽  
Youn J. Kim ◽  
S.-M. Kim

To enhance the film cooling performance in the vicinity of the turbine blade leading edge, the flow characteristics of the film-cooled turbine blade have been investigated using a cylindrical body model. The inclination of the cooling holes is along the radius of the cylindrical wall and 20 deg relative to the spanwise direction. Mainstream Reynolds number based on the cylinder diameter was 1.01×105 and 0.69×105, and the mainstream turbulence intensities were about 0.2% in both Reynolds numbers. CO2 was used as coolant to simulate the effect of density ratio of coolant-to-mainstream. Furthermore, the effect of coolant flow rates was studied for various blowing ratios of 0.4, 0.7, 1.1, and 1.4, respectively. In experiment, spatially-resolved temperature distributions along the cylindrical body surface were visualized using infrared thermography (IRT) in conjunction with thermocouples, digital image processing, and in situ calibration procedures. This comparison shows the results generated to be reasonable and physically meaningful. The film cooling effectiveness of current measurement (0.29 mm × 0.33 min per pixel) presents high spatial and temperature resolutions compared to other studies. Results show that the blowing ratio has a strong effect on film cooling effectiveness and the coolant trajectory is sensitive to the blowing ratio. The local spanwise-averaged effectiveness can be improved by locating the first-row holes near the second-row holes.


2014 ◽  
Vol 554 ◽  
pp. 317-321
Author(s):  
Mohamad Rasidi Bin Pairan ◽  
Norzelawati Binti Asmuin ◽  
Hamidon bin Salleh

Film cooling is one of the cooling techniques applied to the turbine blade. Gas turbine used film cooling technique to protect turbine blade from directly expose to the hot gas to avoid the blade from defect. The focus of this investigation is to investigate the effect of embedded three difference depth of trench at coolant holes geometry. Comparisons are made at four difference blowing ratios which are 1.0, 1.25 and 1.5. Three configuration leading edge with depth Case A (0.0125D), Case B (0.0350D) and Case C (0.713D) were compared to leading edge without trench. Result shows that as blowing ratio increased from 1.0 to 1.25, the film cooling effectiveness is increase for leading edge without trench and also for all cases. However when the blowing ratio is increase to 1.5, film cooling effectiveness is decrease for all cases. Overall the Case B with blowing ratio 1.25 has the best film cooling effectiveness with significant improvement compared to leading edge without trench and with trench Case A and Case C.


Author(s):  
G. Barigozzi ◽  
H. Abdeh ◽  
A. Perdichizzi ◽  
M. Henze ◽  
J. Krueckels

In the present paper, the influence of the presence of an inlet flow non uniformity on the aerodynamic and thermal performance of a film cooled linear nozzle vane cascade is fully assessed. Tests have been carried out with platform cooling, with coolant ejected through a slot located upstream of the leading edge. Cooling air is also ejected through a row of cylindrical holes located upstream of the slot, simulating a combustor cooling system. An obstruction was installed upstream of the cascade at variable tangential and axial position to generate a flow non uniformity. The cascade was tested at a high inlet turbulence intensity level (Tu1 = 9%) and at a constant inlet Mach number of 0.12 and nominal cooling condition. Aero-thermal characterization of vane platform was obtained through 5-hole probe and end wall adiabatic film cooling effectiveness measurements. Results show a relevant negative impact of inlet flow non uniformity on the cooled cascade aerodynamic and thermal performance. Higher film cooling effectiveness and lower aerodynamic losses are obtained when the inlet flow non uniformity is located at mid pitch, while lower effectiveness and higher losses are obtained when it is aligned to the vane leading edge. Moving the non uniformity axially or changing its blockage only marginally influences the platform thermal protection.


Author(s):  
Ian S. Gartshore ◽  
Marthe Salcudean ◽  
Y. Barnea ◽  
K. Zhang ◽  
F. Aghadsi

Experiments have been conducted on a large wind tunnel model of the leading edge region of a turbine blade. The model had a semi-circular leading edge in which four rows of holes were symmetrically placed about the stagnation line, two at ±15° and two at ±44°. Air and alternatively CO2 were injected from the coolant holes after contamination with a known small percentage of propane. Using a flame ionization detector and the mass transfer analogy, the film cooling effectiveness was measured at various overall mass flow ratios and at various streamwise locations for each coolant type. The division of coolant flow rate from the two rows of holes was found to be more unequal for CO2 than for air, an effect which is predicted from a simple analysis of the coolant/free stream interaction and the hole discharge coefficient. This has practical implications for actual turbine operation since earlier cut-off of the coolant from the front row of holes, due to density differences, could have disastrous effects on the blade. This effect also further complicates any attempt to identify overall trends of coolant density on performance. It is not possible to conclude that air or CO2 coolant has a higher film cooling effectiveness, although, in general, air appears better close to the first row of holes, and CO2 better at some distance downstream of both rows. Based on the measurements, the effects of mass flow ratio, momentum flux ratio, relative hole placement in each row, and spanwise versus streamwise injection are discussed in the paper.


Sign in / Sign up

Export Citation Format

Share Document