Estimation of Structural Reliability Under Random Fatigue Conditions

Author(s):  
J. D. Baldwin ◽  
J. G. Thacker ◽  
T. T. Baber

Abstract A procedure for determining the reliability of a structural element or machine part is presented. The solution assumes that the stress history in the part can be described by a narrow band, stationary, Gaussian random process and that the fatigue behavior of the part is governed by the classical S-N curve. Endurance limit modifications are discussed and a procedure is presented for determining the mean and standard deviation of the static stresses acting throughout a structure. A numerical example is presented showing the method applied to estimate the fatigue reliability of a power wheelchair frame.

Author(s):  
A. Ku ◽  
C. Serratella ◽  
R. Spong ◽  
R. Basu ◽  
G. Wang ◽  
...  

This paper outlines the essential steps taken in performing structural reliability calculations during the process of laying out a risk-based inspection program. The structural reliability analysis described in this paper essentially takes the deterministic finite element method (FEM) stress/fatigue analysis results, coupled with uncertain degradation mechanisms (e.g. corrosion rate, crack propagating parameters, etc.), and tracks the time-varying structural reliability index of the structural components under consideration. This can then be used to determine the timing for inspection of structural components. For the assessment of structural strength, an efficient and straightforward method is proposed to calculate the time-variant reliability index. This method is verified by an example problem and compared to the random process first-passage reliability solutions. Load combination issue is briefly discussed, in which an approach stems from the ABS Dynamic Loading Approach (DLA) coupled with concepts from Turkstra’s rule. This proposed simplistic load combination approach is verified through an example problem in which the result is compared to the solution calculated from a more sophisticated approach. Establishment of target reliability levels is also briefly discussed. For the assessment of fatigue behavior for welded connections, both S-N curve based and fracture mechanics based reliability methods are discussed. Their usefulness will be discussed in terms of both inspection interval as well as selecting the proper sampling percentage of connections to inspect. Statistical correlation among a group of similar connections is discussed to assist the selection of appropriate locations in the population of the aforementioned sampling. The usefulness of fatigue reliability analysis is also demonstrated by an example problem.


1966 ◽  
Vol 24 ◽  
pp. 170-180
Author(s):  
D. L. Crawford

Early in the 1950's Strömgren (1, 2, 3, 4, 5) introduced medium to narrow-band interference filter photometry at the McDonald Observatory. He used six interference filters to obtain two parameters of astrophysical interest. These parameters he calledlandc, for line and continuum hydrogen absorption. The first measured empirically the absorption line strength of Hβby means of a filter of half width 35Å centered on Hβand compared to the mean of two filters situated in the continuum near Hβ. The second index measured empirically the Balmer discontinuity by means of a filter situated below the Balmer discontinuity and two above it. He showed that these two indices could accurately predict the spectral type and luminosity of both B stars and A and F stars. He later derived (6) an indexmfrom the same filters. This index was a measure of the relative line blanketing near 4100Å compared to two filters above 4500Å. These three indices confirmed earlier work by many people, including Lindblad and Becker. References to this earlier work and to the systems discussed today can be found in Strömgren's article inBasic Astronomical Data(7).


1969 ◽  
Vol 14 (9) ◽  
pp. 470-471
Author(s):  
M. DAVID MERRILL
Keyword(s):  

1972 ◽  
Vol 28 (03) ◽  
pp. 447-456 ◽  
Author(s):  
E. A Murphy ◽  
M. E Francis ◽  
J. F Mustard

SummaryThe characteristics of experimental error in measurement of platelet radioactivity have been explored by blind replicate determinations on specimens taken on several days on each of three Walker hounds.Analysis suggests that it is not unreasonable to suppose that error for each sample is normally distributed ; and while there is evidence that the variance is heterogeneous, no systematic relationship has been discovered between the mean and the standard deviation of the determinations on individual samples. Thus, since it would be impracticable for investigators to do replicate determinations as a routine, no improvement over simple unweighted least squares estimation on untransformed data suggests itself.


2020 ◽  
Vol 92 (6) ◽  
pp. 51-58
Author(s):  
S.A. SOLOVYEV ◽  

The article describes a method for reliability (probability of non-failure) analysis of structural elements based on p-boxes. An algorithm for constructing two p-blocks is shown. First p-box is used in the absence of information about the probability distribution shape of a random variable. Second p-box is used for a certain probability distribution function but with inaccurate (interval) function parameters. The algorithm for reliability analysis is presented on a numerical example of the reliability analysis for a flexural wooden beam by wood strength criterion. The result of the reliability analysis is an interval of the non-failure probability boundaries. Recommendations are given for narrowing the reliability boundaries which can reduce epistemic uncertainty. On the basis of the proposed approach, particular methods for reliability analysis for any structural elements can be developed. Design equations are given for a comprehensive assessment of the structural element reliability as a system taking into account all the criteria of limit states.


2020 ◽  
Vol 1 (2) ◽  
pp. 56-66
Author(s):  
Irma Linda

Background: Early marriages are at high risk of marital failure, poor family quality, young pregnancies at risk of maternal death, and the risk of being mentally ill to foster marriage and be responsible parents. Objective: To determine the effect of reproductive health education on peer groups (peers) on the knowledge and perceptions of adolescents about marriage age maturity. Method: This research uses the Quasi experimental method with One group pre and post test design, conducted from May to September 2018. The statistical analysis used in this study is a paired T test with a confidence level of 95% (α = 0, 05). Results: There is an average difference in the mean value of adolescent knowledge between the first and second measurements is 0.50 with a standard deviation of 1.922. The mean difference in mean scores of adolescent perceptions between the first and second measurements was 4.42 with a standard deviation of 9.611. Conclusion: There is a significant difference between adolescent knowledge on the pretest and posttest measurements with a value of P = 0.002, and there is a significant difference between adolescent perceptions on the pretest and posttest measurements with a value of p = 0.001. Increasing the number of facilities and facilities related to reproductive health education by peer groups (peers) in adolescents is carried out on an ongoing basis at school, in collaboration with local health workers as prevention of risky pregnancy.


1988 ◽  
Vol 60 (1) ◽  
pp. 1-29 ◽  
Author(s):  
E. D. Young ◽  
J. M. Robert ◽  
W. P. Shofner

1. The responses of neurons in the ventral cochlear nucleus (VCN) of decerebrate cats are described with regard to their regularity of discharge and latency. Regularity is measured by estimating the mean and standard deviation of interspike intervals as a function of time during responses to short tone bursts (25 ms). This method extends the usual interspike-interval analysis based on interval histograms by allowing the study of temporal changes in regularity during transient responses. The coefficient of variation (CV), equal to the ratio of standard deviation to mean interspike interval, is used as a measure of irregularity. Latency is measured as the mean and standard deviation of the latency of the first spike in response to short tone bursts, with 1.6-ms rise times. 2. The regularity and latency properties of the usual PST histogram response types are shown. Five major PST response type classes are used: chopper, primary-like, onset, onset-C, and unusual. The presence of a prepotential in a unit's action potentials is also noted; a prepotential implies that the unit is recorded from a bushy cell. 3. Units with chopper PST histograms give the most regular discharge. Three varieties of choppers are found. Chop-S units (regular choppers) have CVs less than 0.35 that are approximately constant during the response; chop-S units show no adaptation of instantaneous rate, as measured by the inverse of the mean interspike interval. Chop-T units have CVs greater than 0.35, show an increase in irregularity during the response and show substantial rate adaptation. Chop-U units have CVs greater than 0.35, show a decrease in irregularity during the response, and show a variety of rate adaptation behaviors, including negative adaptation (an increase in rate during a short-tone response). Irregular choppers (chop-T and chop-U units) rarely have CVs greater than 0.5. Choppers have the longest latencies of VCN units; all three groups have mean latencies at least 1 ms longer than the shortest auditory nerve (AN) fiber mean latencies. 4. Chopper units are recorded from stellate cells in VCN (35, 42). Our results for chopper units suggest a model for stellate cells in which a regularly firing action potential generator is driven by the summation of the AN inputs to the cell, where the summation is low-pass filtered by the membrane capacitance of the cell.(ABSTRACT TRUNCATED AT 400 WORDS)


Cancers ◽  
2021 ◽  
Vol 13 (10) ◽  
pp. 2421
Author(s):  
Roberta Fusco ◽  
Vincenza Granata ◽  
Mauro Mattace Raso ◽  
Paolo Vallone ◽  
Alessandro Pasquale De Rosa ◽  
...  

Purpose. To combine blood oxygenation level dependent magnetic resonance imaging (BOLD-MRI), dynamic contrast enhanced MRI (DCE-MRI), and diffusion weighted MRI (DW-MRI) in differentiation of benign and malignant breast lesions. Methods. Thirty-seven breast lesions (11 benign and 21 malignant lesions) pathologically proven were included in this retrospective preliminary study. Pharmaco-kinetic parameters including Ktrans, kep, ve, and vp were extracted by DCE-MRI; BOLD parameters were estimated by basal signal S0 and the relaxation rate R2*; and diffusion and perfusion parameters were derived by DW-MRI (pseudo-diffusion coefficient (Dp), perfusion fraction (fp), and tissue diffusivity (Dt)). The correlation coefficient, Wilcoxon-Mann-Whitney U-test, and receiver operating characteristic (ROC) analysis were calculated and area under the ROC curve (AUC) was obtained. Moreover, pattern recognition approaches (linear discrimination analysis and decision tree) with balancing technique and leave one out cross validation approach were considered. Results. R2* and D had a significant negative correlation (−0.57). The mean value, standard deviation, Skewness and Kurtosis values of R2* did not show a statistical significance between benign and malignant lesions (p > 0.05) confirmed by the ‘poor’ diagnostic value of ROC analysis. For DW-MRI derived parameters, the univariate analysis, standard deviation of D, Skewness and Kurtosis values of D* had a significant result to discriminate benign and malignant lesions and the best result at the univariate analysis in the discrimination of benign and malignant lesions was obtained by the Skewness of D* with an AUC of 82.9% (p-value = 0.02). Significant results for the mean value of Ktrans, mean value, standard deviation value and Skewness of kep, mean value, Skewness and Kurtosis of ve were obtained and the best AUC among DCE-MRI extracted parameters was reached by the mean value of kep and was equal to 80.0%. The best diagnostic performance in the discrimination of benign and malignant lesions was obtained at the multivariate analysis considering the DCE-MRI parameters alone with an AUC = 0.91 when the balancing technique was considered. Conclusions. Our results suggest that the combined use of DCE-MRI, DW-MRI and/or BOLD-MRI does not provide a dramatic improvement compared to the use of DCE-MRI features alone, in the classification of breast lesions. However, an interesting result was the negative correlation between R2* and D.


2021 ◽  
Vol 9 (6) ◽  
pp. 585
Author(s):  
Minghao Wu ◽  
Leen De Vos ◽  
Carlos Emilio Arboleda Chavez ◽  
Vasiliki Stratigaki ◽  
Maximilian Streicher ◽  
...  

The present work introduces an analysis of the measurement and model effects that exist in monopile scour protection experiments with repeated small scale tests. The damage erosion is calculated using the three dimensional global damage number S3D and subarea damage number S3D,i. Results show that the standard deviation of the global damage number σ(S3D)=0.257 and is approximately 20% of the mean S3D, and the standard deviation of the subarea damage number σ(S3D,i)=0.42 which can be up to 33% of the mean S3D. The irreproducible maximum wave height, chaotic flow field and non-repeatable armour layer construction are regarded as the main reasons for the occurrence of strong model effects. The measurement effects are limited to σ(S3D)=0.039 and σ(S3D,i)=0.083, which are minor compared to the model effects.


Sign in / Sign up

Export Citation Format

Share Document