Wet Gas Performance of Differential Pressure Flowmeters

Author(s):  
Russell Evans ◽  
Stephen A. Ifft

Wet gas flow measurement is becoming vital to the natural gas production industry. New wells with marginal outputs cannot justify gas-liquid separation equipment and must transfer gas which contains some liquid volume. The flow measurement device on each well dictates the allocation earnings and must therefore provide gas flow measurement as accurately as possible. Several types of differential pressure based flowmeters are currently being used in wet gas flow measurement. DP based flowmeters share many performance characteristics in wet gas applications. However, studies have also found that there can be significant differences in the correlations between meter over reading and liquid content depending of the type of DP meter being tested. Emerson Process Management conducted a series of wet gas tests on a standard orifice plate, a V-Cone, a Venturi and two Rosemount conditioning orifice plates at the National Engineering Laboratory in Scotland (NEL). Previously, tests of conditioning orifice plates in wet gas were conducted at the Colorado Engineering Experiment Station, Inc. (CEESI). The work described in this paper is aimed at investigating the similarities and differences in the performance of these meter types in wet gas flows. Comparisons of these data to those from previous studies on the meter types tested are presented. Also, as a result of these studies, a general method for correcting the over-reading of DP-based, wet gas flowmeters using process measurements and the flow computing capabilities of modern multivariable DP transmitters was developed and is presented.

2021 ◽  
pp. 13-19
Author(s):  
Zhanat А. Dayev ◽  
Gulzhan E. Shopanova ◽  
Bakytgul А. Toksanbaeva

The article deals with one of the important tasks of modern flow measurement, which is related to the measurement of the flow rate and the amount of wet gas. This task becomes especially important when it becomes necessary to obtain information about the separate amount of the dry part of the gas that is contained in the form of a mixture in the wet gas stream. The paper presents the principle of operation and structure of the invariant system for measuring the flow rate of wet gas, which is based on the combined use of differential pressure flowmeters and Coriolis flowmeters. The operation of the invariant wet gas flow rate measurement system is based on the simultaneous application of the multichannel principle and the partial flow measurement method. Coriolis flowmeters and the differential pressure flowmeter are used as the main elements of the system. The proposed measurement system does not offer applications for gases with abundant drip humidity. The article provides information about the test results of the proposed invariant system. The estimation of the metrological characteristics of the invariant system when measuring the flow rate of wet gas is given. The obtained test results of the invariant wet gas flow rate measurement system are relevant for natural gas production, transportation, and storage facilities.


2021 ◽  
Author(s):  
Sakethraman Mahalingam ◽  
Gavin Munro ◽  
Muhammad Arsalan ◽  
Victor Gawski

Abstract When the gas flow rate of a well significantly changes, the flow rate can fall below that of the operating range of a traditional fixed size Venturi meter, necessitating the replacement of the original meter with one of a smaller size. However, with an adjustable cone meter, the internal reconfiguration feature allows it to automatically switch from high operating flow range to low operating flow range and there is no requirement to disassemble the meter from the flow line assembly. Adjustable cone meters were designed, developed and tested at the wet-gas flow loop at National Engineering Laboratory in East Kilbride, Scotland. After calibrating the meter with dry nitrogen gas, the meter was tested with increasing amounts of liquid being injected into the flowline, upstream of the meter. The liquid caused the differential pressure measurement on the meter to over-read. Based on the differential pressure measurements under varying flow conditions, algorithms were developed to measure the dry gas and liquid fraction. The data obtained from the tests such as differential pressure, pressure, temperature, liquid density were used to build an over-reading model of the meter and a liquid fraction estimation model based on pressure loss ratio derived from an additional differential pressure measurement. The model was used to not only to quantify the gas and liquid flow rates but also the estimated error in each measurement. The measurements show that the Adjustable Cone meter is able to provide low uncertainty in both dry and wet gas conditions and offers a turndown ratio of up to 54:1 in dry gas conditions. In addition, the automatic adjustment of the meter from high flow to low flow positions avoids the need for manual intervention that involves additional risk and cost.


1989 ◽  
Author(s):  
N. Nederveen ◽  
G.V. Washington ◽  
F.H. Batstra
Keyword(s):  
Gas Flow ◽  

2011 ◽  
Vol 383-390 ◽  
pp. 4922-4927
Author(s):  
Peng Xia Xu ◽  
Yan Feng Geng

Wet gas flow is a typical two-phase flow with low liquid fractions. As differential pressure signal contains rich information of flow parameters in two-phase flow metering, a new method is proposed for wet gas flow metering based on differential pressure (DP) and blind source separation (BSS) techniques. DP signals are from a couple of slotted orifices and the BSS method is based on time-frequency analysis. A good relationship between the liquid flow rate and the characteristic quantity of the separated signal is established, and a differential pressure correlation for slotted orifice is applied to calculate the gas flow rate. The calculation results are good with 90% relative errors less than ±10%. The results also show that BSS is an effective method to extract liquid flow rate from DP signals of wet gas flow, and to analysis different interactions among the total DP readings.


2012 ◽  
Vol 12 (1) ◽  
pp. 19-24 ◽  
Author(s):  
Lide Fang ◽  
Lili Pang ◽  
Xiaoting Li ◽  
Xiuming Xiang ◽  
Qinghua Lu

2021 ◽  
Author(s):  
Griffin Beck ◽  
Nathan Andrews ◽  
A. Grey Berry ◽  
Amy McCleney

Abstract In gas processing, boosting, and gathering applications, gas-liquid separator equipment (typically referred to as a scrubber) is placed upstream of each reciprocating compressor stage to remove water and hydrocarbon condensates. However, field experience indicates that liquids are often still present downstream of the separation equipment. When liquids are ingested into the reciprocating compressor, machinery failures, some of which are severe, can result. While it is generally understood that liquid carryover and condensation can occur, it is less clear how the multiphase fluid moves through equipment downstream of the scrubber. In this paper, mechanisms responsible for liquid formation and carryover into reciprocating compressors are explored. First, the effects of liquid ingestion on reciprocating compressors reported in the open literature are reviewed. Then, the role of heat and pressure loss along the gas flow path is investigated to determine whether liquid formation (i.e., condensation) is likely to occur for two identical compressors with different pulsation bottle configurations. For this investigation, conjugate heat transfer (CHT) models of the suction pulsation bottles are used to identify regions where liquid dropout is likely to occur. Results of these investigations are presented. Next, liquid carryover from the upstream scrubber is considered. Multiphase models are developed to determine how the multiphase fluid flows through the complex flow path within the pulsation bottle. Two liquid droplet size distributions are employed in these models. Descriptions of the modeling techniques, assumptions, and boundary conditions are provided.


Author(s):  
Levi André B. Vigdal ◽  
Lars E. Bakken

Adopting the innovative technology found in a compressor able to compress a mixture of natural gas and condensate has great potential for meeting future challenges in subsea oil and gas production. Benefits include reduced size, complexity and cost, enhanced well output, longer producing life and increased profits, which in turn offer opportunities for exploiting smaller oil and gas discoveries or extending the commercial life of existing fields. Introducing liquid into a centrifugal compressor creates several thermodynamic and fluid-mechanical challenges. The paper reviews some of the drive mechanisms involved in wet gas compression and views them in the context of the test results presented. An inlet guide vane (IGV) assembly has been installed in a test facility for wet gas compressors and the effect of wet gas on IGV performance documented. The impact of changes in IGV performance on impeller and diffuser has also been documented. The results have been discussed and correction methods compared.