Predictions of Enhanced Heat Transfer of an Internal Blade Tip-Wall With Hemispherical Dimples or Protrusions

Author(s):  
Gongnan Xie ◽  
Bengt Sunde´n ◽  
Quiwang Wang

The blade tip region encounters high thermal loads because of the hot gas leakage flows, and it must therefore be cooled to ensure a long durability and safe operation. A common way to cool a blade tip is to design serpentine passages with 180-deg turn under the blade tip-cap inside the turbine blade. Improved internal convective cooling is therefore required to increase the blade tip lifetime. Dimples and protrusions are well recognized as effective devices to augment heat transfer in various applications. In this paper, enhanced heat transfer of an internal blade tip-wall has been predicted numerically. The computational models consist of a two-pass channel with 180-deg turn and arrays of hemispherical dimples or protrusions internally mounted on the tip-wall. Inlet Reynolds numbers are in the range of 100,000 to 600,000. The computations are three dimensional, steady, incompressible and non-rotating. The overall performance of the two-pass channels is also evaluated. It is found that due to the combination of turning impingement and protrusion crossflow or dimple advection, the heat transfer coefficient of the augmented tip is a factor of 2.0 higher than that of a smooth tip. This augmentation is achieved at the cost of a penalty of pressure drop by around 5%. By comparing the present dimples or protrusions performance with others in previous works, it is found that the augmented-tips show the best performance, and the dimpled or protruded tips are superior to those pin-finned tips when the active area enhancement is excluded. It is suggested that dimples and protrusions can be used to enhance blade tip heat transfer and hence improve blade tip cooling.

2011 ◽  
Vol 133 (4) ◽  
Author(s):  
Gongnan Xie ◽  
Bengt Sundén ◽  
Qiuwang Wang

The blade tip region encounters high thermal loads because of the hot gas leakage flows, and it must therefore be cooled to ensure a long durability and safe operation. A common way to cool a blade tip is to design serpentine passages with 180 deg turns under the blade tip-cap inside the turbine blade. Improved internal convective cooling is therefore required to increase the blade tip lifetime. Dimples and protrusions are well recognized as effective devices to augment heat transfer in various applications. In this paper, enhanced heat transfer of an internal blade tip-wall has been predicted numerically. The computational models consist of a two-pass channel with a 180 deg turn and arrays of hemispherical dimples or protrusions internally mounted on the tip-wall. Inlet Reynolds numbers are in the range of 100,000–600,000. The computations are three dimensional, steady, incompressible, and nonrotating. The overall performance of the two-pass channels is also evaluated. It is found that due to the combination of turning impingement and protrusion crossflow or dimple advection, the heat transfer coefficient of the augmented tip is a factor of 2.0 higher than that of a smooth tip. This augmentation is achieved at the cost of a penalty of pressure drop by around 5%. By comparing the present dimples’ or protrusions’ performance with others in previous works, it is found that the augmented tips show the best performance, and the dimpled or protruded tips are superior to those pin-finned tips when the active area enhancement is excluded. It is suggested that dimples and protrusions can be used to enhance blade tip heat transfer and hence improve blade tip cooling.


Author(s):  
Gongnan Xie ◽  
Bengt Sunde´n ◽  
Weihong Zhang

The blade tip region encounters high thermal loads because of the hot gas leakage flows, and it must therefore be cooled to ensure a long durability and safe operation. A common way to cool a blade tip is to design serpentine passages with 180° turn under the blade tip-cap inside the turbine blade. Improved internal convective cooling is therefore required to increase blade tip lifetime. Pins, dimples and protrusions are well recognized as effective devices to augment heat transfer in various applications. In this paper, enhanced heat transfer of an internal blade tip-wall has been predicted numerically. The computational models consist of a two-pass channel with 180° turn and arrays of circular pins or hemispherical dimples or protrusions internally mounted on the tip-wall. Inlet Reynolds numbers are ranging from 100,000 to 600,000. The overall performance of the two-pass channels is evaluated. Numerical results show that the heat transfer enhancement of the pinned tip is up to a factor of 3.0 higher than that of a smooth tip while the dimpled-tip and protruded-tip provide about 2.0 times higher heat transfer. These augmentations are achieved at the cost of an increase of pressure drop by less than 10%. By comparing the present cooling concepts with pins, dimples and protrusions, it is shown that the pinned-tip exhibit best performance to improve the blade tip cooling. However, when disregarding the added active area and considering the added mechanical stress, it is suggested that the usage of dimples is more suitable to enhance blade tip cooling, especially at low Reynolds numbers.


2011 ◽  
Vol 133 (6) ◽  
Author(s):  
Gongnan Xie ◽  
Bengt Sundén ◽  
Weihong Zhang

The blade tip region encounters high thermal loads because of the hot gas leakage flows, and it must therefore be cooled to ensure a long durability and safe operation. A common way to cool a blade tip is to design serpentine passages with a 180 deg turns under the blade tip-cap inside the turbine blade. Improved internal convective cooling is therefore required to increase blade tip lifetime. Pins, dimples, and protrusions are well recognized as effective devices to augment heat transfer in various applications. In this paper, enhanced heat transfer of an internal blade tip-wall has been predicted numerically. The computational models consist of a two-pass channel with 180 deg turn and arrays of circular pins, hemispherical dimples, or protrusions internally mounted on the tip-wall. Inlet Reynolds numbers are ranging from 100,000 to 600,000. The overall performance of the two-pass channels is evaluated. Numerical results show that the heat transfer enhancement of the pinned-tip is up to a factor of 3.0 higher than that of a smooth tip while the dimpled-tip and protruded-tip provide about 2.0 times higher heat transfer. These augmentations are achieved at the cost of an increase of pressure drop by less than 10%. By comparing the present cooling concepts with pins, dimples, and protrusions, it is shown that the pinned-tip exhibits best performance to improve the blade tip cooling. However, when disregarding the added active area and considering the added mechanical stress, it is suggested that the usage of dimples is more suitable to enhance blade tip cooling, especially at low Reynolds numbers.


2011 ◽  
Vol 3 (3) ◽  
pp. 297-309 ◽  
Author(s):  
Gongnan Xie ◽  
Bengt Sundén

AbstractCooling methods are needed for turbine blade tips to ensure a long durability and safe operation. A common way to cool a tip is to use serpentine passages with 180-deg turn under the blade tip-cap taking advantage of the three-dimensional turning effect and impingement like flow. Improved internal convective cooling is therefore required to increase the blade tip lifetime. In the present study, augmented heat transfer of an internal blade tip with pin-fin arrays has been investigated numerically using a conjugate heat transfer method. The computational domain includes the fluid region and the solid pins as well as the tip regions. Turbulent convective heat transfer between the fluid and pins, and heat conduction within pins and tip are simultaneously computed. The main objective of the present study is to observe the effect of the pin material on heat transfer enhancement of the pin-finned tips. It is found that due to the combination of turning, impingement and pin-fin crossflow, the heat transfer coefficient of a pin-finned tip is a factor of 2.9 higher than that of a smooth tip at the cost of an increased pressure drop by less than 10%. The usage of metal pins can reduce the tip temperature effectively and thereby remove the heat load from the tip. Also, it is found that the tip heat transfer is enhanced even by using insulating pins having low thermal conductivity at low Reynolds numbers. The comparisons of overall performances are also included.


Author(s):  
G. N. Xie ◽  
B. Sunde´n ◽  
L. Wang ◽  
E. Utriainen

The heat transferred to the turbine blade is substantially increased as the turbine inlet temperature is increased. Cooling methods are therefore much needed for the turbine blades to ensure a long durability and safe operation. The blade tip region is exposed to the hot gas flows. A common way to cool the tip is to use serpentine passages with 180-deg turn under the blade tip cap taking advantage of the three-dimensional turning effect and impingement. Improving internal convective cooling is therefore required to increase the blade tip life. In this paper, augmented heat transfer of a blade tip has been investigated numerically. The computational models consist of a two-pass channel with 180-deg turn and an array of pin-fins mounted on the tip-cap, and a smooth two-pass channel. Inlet Reynolds numbers are ranging from 100,000 to 600,000. The computations are 3D, steady, incompressible and stationary. The detailed 3D fluid flow and heat transfer over the tip surfaces are presented. The overall performance of the two models is evaluated. It is found that the pin-fins make the counter-rotating vortices towards pin-fin surfaces, resulting in continuous turbulent mixing near the pin-finned tip. Due to the combination of turning, impingement and pin-fin crossflow, the heat transfer coefficient of the pin-finned tip is a factor of as much as 1.84 higher than that of a smooth tip. This augmentation is achieved at the expense of a penalty of pressure drop around 35%. It is suggested that the pin-fins could be used to enhance blade tip heat transfer and cooling.


Author(s):  
G. N. Xie ◽  
B. Sunde´n ◽  
L. K. Wang ◽  
E. Utriainen

A common way to cool the tip is to use serpentine passages with 180-deg turn under the blade tip-cap. Improving internal convective cooling is therefore required to increase the blade tip life. In this paper, augmented heat transfer of a blade tip has been investigated numerically. The computational models consist of a two-pass channel with 180-deg turn and pin-fins mounted on the tip-cap, and a smooth two-pass channel. On the other hand, In particular manufacture, the casting process does not make a perfect cylinder pin, a fillet needs to be placed at the endwall. In order to make the conditions of simulations as close to real practice as possible, it is desirable to examine the effect of fillet on the tip heat transfer. Therefore, in the present study, the effect of pin base-fillet on heat transfer enhancement of a blade pin-finned tip-wall is investigated numerically. Inlet Reynolds numbers are ranging from 100,000 to 600,000. The computations are 3D, steady, incompressible and stationary. It is found that the pin-fins make the counter-rotating vortices towards pin-fin surfaces, resulting in continuous turbulent mixing near the pin-finned tip. Due to the combination of turning, impingement and pin-fin crossflow, the heat transfer coefficient of the pin-finned tip is a factor of as much as 2.66 higher than that of a smooth tip. Besides, with base-fillets the heat transfer enhancement is increased by about 10% while almost no additional pressure loss is resulted. It is suggested that the pin-fins could be used to enhance blade tip heat transfer and cooling.


Author(s):  
Vijay K. Garg ◽  
Ali A. Ameri

A three-dimensional Navier-Stokes code has been used to compute the heat transfer coefficient on two film-cooled turbine blades, namely the VKI rotor with six rows of cooling holes including three rows on the shower head, and the C3X vane with nine rows of holes including five rows on the shower head. Predictions of heat transfer coefficient at the blade surface using three two-equation turbulence models, specifically, Coakley’s q-ω model, Chien’s k-ε model and Wilcox’s k-ω model with Menter’s modifications, have been compared with the experimental data of Camci and Arts (1990) for the VKI rotor, and of Hylton et al. (1988) for the C3X vane along with predictions using the Baldwin-Lomax (B-L) model taken from Garg and Gaugler (1995). It is found that for the cases considered here the two-equation models predict the blade heat transfer somewhat better than the B-L model except immediately downstream of the film-cooling holes on the suction surface of the VKI rotor, and over most of the suction surface of the C3X vane. However, all two-equation models require 40% more computer core than the B-L model for solution, and while the q-ω and k-ε models need 40% more computer time than the B-L model, the k-ω model requires at least 65% more time due to slower rate of convergence. It is found that the heat transfer coefficient exhibits a strong spanwise as well as streamwise variation for both blades and all turbulence models.


Author(s):  
Gm S. Azad ◽  
Je-Chin Han ◽  
Robert J. Boyle

Experimental investigations are performed to measure the detailed heat transfer coefficient and static pressure distributions on the squealer tip of a gas turbine blade in a five-bladed stationary linear cascade. The blade is a 2-dimensional model of a modern first stage gas turbine rotor blade with a blade tip profile of a GE-E3 aircraft gas turbine engine rotor blade. A squealer (recessed) tip with a 3.77% recess is considered here. The data on the squealer tip are also compared with a flat tip case. All measurements are made at three different tip gap clearances of about 1%, 1.5%, and 2.5% of the blade span. Two different turbulence intensities of 6.1% and 9.7% at the cascade inlet are also considered for heat transfer measurements. Static pressure measurements are made in the mid-span and near-tip regions, as well as on the shroud surface opposite to the blade tip surface. The flow condition in the test cascade corresponds to an overall pressure ratio of 1.32 and an exit Reynolds number based on the axial chord of 1.1×106. A transient liquid crystal technique is used to measure the heat transfer coefficients. Results show that the heat transfer coefficient on the cavity surface and rim increases with an increase in tip clearance. The heat transfer coefficient on the rim is higher than the cavity surface. The cavity surface has a higher heat transfer coefficient near the leading edge region than the trailing edge region. The heat transfer coefficient on the pressure side rim and trailing edge region is higher at a higher turbulence intensity level of 9.7% over 6.1% case. However, no significant difference in local heat transfer coefficient is observed inside the cavity and the suction side rim for the two turbulence intensities. The squealer tip blade provides a lower overall heat transfer coefficient when compared to the flat tip blade.


Author(s):  
Puxuan Li ◽  
Steve J. Eckels

Accurate measurements of heat transfer and pressure drop play important roles in thermal designs in a variety of pipes and ducts. In this study, the convective heat transfer coefficient was measured with a semi-local surface average based on Newton’s Law of cooling. Flow and heat transfer data for different Reynolds numbers were collected and compared in a duct with smooth walls. Pressure drop was measured with a pressure transducer from OMEGA Engineering Inc. The experimental results were compared with numerical estimations generated in ANSYS Fluent. Fluent contains the broad physical modeling capabilities needed to model heat transfer and pressure drop in the duct. Thermal conduction and convection in the three-dimensional (3D) duct are simulated together. Special cares for selecting the viscosity models and the near-wall treatments are discussed. The goal of the paper is to find appropriate numerical models for simulating heat conduction, heat convection and pressure drop in the duct with different Reynolds numbers. The relationship between the heat transfer coefficient and Reynolds numbers is discussed. Heat flux and inlet temperature measured in the experiment are applied to the boundary conditions. The study provides the unique opportunity to verify the accuracy of numerical models on heat transfer and pressure drop in ANSYS Fluent.


Author(s):  
Abdulrahman Alenezi ◽  
Abdulrahman Almutairi ◽  
Hamad Alhajeri ◽  
Abdulaziz Gamil ◽  
Faisal Alshammari

Abstract A detailed heat transfer numerical study of a three-dimensional impinging jet on a roughened isothermal surface is presented and is investigated from flow physics vantage point under the influence of different parameters. The effects of the Reynolds number, roughness location, and roughness dimension on the flow physics and heat transfer parameters are studied. Additionally, the relations between average heat transfer coefficient (AHTC) and flow physics including pressure, wall shear and flow vortices with thermodynamic nonequilibrium are offered. This paper studies the effect of varying both location and dimension of the roughness element which took the shape of square cross-sectional continuous ribs to deliver a favorable trade-off between total pressure loss and heat transfer rate. The roughness element was tested for three different radial locations (R/D) = 1, 1.5, and 2 and at each location its height (i.e., width) (e) was changed from 0.25 to 1 mm in incremental steps of 0.25. The study used a jet angle (α) of 90 deg, jet-to-target distance (H/D = 6), and Re ranges from 10,000 to 50,000, where H is the vertical distance between the target plate and jet exit. The results show that the AHTC can be significantly affected by changing the geometry and dimensions of the roughness element. This variation can be either an augmentation of, or decrease in, the (HTC) when compared with the baseline case. An enhancement of 12.9% in the AHTC was achieved by using optimal location and dimensions of the roughness element at specific Reynolds number. However, a diminution between 10% and 30% in (AHTC) was attained by the use of rib height e = 1 mm at Re = 50k. The variation of both rib location and height showed better contribution in increasing heat transfer for low-range Reynolds numbers.


Sign in / Sign up

Export Citation Format

Share Document