Stall Margin Improvement by Use of Casing Treatments

Author(s):  
Christian T. Pixberg ◽  
Heinz-Peter Schiffer ◽  
M. H. Ross ◽  
J. D. Cameron ◽  
S. C. Morris

The beneficial impact of casing treatments on the stall margin of tip-critical compressors has been proven many times. However, there is still no simple and general method to predict their actual effectiveness. The present work considers the axial velocity deficit that is generally observed at the blade tip. This so called tip-blockage is caused by the tip clearance flow. That is investigated for different configurations of the transonic compressor test facilities in Darmstadt and Notre Dame and the results are presented in this paper. Similar circumferential groove casing treatments were applied to different single-stage and 1.5-stage compressors. They all had a tip critical behavior in common, but exhibited different design philosophies. The effectiveness of similar casing treatments on different stages was observed. A new method for calculating tip-blockage is introduced based on compressor performance and the results of a through-flow tool. A direct link between blockage growth and stall margin improvement was found for circumferential grooves casing treatments. Additionally, the results of an axial slot casing treatment are taken into account.

Author(s):  
N. A. Cumpsty

Results are presented and discussed from an axial compressor rotor operated with an axial skewed slot casing treatment over part of the circumference. The compressor was one for which stall was initiated in the tip region and for this type there is some potential for stall margin improvement with lower loss using this. The main significance of the experiments is, however, the possibility of looking at aspects of stall inception. Normally stall inception is a brief transient with an unknown start time and is difficult to study but with the partial casing treatment it was possible to make the untreated section operate continuously in such a way that it underwent the processes normally leading to stall. For a tip stalling rotor the experiments identify the annulus boundary layer as the crucial region of the flow and spillage of the tip-clearance flow forward of the blades as a process leading to the rapid build up of blockage prior to instability and stall.


Author(s):  
S. Saddoughi ◽  
G. Bennett ◽  
M. Boespflug ◽  
S. L. Puterbaugh ◽  
A. R. Wadia

Blade tip losses represent a major performance penalty in low aspect ratio transonic compressors. This paper reports on the experimental evaluation of the impact of tip clearance with and without plasma actuator flow control on performance of an U.S. Air Force-designed low aspect ratio, high radius ratio single-stage transonic compressor rig. The detailed stage performance measurements without flow control at three clearance levels, classified as small, medium and large, are presented. At design-speed, increasing the clearance from small to medium resulted in a stage peak efficiency drop of almost 6 points with another 4 point drop in efficiency with the large clearance. Comparison of the speed lines at high-speed show significantly lower pressure rise with increasing tip clearance, the compressor losing 8 percent stall margin with medium clearance and an additional 1 percent with the large clearance. Comparison of the stage exit radial profiles of total pressure and adiabatic efficiency at both part-speed and design-speed and with throttling are presented. Tip clearance flow-control was investigated using Dielectric Barrier Discharge (DBD) type plasma actuators. The plasma actuators were placed on the casing wall upstream of the rotor leading edge and the compressor mapped from part-speed to high-speed at three clearances with both axial and skewed configurations at six different frequency levels. The plasma actuators did not impact steady state performance. A maximum stall margin improvement of 4 percent was recorded in this test series. The large clearance configuration benefited the most with the plasma actuators. Increased voltage provided more stall margin improvement. Plasma actuator power requirements were almost halved going from continuous operation to pulsed plasma. Most of the improvement with the plasma actuators is attributed to the reduction in unsteadiness of the tip clearance vortex near-stall resulting in additional reduction in flow prior to stall.


Author(s):  
Daniel Möller ◽  
Maximilian Jüngst ◽  
Felix Holzinger ◽  
Christoph Brandstetter ◽  
Heinz-Peter Schiffer ◽  
...  

A flutter phenomenon was observed in a 1.5-stage configuration at the Darmstadt transonic compressor. This phenomenon is investigated numerically for different compressor speeds. The flutter occurs for the second eigenmode of the rotor blades and is caused by tip clearance flow which is able to pass through multiple rotor gaps at highly throttled operating points. The vibration pattern during flutter is accompanied by a pressure fluctuation pattern of the tip clearance flow which is interacting with the blade motion causing the aeroelastic instability. The velocity of the tip clearance flow fluctuation is about 50% of the blade tip speed for simulation and experiment and also matches the mean convective velocity inside the rotor gap. This is consistent for all compressor speeds. From this investigations, general guidelines are drawn which can be applied at an early stage during compressor design to evaluate the susceptibility to this kind of blade vibration.


2008 ◽  
Vol 131 (1) ◽  
Author(s):  
Xingen Lu ◽  
Wuli Chu ◽  
Junqiang Zhu ◽  
Yangfeng Zhang

In order to advance the understanding of the fundamental mechanisms of axial skewed slot casing treatment and their effects on the subsonic axial-flow compressor flow field, the coupled unsteady flow through a subsonic compressor rotor and the axial skewed slot was simulated with a state-of-the-art multiblock flow solver. The computational results were first compared with available measured data, that showed the numerical procedure calculates the overall effect of the axial skewed slot correctly. Then, the numerically obtained flow fields were interrogated to identify the physical mechanism responsible for improvement in stall margin of a modern subsonic axial-flow compressor rotor due to the discrete skewed slots. It was found that the axial skewed slot casing treatment can increase the stall margin of subsonic compressor by repositioning of the tip clearance flow trajectory further toward the trailing of the blade passage and retarding the movement of the incoming∕tip clearance flow interface toward the rotor leading edge plane.


Author(s):  
HaoGuang Zhang ◽  
Feng Tan ◽  
YanHui Wu ◽  
WuLi Chu ◽  
Wei Wang ◽  
...  

For compressor blade tip stall, one effective way of extending stable operating range is with the application of circumferential grooved casing treatment and its validity was proved by a lot of experimental and numerical investigations. The emphases of most circumferential grooved investigations are focused on the influence of groove depth and groove number on compressor stability, and there is few investigations dealt with the center offset degree of circumferential grooves casing treatment. Hence, an axial compressor rotor with casing treatment (CT) was investigated with experimental and numerical methods to explore the effect of center offset degree on compressor stability and performance. In the work reported here, The center offset degree is defined as the ratio of the central difference between rotor tip axial chord and CT to the axial chord length of rotor tip. When the center of CT is located within the upstream direction of the center of rotor tip axial chord, the value of center offset degree is positive. The experimental and numerical results show that stall margin improvement gained with CT is reduced as the value of center offset degree varies from 0 to 0.33 or −0.33, and the CT with −0.33 center offset degree achieves the lowest value of stall margin improvement at 53% and 73% design rotational speed. The detailed analysis of the flow-field in compressor tip indicates that there is not positive effect made by grooves on leading edge of rotor blade tip when the value of center offset degree is −0.33. As the mass flow of compressor reduces further, tip clearance leakage flow results in the outlet blockage due to the absence of the positive action of grooves near blade tip tail when the value of center offset degree is 0.33. Blockage does not appear in rotor tip passage owing to utilizing the function of all grooves with CT of 0 center offset degree.


Author(s):  
M. Voges ◽  
R. Schnell ◽  
C. Willert ◽  
R. Mo¨nig ◽  
M. W. Mu¨ller ◽  
...  

A single-stage transonic axial compressor was equipped with a casing treatment (CT), consisting of 3.5 axial slots per rotor pitch in order to investigate the predicted extension of the stall margin characteristics both numerically and experimentally. Contrary to most other studies the CT was designed especially accounting for an optimized optical access in the immediate vicinity of the CT, rather than giving maximum benefit in terms of stall margin extension. Part 1 of this two-part contribution describes the experimental investigation of the blade tip interaction with casing treatment using Particle image velocimetry (PIV). The nearly rectangular geometry of the CT cavities allowed a portion of it to be made of quartz glass with curvatures matching the casing. Thus the flow phenomena could be observed with essentially no disturbance caused by the optical access. Two periscope light sheet probes were specifically designed for this application to allow for precise alignment of the laser light sheet at three different radial positions in the rotor passage (87.5%, 95% and 99%). For the outermost radial position the light sheet probe was placed behind the rotor and aligned to pass the light sheet through the blade tip clearance. It was demonstrated that the PIV technique is capable of providing velocity information of high quality even in the tip clearance region of the rotor blades. The chosen type of smoke-based seeding with very small particles (about 0.5 μm in diameter) supported data evaluation with high spatial resolution, resulting in a final grid size of 0.5 × 0.5 mm. The PIV data base established in this project forms the basis for further detailed evaluations of the flow phenomena present in the transonic compressor stage with CT and allows validation of accompanying CFD calculations using the TRACE code. Based on the combined results of PIV measurements and CFD calculations of the same compressor and CT geometry a better understanding of the complex flow characteristics can be achieved, as detailed in Part 2 of this paper.


Author(s):  
Dakun Sun ◽  
Xiaofeng Sun ◽  
Xiaohua Liu ◽  
Feng Lin ◽  
Nie Chao Qun

A kind of novel casing treatment is proposed to realize stall margin enhancement by suppressing stall precursor in turbomachinery. In view of its different configuration and mechanism, such casing treatment is named as stall precursor-suppressed casing treatment in the present work, or SPS casing treatment for short. In the present work, the experiments of SPS casing treatment are conducted in a transonic compressor J69 Rotor/Stage. The SPS casing treatment which consists of a backchamber and a perforated plate is designed according to a proposed theoretical model. It is noted that the open area ratio of the casing treatment is only 4–12%, which is much smaller than traditional casing treatments with over 50% open area ratio. The tests show that the SPS casing treatment can improve the stall margin by 8–12% for J69 Rotor, and 4–12% for J69 Stage. Meanwhile, the mechanism of stall margin improvement with such casing treatment will be revealed in this investigation. Comparing with the evolution of the precursors without casing treatments, the propagation of the stall inception waves will be suppressed and the non-linear development of the stall process will be delayed under the casing treatment case.


Author(s):  
Shengfeng Zhao ◽  
Xingen Lu ◽  
Junqiang Zhu ◽  
Hongwu Zhang

The use of slots and grooves in the shroud over the tips of compressor blades, known as casing treatment, is a powerful method to control tip leakage flow through the clearance gap and enhance the flow stability in compressors. This paper presents a contribution to the understanding of the physical mechanism by which circumferential groove casing treatment manipulates the tip clearance flow’s unsteadiness. A series of computational studies were carried out to understand the physical mechanism responsible for improvement in stall margin of a high subsonic axial-flow compressor rotor due to the circumferential groove casing treatment from an unsteady viewpoint. Detailed analyses of the flow visualization at the tip have exposed the different tip flow topologies between the cases with circumferential groove and with untreated smooth wall. It was found that the primary stall margin enhancement afforded by the circumferential groove casing treatment is a result of the unsteady tip clearance flow manipulation. Breaking balance of incoming/tip clearance flow axial momentum by inducing the radial movement and tangential movement and delay the occurrence of tip clearance’s unsteadiness are the physical mechanisms responsible for extending the compressor stall margin.


2010 ◽  
Vol 133 (1) ◽  
Author(s):  
M. Voges ◽  
R. Schnell ◽  
C. Willert ◽  
R. Mönig ◽  
M. W. Müller ◽  
...  

A single-stage transonic axial compressor was equipped with a casing treatment (CT), consisting of 3.5 axial slots per rotor pitch in order to investigate the predicted extension of the stall margin characteristics both numerically and experimentally. Contrary to most other studies, the CT was designed especially accounting for an optimized optical access in the immediate vicinity of the CT, rather than giving maximum benefit in terms of stall margin extension. Part I of this two-part contribution describes the experimental investigation of the blade tip interaction with casing treatment using particle image velocimetry (PIV). The nearly rectangular geometry of the CT cavities allowed a portion of it to be made of quartz glass with curvatures matching the casing. Thus, the flow phenomena could be observed with essentially no disturbance caused by the optical access. Two periscope light sheet probes were specifically designed for this application to allow for precise alignment of the laser light sheet at three different radial positions in the rotor passage (87.5%, 95%, and 99%). For the outermost radial position, the light sheet probe was placed behind the rotor and aligned to pass the light sheet through the blade tip clearance. It was demonstrated that the PIV technique is capable of providing velocity information of high quality even in the tip clearance region of the rotor blades. The chosen type of smoke-based seeding with very small particles (about 0.5 μm in diameter) supported data evaluation with high spatial resolution, resulting in a final grid size of 0.5×0.5 mm2. The PIV database established in this project forms the basis for further detailed evaluations of the flow phenomena present in the transonic compressor stage with CT and allows validation of accompanying computational fluid dynamics (CFD) calculations using the TRACE code. Based on the combined results of PIV measurements and CFD calculations of the same compressor and CT geometry, a better understanding of the complex flow characteristics can be achieved, as detailed in Part II of this paper.


Author(s):  
Xingen Lu ◽  
Wuli Chu ◽  
Junqiang Zhu ◽  
Yanhui Wu

The use of slots and grooves in the shroud over the tips of compressor blades, known as casing treatment, is known as a powerful method to control tip leakage flow through the clearance gap and enhance the flow stability in compressors. This paper present a detailed steady and unsteady numerical studies of the coupled flow through rotor blade passages and two different types of casing treatment for a modern subsonic axial-flow compressor rotor. Particular attention was given to examining the interaction between the tip leakage flow and the casing treatment. In order to validate the multi block model applied in the rotor blade end-wall region, the computational results for the modern subsonic compressor rotor both with and without casing treatment were correlated with available experimental test data for estimation of the global performance. Detailed analyses of the flow visualization at the tip have exposed the different tip flow topologies between the cases with casing treatment and with untreated smooth wall. It was found that the primary stall margin enhancement afforded by the casing treatment is a result of the tip clearance flow manipulation. The repositioning of the tip clearance vortex further towards the trailing edge of the blade passage and delaying the movement of incoming/tip clearance flow interface to the leading edge plane are the physical mechanisms responsible for extending the compressor stall margin.


Sign in / Sign up

Export Citation Format

Share Document