Simulation of Wake Interactions in Wind Farms Using an Immersed Wind Turbine Model

Author(s):  
S. Jafari ◽  
N. Chokani ◽  
R. S. Abhari

The accurate modelling of the wind turbine wakes in complex terrain is required to accurately predict wake losses. In order to facilitate the routine use of computational fluid dynamics in the optimised micrositing of wind turbines within wind farms, an immersed wind turbine model is developed. This model is formulated to require grid resolutions that are comparable to that in microscale wind simulations. The model in connection with the k-ω turbulence model is embedded in a Reynolds-Averaged Navier Stokes solver. The predictions of the model are compared to available wind tunnel experiments and to measurements at the full-scale Sexbierum wind farm. The good agreement between the predictions and measurements demonstrates that the novel immersed turbine model is suited for the optimised micrositing of wind turbines in complex terrain.

2013 ◽  
Vol 136 (6) ◽  
Author(s):  
S. Jafari ◽  
N. Chokani ◽  
R. S. Abhari

The accurate modeling of the wind turbine wakes in complex terrain is required to accurately predict wake losses. In order to facilitate the routine use of computational fluid dynamics in the optimized micrositing of wind turbines within wind farms, an immersed wind turbine model is developed. This model is formulated to require grid resolutions that are comparable to that in microscale wind simulations. The model in connection with the k-ω turbulence model is embedded in a Reynolds-averaged Navier–Stokes solver. The predictions of the model are compared to available wind tunnel experiments and to measurements at the full-scale Sexbierum wind farm. The good agreement between the predictions and measurements demonstrates that the novel immersed turbine model is suited for the optimized micrositing of wind turbines in complex terrain.


Energies ◽  
2020 ◽  
Vol 13 (4) ◽  
pp. 882 ◽  
Author(s):  
Hongyan Ding ◽  
Zuntao Feng ◽  
Puyang Zhang ◽  
Conghuan Le ◽  
Yaohua Guo

The composite bucket foundation (CBF) for offshore wind turbines is the basis for a one-step integrated transportation and installation technique, which can be adapted to the construction and development needs of offshore wind farms due to its special structural form. To transport and install bucket foundations together with the upper portion of offshore wind turbines, a non-self-propelled integrated transportation and installation vessel was designed. In this paper, as the first stage of applying the proposed one-step integrated construction technique, the floating behavior during the transportation of CBF with a wind turbine tower for the Xiangshui wind farm in the Jiangsu province was monitored. The influences of speed, wave height, and wind on the floating behavior of the structure were studied. The results show that the roll and pitch angles remain close to level during the process of lifting and towing the wind turbine structure. In addition, the safety of the aircushion structure of the CBF was verified by analyzing the measurement results for the interaction force and the depth of the liquid within the bucket. The results of the three-DOF (degree of freedom) acceleration monitoring on the top of the test tower indicate that the wind turbine could meet the specified acceleration value limits during towing.


Author(s):  
Paul Sclavounos ◽  
Christopher Tracy ◽  
Sungho Lee

Wind is the fastest growing renewable energy source, increasing at an annual rate of 25% with a worldwide installed capacity of 74 GW in 2007. The vast majority of wind power is generated from onshore wind farms. Their growth is however limited by the lack of inexpensive land near major population centers and the visual pollution caused by large wind turbines. Wind energy generated from offshore wind farms is the next frontier. Large sea areas with stronger and steadier winds are available for wind farm development and 5MW wind turbine towers located 20 miles from the coastline are invisible. Current offshore wind turbines are supported by monopoles driven into the seafloor at coastal sites a few miles from shore and in water depths of 10–15m. The primary impediment to their growth is visual pollution and the prohibitive cost of seafloor mounted monopoles in larger water depths. This paper presents a fully coupled dynamic analysis of floating wind turbines that enables a parametric design study of floating wind turbine concepts and mooring systems. Pareto optimal designs are presented that possess a favorable combination of nacelle acceleration, mooring system tension and displacement of the floating structure supporting a five megawatt wind turbine. All concepts are selected so that they float stably while in tow to the offshore wind farm site and prior to their connection to the mooring system. A fully coupled dynamic analysis is carried out of the wind turbine, floater and mooring system in wind and a sea state based on standard computer programs used by the offshore and wind industries. The results of the parametric study are designs that show Pareto fronts for mean square acceleration of the turbine versus key cost drivers for the offshore structure that include the weight of the floating structure and the static plus dynamic mooring line tension. Pareto optimal structures are generally either a narrow deep drafted spar, or a shallow drafted barge ballasted with concrete. The mooring systems include both tension leg and catenary mooring systems. In some of the designs, the RMS acceleration of the wind turbine nacelle can be as low as 0.03 g in a sea state with a significant wave height of ten meters and water depths of up to 200 meters. These structures meet design requirements while possessing a favorable combination of nacelle accleration, total mooring system tension and weight of the floating structure. Their economic assessment is also discussed drawing upon a recent financial analysis of a proposed offshore wind farm.


Author(s):  
Hideyuki Suzuki ◽  
Yu Kitahara ◽  
Yukinari Fukumoto

A wide range of platform concepts have been investigated for a floating wind turbine. So far analysis and design of motion characteristics of the platform is main research concern. One key research area less focused is floating platform related risk. If the wind energy would be one of the major sources of electric power supply, wind farms which are comprised of large number of floating wind turbines must be deployed in the ocean. Wind turbines are relatively closely arranged in a wind farm. In such an arrangement, a wind turbine accidentally started drifting will have some possibility to collide with floater and moorings of neighboring moored floating wind turbines, and might initiate another drift which might cause progressive drifting of wind turbines. In the previous report, a scenario of progressive drifting of wind turbines was investigated and associated risk was formulated. Quantitative risk of several arrangements of wind farm was estimated. Effects of arrangement of wind turbines in a wind farm and safety factor used in the design of moorings is discussed. Probability of initial drift was evaluated analyzing past records of accidents and design of mooring. In this research, strength of mooring system was modeled more precisely and probabilistic model was developed considering aged deterioration. Risk of progressive drifting was evaluated and safety factor required to realize a acceptable risk of a wind farm was discussed.


Author(s):  
Hideyuki Suzuki ◽  
Masaru Kurimoto ◽  
Yu Kitahara ◽  
Yukinari Fukumoto

A wide range of platform types have been investigated for a floating wind turbine. Most of the research projects on a floating wind turbine assume that a land based wind turbine is to be installed on a platform with minimum modification to reduce the overall cost. For this reason, allowable limit of a motion of wind turbine is limited to lower value, for example, five degrees for static inclination and one to two degrees for pitching motion. So far analysis and design of motion characteristics of the platform have been main research concern. One key research area less focused is floating platform related risk. If the wind energy would be one of the major sources of power supply, wind farms which are comprised of large number of floating wind turbines must be deployed in the ocean. Wind turbines will be closely spaced in a wind farm so that installation cost should be minimized. In such an arrangement, a wind turbine accidentally started drifting has some possibility to collide or contact with the moorings of neighboring wind turbines and might cause progressive drifting of wind turbines. This paper present investigation of scenario of progressive drifting of floating wind turbines and evaluate risk of the scenario. Quantitative risk of several arrangements of wind farms is estimated. Effect of arrangement of wind turbines in a wind farm and safety factor used in design moorings is discussed.


2016 ◽  
Author(s):  
Amy Stidworthy ◽  
David Carruthers

Abstract. A new model, FLOWSTAR-Energy, has been developed for the practical calculation of wind farm energy production. It includes a semi-analytic model for airflow over complex surfaces (FLOWSTAR) and a wind turbine wake model that simulates wake-wake interaction by exploiting some similarities between the decay of a wind turbine wake and the dispersion of plume of passive gas emitted from an elevated source. Additional turbulence due to the wind shear at the wake edge is included and the assumption is made that wind turbines are only affected by wakes from upstream wind turbines. The model takes account of the structure of the atmospheric boundary layer, which means that the effect of atmospheric stability is included. A marine boundary layer scheme is also included to enable offshore as well as onshore sites to be modelled. FLOWSTAR-Energy has been used to model three different wind farms and the predicted energy output compared with measured data. Maps of wind speed and turbulence have also been calculated for two of the wind farms. The Tjaæreborg wind farm is an onshore site consisting of a single 2 MW wind turbine, the NoordZee offshore wind farm consists of 36 V90 VESTAS 3 MW turbines and the Nysted offshore wind farm consists of 72 Bonus 2.3 MW turbines. The NoordZee and Nysted measurement datasets include stability distribution data, which was included in the modelling. Of the two offshore wind farm datasets, the Noordzee dataset focuses on a single 5-degree wind direction sector and therefore only represents a limited number of measurements (1,284); whereas the Nysted dataset captures data for seven 5-degree wind direction sectors and represents a larger number of measurements (84,363). The best agreement between modelled and measured data was obtained with the Nysted dataset, with high correlation (0.98 or above) and low normalised mean square error (0.007 or below) for all three flow cases. The results from Tjæreborg show that the model replicates the Gaussian shape of the wake deficit two turbine diameters downstream of the turbine, but the lack of stability information in this dataset makes it difficult to draw conclusions about model performance. One of the key strengths of FLOWSTAR-Energy is its ability to model the effects of complex terrain on the airflow. However, although the airflow model has been previously compared extensively with flow data, it has so far not been used in detail to predict energy yields from wind farms in complex terrain. This will be the subject of a further validation study for FLOWSTAR-Energy.


Energies ◽  
2022 ◽  
Vol 15 (1) ◽  
pp. 282
Author(s):  
Feifei Xue ◽  
Heping Duan ◽  
Chang Xu ◽  
Xingxing Han ◽  
Yanqing Shangguan ◽  
...  

On a wind farm, the wake has an important impact on the performance of the wind turbines. For example, the wake of an upstream wind turbine affects the blade load and output power of the downstream wind turbine. In this paper, a modified actuator line model with blade tips, root loss, and an airfoil three-dimensional delayed stall was revised. This full-scale modified actuator line model with blades, nacelles, and towers, was combined with a Large Eddy Simulation, and then applied and validated based on an analysis of wind turbine wakes in wind farms. The modified actuator line model was verified using an experimental wind turbine. Subsequently, numerical simulations were conducted on two NREL 5 MW wind turbines with different staggered spacing to study the effect of the staggered spacing on the characteristics of wind turbines. The results show that the output power of the upstream turbine stabilized at 5.9 MW, and the output power of the downstream turbine increased. When the staggered spacing is R and 1.5R, both the power and thrust of the downstream turbine are severely reduced. However, the length of the peaks was significantly longer, which resulted in a long-term unstable power output. As the staggered spacing increased, the velocity in the central near wake of the downstream turbine also increased, and the recovery speed at the threshold of the wake slowed down. The modified actuator line model described herein can be used for the numerical simulation of wakes in wind farms.


2016 ◽  
Vol 1 (2) ◽  
pp. 327-340 ◽  
Author(s):  
Andrew Ning

Abstract. Actuator cylinder theory is an effective approach for analyzing the aerodynamic performance of vertical axis wind turbines at a conceptual design level. Existing actuator cylinder theory can analyze single turbines, but analysis of multiple turbines is often desirable because turbines may operate in near proximity within a wind farm. For vertical axis wind turbines, which tend to operate in closer proximity than do horizontal axis turbines, aerodynamic interactions may not be strictly confined to wake interactions. We modified actuator cylinder theory to permit the simultaneous solution of aerodynamic loading for any number of turbines. We also extended the theory to handle thrust coefficients outside of the momentum region and explicitly defined the additional terms needed for curved or swept blades. While the focus of this paper is a derivation of an extended methodology, an application of this theory was explored involving two turbines operating in close proximity. Comparisons were made against two-dimensional unsteady Reynolds-averaged Navier–Stokes (URANS) simulations, across a full 360° of inflow, with excellent agreement. The counter-rotating turbines produced a 5–10 % increase in power across a wide range of inflow conditions. A second comparison was made to a three-dimensional RANS simulation with a different turbine under different conditions. While only one data point was available, the agreement was reasonable, with the computational fluid dynamics (CFD) predicting a 12 % power loss, as compared to a 15 % power loss for the actuator cylinder method. This extended theory appears promising for conceptual design studies of closely spaced vertical axis wind turbines (VAWTs), but further development and validation is needed.


Author(s):  
Bryan E. Kaiser ◽  
Svetlana V. Poroseva ◽  
Michael A. Snider ◽  
Rob O. Hovsapian ◽  
Erick Johnson

A relatively high free stream wind velocity is required for conventional horizontal axis wind turbines (HAWTs) to generate power. This requirement significantly limits the area of land for viable onshore wind farm locations. To expand a potential for wind power generation and an area suitable for onshore wind farms, new wind turbine designs capable of wind energy harvesting at low wind speeds are currently in development. The aerodynamic characteristics of such wind turbines are notably different from industrial standards. The optimal wind farm layout for such turbines is also unknown. Accurate and reliable simulations of a flow around and behind a new wind turbine design should be conducted prior constructing a wind farm to determine optimal spacing of turbines on the farm. However, computations are expensive even for a flow around a single turbine. The goal of the current study is to determine a set of simulation parameters that allows one to conduct accurate and reliable simulations at a reasonable cost of computations. For this purpose, a sensitivity study on how the parameters variation influences the results of simulations is conducted. Specifically, the impact of a grid refinement, grid stretching, grid cell shape, and a choice of a turbulent model on the results of simulation of a flow around a mid-sized Rim Driven Wind Turbine (U.S. Patent 7399162) and in its near wake is analyzed. This wind turbine design was developed by Keuka Energy LLC. Since industry relies on commercial software for conducting flow simulations, STAR-CCM+ software [1] was used in our study. A choice of a turbulence model was made based on the results from our previous sensitivity study of flow simulations over a rotating disk [2].


2018 ◽  
Vol 43 (2) ◽  
pp. 201-209
Author(s):  
Gino Iannace ◽  
Amelia Trematerra ◽  
Umberto Berardi

In Italy, wind turbines with a nominal power below 1 MW can be installed following simplified authorization procedures and are therefore becoming the preferred choice for promoters. The assessment of the noise of wind farms is not easy, due to economic reasons, with it being difficult to stop and assess the relative contribution of each wind turbine. Several acoustic measurements were taken inside homes located near a wind farm consisting of three wind turbines, each with a nominal power of 1 MW. The acoustic measurements were taken by placing sound level meters inside the houses at different wind speed values and wind directions. The acoustic measurements were taken using the acoustically analogous place technique. For economic reasons, the plant cannot be switched off. In this case, the sound field generated by the operation of the wind turbines was measured by placing two sound level meters in a house.


Sign in / Sign up

Export Citation Format

Share Document