Film Cooling Jet Injection Effect in Heat Transfer Coefficient Augmentation for the Pressure Side Cooling of Turbine Vane

Author(s):  
Hossein Nadali Najafabadi ◽  
Matts Karlsson ◽  
Mats Kinell ◽  
Esa Utriainen

Improving film cooling performance of turbine vanes and blades is often achieved through application of multiple arrays of cooling holes on the suction side, the showerhead region and the pressure side. This study investigates the pressure side cooling under the influence of single and multiple rows of cooling in the presence of a showerhead from a heat transfer coefficient augmentation perspective. Experiments are conducted on a prototype turbine vane working at engine representative conditions. Transient IR thermography is used to measure time-resolved surface temperature and the semi-infinite method is utilized to calculate the heat transfer coefficient on a low conductive material. Investigations are performed for cylindrical and fan-shaped holes covering blowing ratio 0.6 and 1.8 at density ratio of about unity. The freestream turbulence is approximately 5% close to the leading edge. The resulting heat transfer coefficient enhancement, the ratio of HTC with to that without film cooling, from different case scenarios have been compared to showerhead cooling only. Findings of the study highlight the importance of showerhead cooling to be used with additional row of cooling on the pressure side in order to reduce heat transfer coefficient enhancement. In addition, it is shown that extra rows of cooling will not significantly influence heat transfer augmentation, regardless of the cooling hole shape.

Author(s):  
Tarek Elnady ◽  
Ibrahim Hassan

An experimental investigation has been performed to study the film cooling performance of a smooth expansion exit at the leading edge of a gas turbine vane. A two-dimensional cascade has been employed to measure the cooling performance of the proposed expansion using the transient Thermochromatic Liquid Crystal technique. One row of cylindrical holes, located on the stagnation line, is investigated with two expansion levels, 2d and 4d, in addition to the standard hole. The air is injected at 90° and 60° inclination angle relative to the vane surface at four blowing ratios ranging from 1 to 2 at a 0.9 density ratio. The Mach number and the Reynolds number based on the cascade exit velocity and the axial chord are 0.23 and 1.4E5, respectively. The detailed local heat transfer coefficient over both the pressure side and the suction side are presented in addition to the lateral-averaged normalized heat transfer coefficient. The proposed expansion provides a lower heat transfer coefficient compared with the standard cylindrical hole over the investigated blowing ratios. Combining the heat transfer coefficient with the corresponding cooling effectiveness, previously presented, the smooth expansion shows a significant reduction in the heat load with more uniform distribution of the coolant over the leading edge region. The strong confrontation between the coolant jet and the mainstream, in case of 90° injection, yields a strong dispersion of the coolant with higher heat transfer coefficient and high thermal load over the vane surface.


Author(s):  
Huitao Yang ◽  
Hamn-Ching Chen ◽  
Je-Chin Han ◽  
Hee-Koo Moon

Numerical simulations were performed to predict the film cooling effectiveness and the associated heat transfer coefficient on the leading edge of a rotating blade in a 1-1/2 turbine stage using a Reynolds stress turbulence model together with a non-equilibrium wall function. Simulations were performed for both the design and off-design conditions to investigate the effects of blade rotation on the leading edge film cooling effectiveness and heat transfer coefficient distributions. It was found that the tilt stagnation line on the leading edge of rotor moves from the pressure side to the suction side, and the instantaneous coolant streamlines shift from the suction side to the pressure side with increasing rotating speed. This trend was supported by the experimental results. The result also showed that the heat transfer coefficient increases, but film cooling effectiveness decreases with increasing rotating speed. In addition, the unsteady characteristics of the film cooling and heat transfer at different time phases, as well as different rotating speeds, were also reported.


Author(s):  
T. Elnady ◽  
I. Hassan ◽  
L. Kadem ◽  
T. Lucas

An experimental investigation has been performed to study the effect of hole shape and position on the cooling performance of a gas turbine stator. Two rows of laid-back fan-shaped holes are placed on the pressure side of a scaled vane in a two-dimensional cascade and compared with two identical rows of standard cylindrical exit. Both hole shapes have the same base diameter and were investigated at three different blowing ratios (1, 1.35, and 1.7) with the same coolant flow rate used in each case. The experiments are conducted for the first row of holes only, then for the second row only, and finally for both two rows together at a 0.9 density ratio. The mainstream inlet Reynolds number based on the true chord is 1.4E5 and the exit Mach number is 0.23. The local distributions of the heat transfer coefficient and film cooling effectiveness are obtained using a transient TLC technique. The second row of holes, with by a higher local radius of curvature, shows a 40% decrease in the cooling effectiveness as well as a 10% increase in the heat transfer coefficient near downstream of the hole compared with that obtained by the first hole. The double injection provides a slight increase in the cooling effectiveness and a lower heat transfer coefficient due to the favorable interaction between both injections.


Author(s):  
Chun-yi Yao ◽  
Hui-ren Zhu ◽  
Cun-liang Liu ◽  
Bo-lun Zhang ◽  
Xin-lei Li

Abstract A number of experimental studies have been performed to study the effect of geometric and aerodynamic parameters on the film cooling performance on the flat plate and turbine blade, however, the experimental investigations on a fully-cooled turbine vane is limited, especially at different density ratios. Consequently, an experiment on a fully-cooled turbine vane with multi-row film cooling holes was carried out to investigate the effect of mass flow ratio and density ratio on the film cooling performance, in which the film cooling effectiveness and heat transfer coefficient was measured by transient liquid crystal. The mainstream inlet Reynolds number based on the inlet velocity and the true chord length is 120000 and the mainstream turbulence intensity is 15%, three mass flow ratios of 5.5%, 8.4% and 11% and two density ratios of 1.0 and 1.5 were tested. The air was selected as the mainstream, the air and carbon dioxide were independently selected as secondary flow to produce two density ratios of 1.0 and 1.5. The test vane is similar in geometry to a first stage turbine vane of a normal aeroengine. Two cavities were manufactured in the test vane to feed 18 rows of film cooling holes. Results show that with the mass flow ratio increasing for DR = 1.0 and 1.5, the film cooling effectiveness on pressure side gradually increases, however, that on the suction side gradually decreases. Generally, increased density ratio produces higher film cooling effectiveness because the injection momentum was reduced, however, the film cooling effectiveness on the suction side for DR = 1.5 is lower than that for DR = 1.0. The coolant outflow significantly enhances the surface heat transfer coefficient for 0 < S/C < 0.5 and S/C < −0.5. The heat transfer coefficient in the leading edge is less affected by the density ratio, however, the increase in density ratio reduces the heat transfer coefficient ratio in other regions, especially for large mass flow ratios.


Author(s):  
Chunyi Yao ◽  
Zheng Zhang ◽  
Bo-lun Zhang ◽  
Hui Ren Zhu ◽  
Cun Liang Liu

Abstract The objective of this experimental investigation was to determine the cooling performance of a fully cooled vane with 18 rows of cylinder cooling holes. The exit Reynolds number in the wind tunnel normalized by the true chord was 500,000 with a turbulence intensity of 15%. The film cooling effectiveness and heat transfer coefficient distribution were obtained by the transient liquid crystal technology, three mass flow ratios (MFR=7.0%, 9.9%, 11%) and two density ratios (DR=1.0, 1.5) were tested. The results show that the film cooling effectiveness distribution on the suction side is more uniform and the coolant injection trajectory is much longer than that on the pressure side. As the density ratio increasing to 1.5, the more laterally uniform film cooling effectiveness contour on the pressure side is observed and the spatially averaged film cooling effectiveness is increased by 11%∼43%. For the MFR=7.0%, the coolant injection with low momentum thickens the boundary layer and reduces the heat transfer coefficient in the mid-chord region of the pressure side. Both the increased mass flow ratio and decreased density ratio result in a higher heat transfer coefficient, while do not alter the distribution trend. By calculating the heat flux ratio, the reduction in the heat flux at DR=1.5 is found to be within 20% in most areas than that of DR=1.0 on the vane surface.


2018 ◽  
Vol 35 (3) ◽  
pp. 291-303 ◽  
Author(s):  
Cun-Liang Liu ◽  
Dan Zhao ◽  
Ying-Ni Zhai ◽  
Hui-Ren Zhu ◽  
Yi-Hong He ◽  
...  

AbstractNumerical simulations have been performed on the film cooling characteristics of counter-inclined structures, which have advantage in manufacturing relative to the usually used parallel-inclined film-hole row structure, on a turbine vane leading edge model. Single row structure and dual-row structure with counter-inclined film holes were applied in the simulation of leading edge film cooling of turbine vane. The effect of jet-interaction between counter-inclined film-hole rows was studied. The distributions of film cooling effectiveness and heat transfer coefficient were obtained at blowing ratios of 1.0 and 2.0. The results of single row structure show that the film cooling performances of counter-inclined film-hole row are not weakened compared to the traditional parallel-inclined film-hole row structure. The film cooling effectiveness of the counter-inclined film-hole row structure decreases with the increase of blowing ratio, while the heat transfer coefficient increases. The jet-interaction in the dual-row film cooling structure has more notable influence on the film cooling effectiveness than the heat transfer coefficient. Compared to the single row case, the interactions between the upstream counter-blowing jets and the downstream jet improve the film coverage performance and reduce the heat transfer intensity of this downstream jet under larger blowing ratio condition.


Author(s):  
James L. Rutledge

It is necessary to understand how film cooling both reduces the adiabatic wall temperature and influences the heat transfer coefficient in order to predict the net heat flux to a gas turbine hot gas path component. Although a great number of studies have considered steady film cooling flows, the influence of film cooling unsteadiness has only recently been considered. Unsteadiness in the freestream flow or the coolant flow can cause fluctuations in both the adiabatic effectiveness and heat transfer coefficient, the dynamics of which have been difficult to measure. In previous studies, only time averaged effects have been measured. The present study has determined time resolved adiabatic effectiveness and heat transfer coefficient waveforms using a novel inverse heat transfer methodology. Unsteady film cooling was examined on the leading edge region of a circular cylinder simulating the leading edge of a turbine blade. Unsteady interactions between h and η, were examined near a coolant hole located 21.5° downstream from the leading edge stagnation line, angled 20° to the surface and 90° to the streamwise direction. The coolant plume is shown to shift back and forth as the jet’s momentum fluctuates. Increasing freestream turbulence was found to both reduce η, and the amplitude of the η waveforms.


Author(s):  
Mats Kinell ◽  
Esa Utriainen ◽  
Hossein Nadali Najafabadi ◽  
Matts Karlsson ◽  
Botond Barabas

In order to protect a solid surface exposed to high temperature gaseous flows, e.g. gas turbines and rocket engines, a second gas at lower temperature may be introduced into the hot boundary layer, i.e. one obtains a three temperature problem. The impact of the film cooling on a prototype vane due to variation in blowing ratio, the shape of the hole-outlet and position has been experimentally investigated. The semi-infinite and low conductive test object, initially at a uniform temperature, was exposed to a sudden step change in main flow temperature and a time-resolved surface temperature was measured using an IR camera. By assuming constant values of the heat transfer coefficient and the film cooling effectiveness over time, the heat equation was solved using least squares. The prototype vane was tested for different film cooling row positions on the pressure and suction side. Both cylindrical as well as fan shaped holes were investigated with and without showerhead cooling. The resulting heat transfer coefficient and film cooling effectiveness on the pressure side is compared to flat plate studies and to the results from the suction side. Also, the applicability of using superposition on showerhead cooling and on single/double rows is investigated. Furthermore, the results are compared to other published airfoil film cooling experiments and to CFD analysis for which conclusions are drawn on quantitative and qualitative capabilities of this tool.


2004 ◽  
Vol 10 (5) ◽  
pp. 345-354 ◽  
Author(s):  
Jan Dittmar ◽  
Achmed Schulz ◽  
Sigmar Wittig

The demand of improved thermal efficiency and high power output of modern gas turbine engines leads to extremely high turbine inlet temperature and pressure ratios. Sophisticated cooling schemes including film cooling are widely used to protect the vanes and blades of the first stages from failure and to achieve high component lifetimes. In film cooling applications, injection from discrete holes is commonly used to generate a coolant film on the blade's surface.In the present experimental study, the film cooling performance in terms of the adiabatic film cooling effectiveness and the heat transfer coefficient of two different injection configurations are investigated. Measurements have been made using a single row of fanshaped holes and a double row of cylindrical holes in staggered arrangement. A scaled test model was designed in order to simulate a realistic distribution of Reynolds number and acceleration parameter along the pressure side surface of an actual turbine guide vane. An infrared thermography measurement system is used to determine highly resolved distribution of the models surface temperature. Anin-situcalibration procedure is applied using single embedded thermocouples inside the measuring plate in order to acquire accurate local temperature data.All holes are inclined 35° with respect to the model's surface and are oriented in a streamwise direction with no compound angle applied. During the measurements, the influence of blowing ratio and mainstream turbulence level on the adiabatic film cooling effectiveness and heat transfer coefficient is investigated for both of the injection configurations.


Author(s):  
Bo-lun Zhang ◽  
Li Zhang ◽  
Hui-ren Zhu ◽  
Jian-sheng Wei ◽  
Zhong-yi Fu

Film cooling performance of the double-wave trench was numerically studied to improve the film cooling characteristics. Double-wave trench was formed by changing the leading edge and trailing edge of transverse trench into cosine wave. The film cooling characteristics of transverse trench and double-wave trench were numerically studied using Reynolds Averaged Navier Stokes (RANS) simulations with realizable k-ε turbulence model and enhanced wall treatment. The film cooling effectiveness and heat transfer coefficient of double-wave trench at different trench width (W = 0.8D, 1.4D, 2.1D) conditions are investigated, and the distribution of temperature field and flow field were analyzed. The results show that double-wave trench effectively improves the film cooling effectiveness and the uniformity of jet at the downstream wall of the trench. The span-wise averaged film cooling effectiveness of the double-wave trench model increases 20–63% comparing with that of the transverse trench at high blowing ratio. The anti-counter-rotating vortices which can press the film on near-wall are formed at the downstream wall of the double-wave trench. With the double-wave trench width decreasing, the film cooling effectiveness gradually reduces at the hole center-line region of the downstream trench. With the increase of the blowing ratio, the span-wise averaged heat transfer coefficient increases. The span-wise averaged heat transfer coefficient of the double-wave trench with 0.8D and 2.1D trench width is higher than that of the double-wave trench with 1.4D trench width at the high blowing ratio conditions.


Sign in / Sign up

Export Citation Format

Share Document