A Proposal for Passive Wall Treatment Applied in High Performance Axial Flow Compressors

Author(s):  
Rubén Bruno Díaz ◽  
Jesuino Takachi Tomita ◽  
Cleverson Bringhenti ◽  
Francisco Carlos Elizio de Paula ◽  
Luiz Henrique Lindquist Whitacker

Abstract Numerical simulations were carried out with the purpose of investigating the effect of applying circumferential grooves at axial compressor casing passive wall treatment to enhance the stall margin and change the tip leakage flow. The tip leakage flow is pointed out as one of the main contributors to stall inception in axial compressors. Hence, it is of major importance to treat appropriately the flow in this region. Circumferential grooves have shown a good performance in enhancing the stall margin in previous researches by changing the flow path in the tip clearance region. In this work, a passive wall treatment with four circumferential grooves was applied in the transonic axial compressor NASA Rotor 37. Its effect on the axial compressor performance and the flow in the tip clearance region was analyzed and set against the results attained for the smooth wall case. A 2.63% increase in the operational range of the axial compressor running at 100%N, was achieved, when compared with the original smooth wall casing configuration. The grooves installed at compressor casing, causes an increase in the flow entropy generation due to the high viscous effects in this gap region, between the rotor tip surface and casing with grooves. These viscous effects cause a drop in the turbomachine efficiency. For the grooves configurations used in this work, an efficiency drop of 0.7% was observed, compared with the original smooth wall. All the simulations were performed based on 3D turbulent flow calculations using Reynolds Averaged Navier-Stokes equations, and the flow eddy viscosity was determined using the two-equation SST turbulence model. The details of the grooves geometrical dimensions and its implementation are described in the paper.

Author(s):  
Jichao Li ◽  
Feng Lin ◽  
Sichen Wang ◽  
Juan Du ◽  
Chaoqun Nie ◽  
...  

Circumferential single-groove casing treatment becomes an interesting topic in recent few years, because it is a good tool to explore the interaction between the groove and the flow in blade tip region. The stall margin improvement (SMI) as a function of the axial groove location has been found for some compressors, such a trend cannot be predicted by steady high-fidelity CFD simulations. Recent efforts show that to catch such a trend, multi-passage, unsteady flow simulations are needed as the stalling mechanism itself involves cross-passage flows and unsteady dynamics. This indicates a need to validate unsteady numerical simulation results. In this paper, an extensive experimental study of a total of fifteen single casing grooves in a low-speed axial compressor rotor is presented, the groove location varies from 0.4% to 98.3% of axial tip chord are tested. The unsteady pressure data both at casing and at the blade wake with different groove locations are measured and processed, including the movement of trajectory of tip leakage flow, the evolution of unsteadiness of tip leakage flow (UTLF), the unsteady spectrum signature during the stall process, and the outlet unsteady flow characteristic along the span. These data provide a case study for validation of the unsteady CFD results, and may be helpful for further interpretation on the stalling mechanism affected by circumferential casing grooves.


Author(s):  
Haohao Zhang ◽  
Haowan Zhuang ◽  
Jinfang Teng ◽  
Mingmin Zhu ◽  
Xiaoqing Qiang

A steady and unsteady numerical research is carried out to explore some effects of a specific non-axisymmetric tip clearance layout on the overall performance and stability of an axial compressor stage. For a 4-stage low-speed research compressor (LSRC) in Shanghai Jiao Tong University (SJTU), one-eighth annulus of the inlet guide vane and the first stage rotor was modeled for this study. After the validation for the uniform tip clearance case, a specific non-axisymmetric tip clearance layout is chosen from several random cases generated by the Gaussian Probabilistic Density Function method. Unsteady time-averaged results at the near stall condition show that the chosen non-axisymmetric layout can improve the isentropic efficiency by 1.3% and extend the stall margin by 4%. Detailed analyses on flow fields are carried out to interpret the performance improvement. Due to the circumferential layout of clearance sizes, the inlet mass flow and incidence are redistributed in both the radial and circumferential directions. It leads to blade loading and tip leakage flow varying with the tip clearance size. The quantification of blockage manifests that the blockage arising from the tip leakage flow is significantly alleviated in the non-axisymmetric layout, which leads to improvements in overall performance and stall margin. Transient flow fields at the rotor tip are also analyzed at the near stall condition. For the non-axisymmetric layout, low-momentum regions originating from larger clearance sizes oscillate and develop downstream in one blade passage period.


Author(s):  
Shraman Goswami ◽  
Ashima Malhotra

Abstract Performance of an axial compressor rotor depends largely on the tip leakage flow. Tip leakage flow results in tip leakage vortex which is a source of loss. This has an impact on the compressor efficiency as well as stall margin. A lot of work has been done to understand the tip leakage flow and controlling the same. Active and passive stall margin improvement methods mainly target the tip leakage vortex. In the current study, numerical investigations are carried out to understand flow fields near tip region of rotors. The blade tip designed to have a tip gap as sine and cosine waves (single and double waves). Numerical methodology is validated with NASA Rotor37 test results. The performance parameters of the rotors with modified tip gap shapes are compared with constant tip clearance rotor. A detailed flow field investigation is presented to compare the tip flow structure and its impact on overall performance of the compressor.


Energies ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 4168
Author(s):  
Botao Zhang ◽  
Xiaochen Mao ◽  
Xiaoxiong Wu ◽  
Bo Liu

To explain the effect of tip leakage flow on the performance of an axial-flow transonic compressor, the compressors with different rotor tip clearances were studied numerically. The results show that as the rotor tip clearance increases, the leakage flow intensity is increased, the shock wave position is moved backward, and the interaction between the tip leakage vortex and shock wave is intensified, while that between the boundary layer and shock wave is weakened. Most of all, the stall mechanisms of the compressors with varying rotor tip clearances are different. The clearance leakage flow is the main cause of the rotating stall under large rotor tip clearance. However, the stall form for the compressor with half of the designed tip clearance is caused by the joint action of the rotor tip stall caused by the leakage flow spillage at the blade leading edge and the whole blade span stall caused by the separation of the boundary layer of the rotor and the stator passage. Within the investigated varied range, when the rotor tip clearance size is half of the design, the compressor performance is improved best, and the peak efficiency and stall margin are increased by 0.2% and 3.5%, respectively.


Author(s):  
Young-Jin Jung ◽  
Tae-Gon Kim ◽  
Minsuk Choi

This paper addresses the effect of the recessed blade tip with and without a porous material on the performance of a transonic axial compressor. A commercial flow solver was employed to analyze the performance and the internal flow of the axial compressor with three different tip configurations: reference tip, recessed tip and recessed tip filled with a porous material. It was confirmed that the recessed blade tip is an effective method to increase the stall margin in an axial compressor. It was also found in the present study that the strong vortex formed in the recess cavity on the tip pushed the tip leakage flow backward and weakened the tip leakage flow itself, consequently increasing the stall margin without any penalty of the efficiency in comparison to the reference tip. The recessed blade tip filled with a porous material was suggested with hope to obtain the larger stall margin and the higher efficiency. However, it was found that a porous material in the recess cavity is unfavorable to the performance in both the stall margin and the efficiency. An attempt has been made to explain the effect of the recess cavity with and without a porous material on the flow in an axial compressor.


Author(s):  
Tian Liang ◽  
Bo Liu ◽  
Stephen Spence ◽  
Liying Jiao

To extend the current understanding of the circumferential groove casing suction applied to a counter-rotating axial flow compressor, the impact of different axial locations of the circumferential suction groove on the characteristics of the tip leakage flow (TLF) and the corresponding physical mechanisms producing the stability enhancement have been studied based on validated numerical simulations. The results show that the optimal location for the suction groove is at around 20% axial chord, which demonstrated a high potential for reducing additional stall mass flow coefficient with about 8.4% increment in the stall margin. After the casing suction groove was applied, the interface between the incoming main flow and TLF was pushed significantly downstream in the second rotor. The blade loading in the region below the groove, the tip leakage flow angle and the reversed axial momentum flux injected into main flow passage through the tip gap were all reduced, which contributed to the stall margin improvement. Detailed analysis of the tip leakage flow structures showed that the TLF originating from different chord locations played different roles in the stall inception process. It was found to be more effective to improve stall margin and adiabatic efficiency by controlling the front part of the TLF, which was most sensitive.


1991 ◽  
Vol 113 (2) ◽  
pp. 252-259 ◽  
Author(s):  
J. A. Storer ◽  
N. A. Cumpsty

Experimental measurements in a linear cascade with tip clearance are complemented by numerical solutions of the three-dimensional Navier–Stokes equations in an investigation of tip leakage flow. Measurements reveal that the clearance flow, which separates near the entry of the tip gap, remains unattached for the majority of the blade chord when the tip clearance is similar to that typical of a machine. The numerical predictions of leakage flow rate agree very well with measurements, and detailed comparisons show that the mechanism of tip leakage is primarily inviscid. It is demonstrated by simple calculation that it is the static pressure field near the end of the blade that controls chordwise distribution of the flow across the tip. Although the presence of a vortex caused by the roll-up of the leakage flow may affect the local pressure field, the overall magnitude of the tip leakage flow remains strongly related to the aerodynamic loading of the blades.


Author(s):  
Yanhui Wu ◽  
Wuli Chu ◽  
Xingen Lu ◽  
Junqiang Zhu

The current paper reports on investigations with an aim to advance the understanding of the flow field near the casing of a small-scale high-speed axial flow compressor rotor. Steady three dimensional viscous flow calculations are applied to obtain flow fields at various operating conditions. To demonstrate the validity of the computation, the numerical results are first compared with available measured data. Then, the numerically obtained flow fields are analyzed to identify the behavior of tip leakage flow, and the mechanism of blockage generation arising from flow interactions between the tip clearance flow, the blade/casing wall boundary layers, and non-uniform main flow. The current investigation indicates that the “breakdown” of the tip leakage vortex occurs inside the rotor passage at the near stall condition. The vortex “breakdown” results in the low-energy fluid accumulating on the casing wall spreads out remarkably, which causes a sudden growth of the casing wall boundary layer having a large blockage effect. A low-velocity region develops along the tip clearance vortex at the near stall condition due to the vortex “breakdown”. As the mass flow rate is further decreased, this area builds up rapidly and moves upstream. This area prevents incoming flow from passing through the pressure side of the passage and forces the tip leakage flow to spill into the adjacent blade passage from the pressure side at the leading edge. It is found that the tip leakage flow exerts little influence on the development of the blade suction surface boundary layer even at the near stall condition.


Author(s):  
Hark-Jin Eum ◽  
Shin-Hyoung Kang

Effects of tip clearance on through flows and performance of a centrifugal compressor impeller with six different tip clearances were numerically studied using CFX-TASCflow. The flow structures inside the impeller of a centrifugal compressor were visualized observing streamlines starting the leading edge of blade tips. The calculated results at the impeller exit were circumferential averaged for quantitative discussion. Flow, pressure and entropy contours at the impeller exit were largely influenced by the tip leakage flow. Tip clearance effect on the performance was decomposed into inviscid and viscous components using one-dimensional relations expressed in terms of the specific work reduction and the additional entropy generation. Both inviscid and viscous effects affected performance to similar extent, while efficiency drop was mainly influenced by viscous loss of the tip leakage flow. Performance reduction and efficiency drop due to tip clearance was proportional to the ratio of tip clearance to blade height. A simple model suggested in the present study predicts performance and efficiency drop quite successfully.


2013 ◽  
Vol 135 (5) ◽  
Author(s):  
Joshua D. Cameron ◽  
Matthew A. Bennington ◽  
Mark H. Ross ◽  
Scott C. Morris ◽  
Juan Du ◽  
...  

Experimental and numerical studies were conducted to investigate tip-leakage flow and its relationship to stall in a transonic axial compressor. The computational fluid dynamics (CFD) results were used to identify the existence of an interface between the approach flow and the tip-leakage flow. The experiments used a surface-streaking visualization method to identify the time-averaged location of this interface as a line of zero axial shear stress at the casing. The axial position of this line, denoted xzs, moved upstream with decreasing flow coefficient in both the experiments and computations. The line was consistently located at the rotor leading edge plane at the stalling flow coefficient, regardless of inflow boundary condition. These results were successfully modeled using a control volume approach that balanced the reverse axial momentum flux of the tip-leakage flow with the momentum flux of the approach fluid. Nonuniform tip clearance measurements demonstrated that movement of the interface upstream of the rotor leading edge plane leads to the generation of short length scale rotating disturbances. Therefore, stall was interpreted as a critical point in the momentum flux balance of the approach flow and the reverse axial momentum flux of the tip-leakage flow.


Sign in / Sign up

Export Citation Format

Share Document