Experimental Investigation of Adiabatic Film Cooling Effectiveness Over a Circular Fan and Laidback Fan Shaped Hole Flat Plate Test Models

Author(s):  
Giridhara Babu Yepuri ◽  
Felix Jesuraj ◽  
Suresh Batchu ◽  
Kesavan Venkataraman

The experimental investigation of adiabatic film cooling effectiveness is carried out on a flat plates with 4:1 scaled up hole geometries, similar to that of typical turbine nozzle guide vane film cooling holes. Under this study, three flat plate models are considered with the two rows of holes having circular, fan and laidback fan shapes arranged in a staggered manner. These flat plate models are generated using solid works design software and fabricated using low thermal conductivity nylon based material using RPT technique. The mass flow results indicated the average nominal coefficient of discharge for the cooling holes as 0.71, for all these three models based on the inlet hole area and length of the holes. The laterally averaged adiabatic film cooling effectiveness is found along the stream wise direction at a density ratio of 1.62 by varying the blowing ratio in the range of 0.5 to 2.5. The surface temperatures of the test models are captured using the infrared camera, to evaluate the film cooling effectiveness. The experimentally evaluated results shows that, there is no increase in cooling effectiveness for the blowing ratio of 2.0 to 2.5 in the stream wise direction up to the X/d of 25 and there is a marginal increase above the X/d of 25 in the cases of these type of two row circular and Fan shaped hole models. Where as in the Laidback fan shaped hole model, the increase in cooling effectiveness is found significant up to the blowing ratio of 2.5 in the considered range. From the comparative results of adiabatic film cooling effectiveness of these three models, the laidback fan shaped hole model shows the higher film cooling effectiveness than the circular and fan shaped holes model at all the considered blowing ratios.

Author(s):  
Chao Zhang ◽  
Jie Wang ◽  
Xin Luo ◽  
Liming Song ◽  
Jun Li ◽  
...  

Abstract In our experiments, the film cooling performance of the configurations combined the different hole with the vortex generator was investigated experimentally, measured by the infrared camera. Four different configurations were studied at the blowing ratio varying at M = 0.5, 1.0, 1.5, 2.0, 2.5 and 3.0. In all cases, the Reynold number of the mainstream based on the hole diameter remained at Re = 8000, and the density ratio kept at DR = 1.7. Experimental results show that for the two models combining the cylindrical hole and fan-shaped hole with the vortex generator respectively, the film cooling performance becomes better when the blowing ratio increases from M = 0.5 to M = 2.0, and then decreases when the blowing ratio increases from M = 2.0 to M = 3.0. The model combining the fan-shaped hole with the vortex generator performs the best among the four models at each blowing ratio. Its film attachment holds the most extensive lateral distribution and its overall film cooling effectiveness could keep at a high level at a wide range of blowing ratios from M = 1.0 to M = 3.0. The combined model of the fan-shaped hole could improve the area-averaged film effectiveness at most 25.5% than that of the single hole model at M = 2.0. Moreover, the combined model of the cylindrical hole could improve the area-averaged film cooling effectiveness at most 431% than that of the single cylindrical hole model at M = 3.0.


Energies ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3573
Author(s):  
Soo-In Lee ◽  
Jin-Young Jung ◽  
Yu-Jin Song ◽  
Jae-Su Kwak

In this study, the effect of mainstream velocity on the optimization of a fan-shaped hole on a flat plate was experimentally investigated. The experiment was conducted by changing the forward expansion angle (βfwd), lateral expansion angle (βlat), and metering length ratio (Lm/D) of the film-cooling hole. A total of 13 cases extracted using the Box–Behnken method were considered to examine the effect of the shape parameters of the film-cooling hole under a 90 m/s mainstream velocity condition, and the results were compared with the results derived under a mainstream velocity of 20 m/s. One density ratio (DR = 2.0) and a blowing ratio (M) ranging from 1.0 to 2.5 were considered, and the pressure-sensitive paint (PSP) technique was applied for the film-cooling effectiveness (FCE). As a result of the experiment, the optimized hole showed a 49.3% improvement in the overall averaged FCE compared to the reference hole with DR = 2.0 and M = 2.0. As the blowing ratio increased, the hole exit area tended to increase, and this tendency was the same as that in the 20 m/s mainstream condition.


2021 ◽  
Author(s):  
Jie Wang ◽  
Chao Zhang ◽  
Xuebin Liu ◽  
Liming Song ◽  
Jun Li ◽  
...  

Abstract Aiming at investigating the effects of crossflow and vortex generator on film cooling characteristics of fan-shaped hole, the film cooling performance was measured experimentally by infrared camera. The blowing ratio is fixed at 0.5 and 1.5. The Reynolds number of the mainstream based on the hole diameter remains at 7000 and the inlet Reynolds number of crossflow is 40000. The experimental results show that the film cooling performance becomes better when the blowing ratio increases from 0.5 to 1.5 for each model, and the film cooling performance becomes worse under the influence of crossflow. When the blowing ratio is 1.5, the area-averaged film cooling effectiveness of the fan-shaped hole model with vortex generator decreases by 16.6% because of the influence of crossflow. The combined model always performs better compared with the model without vortex generator under all working conditions. When the blowing ratio becomes 1.5, under the influence of crossflow, the area-averaged film cooling effectiveness of the combined model could increase by 14.8%, compared with the model without vortex generator. To further improve the film cooling performance, the global optimization algorithm based on the Kriging method and the CFD technology are coupled to optimize the combined model under crossflow condition at the high blowing ratio, and the optimized design is verified by experiments. The experimental results show that the area-averaged film cooling effectiveness of the optimized design increases by 17.8% compared with the reference model.


Author(s):  
Bai-Tao An ◽  
Jian-Jun Liu ◽  
Si-Jing Zhou ◽  
Xiao-Dong Zhang ◽  
Chao Zhang

This paper presents a new configuration of discrete film hole, i.e., the slot-based diffusion hole. Retaining the similar diffusion features to a traditional diffusion hole, the slot-based diffusion hole transforms the cross section of circle for the traditional diffusion hole to a flattened rectangle with respect to the equivalent cross-sectional area. Consequently, the exit width of the new hole is effectively enlarged. To verify the film cooling effectiveness, a low speed flat plate experimental facility incorporated with Pressure Sensitive Paint (PSP) measurement technique was employed to obtain the adiabatic film cooling effectiveness. The experiments were performed with hole pitch to diameter ratio p/D=6 and density ratio DR=1.38. The blowing ratio was varied from M=0.5 to M=2.5. A fan-shaped hole and two slot-based diffusion holes were tested and compared. Three-dimensional numerical simulation was employed to analyze the flow field in detail. The experimental results showed that the area averaged effectiveness of two slot-based diffusion holes is significantly higher than that of the fan-shaped hole when the blowing ratio exceeds 1.0. The slot-based diffusion hole demonstrates the great advantage over the fan-shaped hole at hole exit and maintains this to far downstream. The numerical results showed that the ends shape of the flattened rectangular cross section has large influences on film distribution patterns and downstream vortex structures. The semi-circle and straight line ends shapes lead to a bi-peak and a single-peak effectiveness pattern, respectively. The optimal ends shape can regulate the vortex structures and improve the film cooling effectiveness further.


Author(s):  
Kyle R. Vinton ◽  
Travis B. Watson ◽  
Lesley M. Wright ◽  
Daniel C. Crites ◽  
Mark C. Morris ◽  
...  

The combined effects of a favorable, mainstream pressure gradient and coolant-to-mainstream density ratio have been investigated. Detailed film cooling effectiveness distributions have been obtained on a flat plate with either cylindrical (θ = 30°) or laidback, fan-shaped holes (θ = 30°, β = γ = 10°) using the pressure sensitive paint (PSP) technique. In a low speed wind tunnel, both non-accelerating and accelerating flows were considered while the density ratio varied from 1–4. In addition, the effect of blowing ratio was considered, with this ratio varying from 0.5 to 1.5. The film produced by the shaped hole outperformed the round hole under the presence of a favorable pressure gradient for all blowing and density ratios. At the lowest blowing ratio, in the absence of freestream acceleration, the round holes outperformed the shaped holes. However, as the blowing ratio increases, the shaped holes prevent lift-off of the coolant and offer enhanced protection. The effectiveness afforded by both the cylindrical and shaped holes, with and without freestream acceleration, increased with density ratio.


Author(s):  
Kevin Liu ◽  
Shang-Feng Yang ◽  
Je-Chin Han

Adiabatic film-cooling effectiveness is examined systematically on a typical high pressure turbine blade by varying three critical flow parameters: coolant blowing ratio, coolant-to-mainstream density ratio, and freestream turbulence intensity. Three average coolant blowing ratios 1.0, 1.5, and 2.0; three coolant density ratios 1.0, 1.5, and 2.0; two turbulence intensities 4.2% and 10.5%, are chosen for this study. Conduction-free pressure sensitive paint (PSP) technique is used to measure film-cooling effectiveness. Three foreign gases — N2 for low density, CO2 for medium density, and a mixture of SF6 and Argon for high density are selected to study the effect of coolant density. The test blade features 45° compound-angle shaped holes on the suction side and pressure side, and 3 rows of 30° radial-angle cylindrical holes around the leading edge region. The inlet and the exit Mach number are 0.27 and 0.44, respectively. Reynolds number based on the exit velocity and blade axial chord length is 750,000. Results reveal that the PSP is a powerful technique capable of producing clear and detailed film effectiveness contours with diverse foreign gases. As blowing ratio exceeds the optimum value, it induces more mixing of coolant and mainstream. Thus film-cooling effectiveness reduces. Greater coolant-to-mainstream density ratio results in lower coolant-to-mainstream momentum and prevents coolant to lift-off; as a result, film-cooling increases. Higher freestream turbulence causes effectiveness to drop everywhere except in the region downstream of suction side. Results are also correlated with momentum flux ratio and compared with previous studies. It shows that compound shaped hole has the greatest optimum momentum flux ratio, and then followed by axial shaped hole, compound cylindrical hole, and axial cylindrical hole.


Author(s):  
Siavash Khajehhasani ◽  
Bassam A. Jubran

The film cooling performance using novel sister shaped single-hole (SSSH) schemes are numerically investigated in the present study. The downstream, upstream and up/downstream SSSH configurations are formed by merging the discrete sister holes to the primary injection hole through a series of specific orientations. The obtained results are compared with a conventional cylindrical hole and a forward diffused shaped hole. The RANS simulations are performed using the realizable k-ε model with the standard wall function. Results are presented for low and high blowing ratios of 0.25 and 1.5, respectively. The film cooling effectiveness is notably increased for the novel shaped holes, particularly at the high blowing ratio of 1.5. Furthermore, a considerable decrease in the jet lift-off has been achieved for the proposed film hole geometries, wherein fully attached flow to the wall surface is observed for the upstream and up/downstream SSSH schemes.


Author(s):  
Lesley M. Wright ◽  
Evan L. Martin

Detailed film cooling effectiveness distributions are obtained on a flat plate using the pressure sensitive paint (PSP) technique. The effects of average blowing ratio (M = 0.25–1.0) and coolant – to – mainstream density ratio (DR = 1.0–1.4) are evaluated in a low speed wind tunnel with a freestream velocity of 8.5 m/s and a freestream turbulence intensity of 6.8%. The coolant – to – mainstream density ratio is varied by using either nitrogen (DR = 1.0) or argon (DR = 1.4) as the coolant gases. The double hole geometry consists of a row of simple angle (θ = 35°), cylindrical holes coupled with one row of compound angle holes (θ = 45°, β = 50°). With the selected geometry, the compound holes effectively weaken the counter rotating vortex pair formed within the traditional simple angle hole. Therefore, the surface film cooling effectiveness is increased compared to a single row of simple angle film cooling holes. While increasing the blowing ratio decreases the film cooling effectiveness, the severity of the film cooling effectiveness reduction is less than with the single row of holes.


2019 ◽  
Vol 141 (4) ◽  
Author(s):  
Nian Wang ◽  
Mingjie Zhang ◽  
Chao-Cheng Shiau ◽  
Je-Chin Han

This study investigates the effects of blowing ratio, density ratio, and spanwise pitch on the flat plate film cooling from two rows of compound angled cylindrical holes. Two arrangements of two-row compound angled cylindrical holes are tested: (a) the first row and the second row are oriented in staggered and same compound angled direction (β = +45 deg for the first row and +45 deg for the second row); (b) the first row and the second row are oriented in inline and opposite direction (β = +45 deg for the first row and −45 deg for the second row). The cooling hole is 4 mm in diameter with an inclined angle of 30 deg. The streamwise row-to-row spacing is fixed at 3d, and the spanwise hole-to-hole (p) is varying from 4d, 6d to 8d for both designs. The film cooling effectiveness measurements were performed in a low-speed wind tunnel in which the turbulence intensity is kept at 6%. There are 36 cases for each design including four blowing ratios (M = 0.5, 1.0, 1.5, and 2.0), three density ratios (DR = 1.0, 1.5, and 2.0), and three hole-to-hole spacing (p/d = 4, 6, and 8). The detailed film cooling effectiveness distributions were obtained by using the steady-state pressure-sensitive paint (PSP) technique. The spanwise-averaged cooling effectiveness are compared over the range of flow parameters. Some interesting observations are discovered including blowing ratio effect strongly depending on geometric design; staggered arrangement of the hole with same orientation does not yield better effectiveness at higher blowing ratio. Currently, film cooling effectiveness correlation of two-row compound angled cylindrical holes is not available, so this study developed the correlations for the inline arrangement of holes with opposing angles and the staggered arrangement of holes with same angles. The results and correlations are expected to provide useful information for the two-row flat plate film cooling analysis.


2021 ◽  
pp. 1-28
Author(s):  
Zhi-Qiang Yu ◽  
Jianjun Liu ◽  
Chen Li ◽  
Baitao An ◽  
Guang-Yao Xu

Abstract This paper focuses on the influences of the discrete hole shape and layout on the blade endwall film cooling effectiveness. The diffusion slot hole was first applied to the blade endwall and compared with the fan-shaped hole. The effect of upstream purge slot injection on the film cooling performance of the discrete hole was also investigated. Experiments were performed in a linear cascade with a exit Reynolds number of 2.64×105. The film cooling effectiveness on the blade endwall were measured by the pressure sensitive paint technique. Results indicate that the diffusion slot hole significantly increases the film cooling effectiveness on the blade endwall compared to the fan-shaped hole, especially at high blowing ratio. The maximum relative increment of the cooling effectiveness is over 40%. The layout with the discrete holes arranged lining up with the tangent direction of the blade profile offset curves exhibits a comparable film cooling effectiveness with the layout with the discrete holes arranged according to the cross-flow direction. The film cooling effectiveness on the pressure surface corner is remarkably enhanced by deflecting the hole orientation angle towards the pressure surface. The combination of purge slot and diffusion slot holes supplies a full coverage film cooling for the entire blade endwall at coolant mass flow ratio of the purge slot of 1.5% and blowing ratio of 2.5. In addition, the slot injection leads to a non-negligible influence on the cooling performance of the discrete holes near the separation line.


Sign in / Sign up

Export Citation Format

Share Document