The Nuclear Decommissioner and the Regulation of Low Dose Radiation

Author(s):  
Shankar Menon ◽  
Luis Valencia ◽  
Lucien Teunckens

The management of the large quantities of very low level radioactive material that arise during the decommissioning of the increasing numbers of nuclear power stations reaching the end of their commercially useful lives, has become a major subject of discussion. This has very significant economic implications for the nuclear decommissioner. Much larger quantities — 2–3 orders of magnitude larger — of material, radiologically similar to the candidate material for recycling from the nuclear industry, arise in non-nuclear industries like coal, fertiliser, oil and gas, mining, etc. In such industries, naturally occurring radioactivity is artificially concentrated in products, by-products or waste to form TENORM (Technologically Enhanced Naturally Occurring Radioactive Material). It is only in the last decade that the international community has become aware of the prevalence of TENORM, specially the activity levels and quantities arising in so many non-nuclear industries. The first reaction of international organisations seems to have been to propose different standards for the nuclear and non-nuclear industries, with very stringent release criteria for radioactive material from the regulated nuclear industry and up to thirty to a hundred times more liberal criteria for the release/exemption of TENORM from the as yet unregulated non-nuclear industries. The radiological effects of these TENORM releases have recently been dramatically highlighted by the Marina II study, which showed that over 90% of the total exposures of the European population from discharges into the North European marine waters are from radioactive discharges from non-nuclear industries. The results of an international project to validate, by actual measurement, dose calculation codes RESRAD-RECYCLE (USA) and CERISE (France) for recycling, have indicated an overestimation of doses by the codes by an order of magnitude. For the nuclear decommissioner and other producers of large volumes of slightly radioactively contaminated material, clearance levels determined on the basis of such a degree of conservatism in calculations can lead to huge volumes of material unnecessarily being condemned to burial as radioactive waste. Earlier estimates of the quantitative risk levels of exposure to ionising radiation have almost exclusively been based on doses taken by exposed populations of Hiroshima and Nagasaki (ICRP 60). The populations studied have been exposed to over 200 mSv at a dose rate of 6 Sv/s. The effects of such high dose/dose-rate exposure are being used as the basis for risk judgment at doses/dose-rates lower by a factor 1012–1015. The validity of such an extrapolation in risk judgement is an area of prime interest for discussion. In this connection, an interesting development, for both the nuclear and non-nuclear industries, is the increased scientific scrutiny that the populations of naturally high background dose level areas of the world are being subject to. Preliminary biological studies have indicated that the inhabitants of such areas, exposed to many times the permitted occupational doses for nuclear workers, have not shown any differences in cancer mortality, life expectancy, chromosome aberrations or immune function, in comparison with those living in normal background areas. The paper discusses these and other strategic issues regarding the management of redundant low radiation material from both the nuclear and non-nuclear industries, underlining the need for consistency in regulatory treatment.

2014 ◽  
Vol 27 ◽  
pp. 1460136
Author(s):  
LEWIS CARROLL

We are developing a new dose calibrator for nuclear pharmacies that can measure radioactivity in a vial or syringe without handling it directly or removing it from its transport shield “pig”. The calibrator's detector comprises twin opposing scintillating crystals coupled to Si photodiodes and current-amplifying trans-resistance amplifiers. Such a scheme is inherently linear with respect to dose rate over a wide range of radiation intensities, but accuracy at low activity levels may be impaired, beyond the effects of meager photon statistics, by baseline fluctuation and drift inevitably present in high-gain, current-mode photodiode amplifiers. The work described here is motivated by our desire to enhance accuracy at low excitations while maintaining linearity at high excitations. Thus, we are also evaluating a novel “pulse-mode” analog signal processing scheme that employs a linear threshold discriminator to virtually eliminate baseline fluctuation and drift. We will show the results of a side-by-side comparison of current-mode versus pulse-mode signal processing schemes, including perturbing factors affecting linearity and accuracy at very low and very high excitations. Bench testing over a wide range of excitations is done using a Poisson random pulse generator plus an LED light source to simulate excitations up to ∼106 detected counts per second without the need to handle and store large amounts of radioactive material.


Author(s):  
Hallvard Haanes ◽  
Hilde Kristin Skjerdal ◽  
Rosaline Mishra ◽  
Anne Liv Rudjord

Radon and thoron progeny are important contributors to dose from naturally occurring radionuclides, especially in high background areas and with naturally occurring radioactive material (NORM) legacy sites. Due to the short half-life of thoron, measurements of thoron progeny with a longer half-life should be used for risk and dose assessment. Deposition-based alpha track detectors for such progeny are, however, biased by air movement, especially outdoors where winds may be strong but variable. We used deposition detectors for thoron progeny and radon progeny, as well as alpha track gas detectors for 220Rn and 222Rn, outdoors within the Fen complex in Norway, an area with both elevated levels of naturally occurring radionuclides and NORM legacy sites. Different detector types were used and showed different results. We measured airflow along deposition detectors during deployment to assess wind bias and used statistical models to attain location-specific sheltering factors. These models assess how explanatory terms like point measurements with anemometer, predicted airflow along detectors, and levels of 220Rn and 222Rn explained variation in deposition detector measurements of TnP and RnP. For all the detector types, unrealistically, high equilibrium values (F) were found between progenitor noble gas and progeny before correcting for wind bias. Results suggest a magnitude of wind bias on TnP deposition detectors being a fraction of 0.74–0.96 (mean: 0.87) of the total measurement.


1994 ◽  
Author(s):  
J.L.M. Venselaar ◽  
A.H.L. Aalbers ◽  
W.F.M. Brouwer ◽  
H. Meertens ◽  
J.J. Petersen ◽  
...  

2018 ◽  
Vol 64 (1) ◽  
pp. 79-83
Author(s):  
Vladimir Solodkiy ◽  
Andrey Pavlov ◽  
Aleksey Tsybulskiy ◽  
Anton Ivashin

Introduction. One of the main problems of modem on-courology is treatment for prostate cancer of intermediate and high risk of progression. Modern radiotherapy in this category of patients has an advantage over surgical methods of treatment. One way to improve the effectiveness of radiotherapy is to escalate the dose in the prostate gland. For this purpose a combination of brachytherapy and remote radiotherapy is used. This combination allows increasing the dose of radiation, thereby providing better local control, reducing complications from neighboring organs. Purpose of the study. To conduct a comparative analysis of efficacy and safety of radical treatment of patients with prostate cancer at medium and high risk of progression using a combination of high and low dose rate brachytherapy with external beam radiotherapy. Materials and methods. 107 patients with prostate cancer of the group of medium and high risk of progression combined treatment (brachytherapy with external beam radiotherapy) was conducted. 53 patients underwent combined treatment (HDR-brachytherapy and external beam radiotherapy). 54 patients underwent combined treatment (LDR-brachytherapy and external beam radiotherapy). The observation period was 5 years. Conclusion. In a comparative analysis in groups of combined radiotherapy with the use of high-dose and low-dose-rate brachytherapy, the same effectiveness of immediate and long-term results of treatment was demonstrated. A significant reduction in early and late toxic reactions in patients with high-power brachytherapy has been demonstrated.