Heat Transfer Performance for Helium Gas Flowing in a Minichannel With Different Inner Diameters

2021 ◽  
Author(s):  
Feng Xu ◽  
Qiusheng Liu ◽  
Makoto Shibahara

Abstract The high heat load on the first wall of the helium cooled blanket is removed by tube flow of helium gas. Heat transfer augmentation is considered to be acquired by downsizing of channels. Therefore, this paper experimentally studied the influence of inner diameter on the heat transfer performance of helium gas flowing in a minichannel. The helium gas flowed in the small platinum tubes with the inner diameters of 0.8 mm and 1.8 mm, respectively. The heat generation rate of the tube was controlled by a heat input subsystem and raised with an exponential equation. The surface temperature and heat flux of the tubes were obtained under a wide range of e-folding time at different flow velocities. The heat transfer coefficients of different inner diameter tubes were compared at the same conditions. The heat transfer performance of the 0.8 mm-diameter tube was compared with a classical correlation. The experimental results showed that the heat transfer performance in the minichannel is better than a conventional large-diameter tube. The heat transfer coefficients of the 0.8 mm-diameter tube were higher than those of the 1.8 mm-diameter tube. The heat transfer process was enhanced with reducing the inner diameter of the minichannel. The heat transfer process was divided into two parts including transient and quasi-steady-state regions.

Energies ◽  
2018 ◽  
Vol 12 (1) ◽  
pp. 11
Author(s):  
Yanfei Liu ◽  
Xiaotian Han ◽  
Chaoqun Shen ◽  
Feng Yao ◽  
Mengchen Zhang

A vapor chamber can meet the cooling requirements of high heat flux electronic equipment. In this paper, based on a proposed vapor chamber with a side window, a vapor chamber experimental system was designed to visually study its evaporation and condensation heat transfer performance. Using infrared thermal imaging technology, the temperature distribution and the vapor–liquid two-phase interface evolution inside the cavity were experimentally observed. Furthermore, the evaporation and condensation heat transfer coefficients were obtained according to the measured temperature of the liquid near the evaporator surface and the vapor near the condenser surface. The effects of heat load and filling rate on the thermal resistance and the evaporation and condensation heat transfer coefficients are analyzed and discussed. The results indicate that the liquid filling rate that maximized the evaporation heat transfer coefficient was different from the liquid filling rate that maximized the condensation heat transfer coefficient. The vapor chamber showed good heat transfer performance with a liquid filling rate of 33%. According to the infrared thermal images, it was observed that the evaporation/boiling heat transfer could be strengthened by the interference of easily broken bubbles and boiling liquid. When the heat input increased, the uniformity of temperature distribution was improved due to the intensified heat transfer on the evaporator surface.


Energies ◽  
2019 ◽  
Vol 12 (3) ◽  
pp. 414 ◽  
Author(s):  
Shicheng Wang ◽  
Chenyi Xu ◽  
Wei Liu ◽  
Zhichun Liu

Packed beds are widely used in industries and it is of great significance to enhance the heat transfer between gas and solid states inside the bed. In this paper, numerical simulation method is adopted to investigate the heat transfer principle in the bed at particle scale, and to develop the direct enhanced heat transfer methods in packed beds. The gas is treated as continuous phase and solved by Computational Fluid Dynamics (CFD), while the particles are treated as discrete phase and solved by the Discrete Element Method (DEM); taking entransy dissipation to evaluate the heat transfer process. Considering the overall performance and entransy dissipation, the results show that, compared with the uniform particle size distribution, radial distribution of multiparticle size can effectively improve the heat transfer performance because it optimizes the velocity and temperature field, reduces the equivalent thermal resistance of convection heat transfer process, and the temperature of outlet gas increases significantly, which indicates the heat quality of the gas has been greatly improved. The increase in distribution thickness obviously enhances heat transfer performance without reducing the equivalent thermal resistance in the bed. The result is of great importance for guiding practical engineering applications.


2015 ◽  
Vol 1779 ◽  
pp. 39-44 ◽  
Author(s):  
Jan Mary Baloyo ◽  
Yuyuan Zhao

ABSTRACTThe heat transfer coefficients of homogeneous and hybrid micro-porous copper foams, produced by the Lost Carbonate Sintering (LCS) process, were measured under one-dimensional forced convection conditions using water coolant. In general, increasing the water flow rate led to an increase in the heat transfer coefficients. For homogeneous samples, the optimum heat transfer performance was observed for samples with 60% porosity. Different trends in the heat transfer coefficients were found in samples with hybrid structures. Firstly, for horizontal bilayer structures, placing the high porosity layer by the heater gave a higher heat transfer coefficient than the other way round. Secondly, for integrated vertical bilayer structures, having the high porosity layer by the water inlet gave a better heat transfer performance. Lastly, for segmented vertical bilayer samples, having the low porosity layer by the water inlet offered the greatest heat transfer coefficient overall, which is five times higher than its homogeneous counterpart.


Author(s):  
Feng Xu ◽  
Qiusheng Liu ◽  
Satoshi Kawaguchi ◽  
Makoto Shibahara

Abstract The blanket modules of first wall need bear tremendous heat flux due to the very high temperature of plasma in the nuclear fusion reactor. Therefore, it is significant to clarify the knowledge of transient heat transfer process for helium gas flowing in the tubes installed in the blanket modules. In this research, the transient heat transfer process of turbulent forced convection for helium gas flowing in a horizontal minichannel was experimentally investigated. The test tube made of platinum with the inner diameter of 1.8 mm, the wall thickness of 0.1 mm and the effective length of 90 mm was heated by a direct current from power source. The heat generation rate of the test tube, Q̇, was raised with an exponential function, Q̇ = Q0 exp(t/τ), where Q0 is the initial heat generation rate, t is time, and τ is e-folding time of heat generation rate. The heat generation rates of the test tube were controlled and measured by a heat input control system. The flow rates were adjusted by the bypass of gas loop and measured by the turbine flow meter. The experiment was conducted under the e-folding time of heat generation rate ranged from 40 ms to 15 s. Based on experimental data, it is obvious that the heat flux and temperature difference between surface temperature of test tube and bulk temperature of helium gas increased with the exponentially increasing of heat generation rate. At the same flow velocity, the heat transfer coefficients approached constant values when the e-folding time is longer than about 1 s (quasi-steady state), but increased with a decrease of e-folding time when the e-folding time is smaller than about 1 s (transient state). The heat transfer coefficients increased with the increase in flow velocities but showed less dependent on flow velocities at shorter e-folding time. Furthermore, the Nusselt number under quasi-steady and transient condition was affected by the Reynolds number and the Fourier number.


2018 ◽  
Vol 240 ◽  
pp. 05012
Author(s):  
Piotr Kopeć ◽  
Beata Niezgoda-Żelasko

This paper analyses the mixed convection process in a fanless evaporator of an air heat pump. The text of the paper shows the authors’ experimental studies results of the temperature distribution and the local values of heat transfer coefficients on the outer surface of vertical tubes with longitudinal fins for the case of mixed convection and fins of a specific shape of their cross-section (prismatic, wavy fins). The experimental studies include the air velocities wa=2,3 m/s and the temperature differences between air and the refrigerant inside the heat exchanger tubes which is ΔT=24-40K. The results obtained were used for verification of CFD modeling of the heat transfer process for the discussed case of heat transfer and the geometry of the finned surface. The numerical analysis was performed for: the temperature distribution along the fin height, the tube perimeter and height, the distribution of local heat transfer coefficients on the finned tube perimeter and along its height. The simulated calculations were used to verify the method of determination of fin efficiency.


Author(s):  
Claire M. Kunkle ◽  
Jordan P. Mizerak ◽  
Van P. Carey

The development of hydrophilic surface coatings for enhanced wetting characteristics has led to improvement in heat transfer metrics like impinging droplet vaporization time and the heat transfer coefficient. Hydrothermal synthesis, a method of developing hydrophilic surfaces, has been previously shown to produce high performing heat transfer surfaces on copper substrates [1]. Our study applied this production method to aluminum substrates, which have the advantage of being cheaper, lighter, and a more widely used for heat sinks than copper. Previous experiments have shown that water droplets on ZnO nanostructure coated surfaces, at low superheats, evaporate via thin film evaporation rather than nucleate boiling. This leads to heat transfer coefficients as much as three times higher than nucleate boiling models for the same superheat. Our nanocoated aluminum surfaces exhibit superhydrophilicity with an average droplet liquid film thickness of 20–30 microns, which can produce heat transfer coefficients of over 25 kW/m2K. This study discusses characterization of ZnO nanostructured aluminum surfaces to better understand the related mechanisms which lead to such high heat transfer performance. All ZnO nanostructured aluminum surfaces produced for this study exhibited superhydrophilicity, with sessile droplet contact angles of less than 5 degrees. The challenge of achieving accuracy for such low contact angles led to the development of a new wetting metric related to the droplet’s wetted area on a surface rather than the contact angle. This new metric is predicated on the the fact that heat transfer performance is directly related to this wetted area, thickens, and shape of the expanding droplet footprint. Shape irregularity of droplets on these superhydrophilic surfaces is discussed in this study, where there appears to be advantages to irregular spreading compared with surfaces that produce symmetric radial spreading. One form of irregular spreading consists of liquid droplets spreading out both on top of the surface and within the microstructure of the surface coating. The liquid within the microstructure forms films less than 5 microns thick, making local heat transfer coefficients of greater than 100 kW/m2K possible. SEM microscope imaging provided additional insight to the underlying mechanisms which cause these surfaces to produce such exceptional spreading as well as irregular spreading, resulting in very good heat transfer performance. Experimental work was coupled with computational analysis to model the contact line of the droplet footprint. Image processing of experimental photos helps to analyze spreading characteristics, which can be directly related to heat transfer due to film thickness at various points during spreading. Approaches used to characterize these superhydrophilic surfaces advance understanding of the connections between nanoscale structural elements and macroscale performance characteristics in heat transfer. This understanding can reveal key insights for developing even better high performance surfaces for a broad range of applications.


Author(s):  
Eric A. Browne ◽  
Gregory J. Michna ◽  
Michael K. Jensen ◽  
Yoav Peles

The heat transfer performance of two microjet arrays using degassed deionized water was investigated. The in-line jet arrays had a spacing of 250 μm, a standoff of 200 μm, and diameters of 54 and 112 μm. Average heat transfer coefficients were obtained for 150 < Red < 3300 and ranged from 80,000 to 414,000 W/m2-K. A heat flux of 1,110 W/cm2 was attained with 23 °C water and a surface temperature of 50 °C.


2010 ◽  
Vol 132 (4) ◽  
Author(s):  
Eric A. Browne ◽  
Gregory J. Michna ◽  
Michael K. Jensen ◽  
Yoav Peles

The heat transfer performance of two microjet arrays was investigated using degassed deionized water and air. The inline jet arrays had diameters of 54 μm and 112 μm, a spacing of 250 μm, a standoff of 200 μm (S/d=2.2 and 4.6, H/d=1.8 and 3.7), and jet-to-heater area ratios from 0.036 to 0.16. Average heat transfer coefficients with deionized water were obtained for 150≤Red≤3300 and ranged from 80,000 W/m2 K to 414,000 W/m2 K. A heat flux of 1110 W/cm2 was attained with 23°C inlet water and an average surface temperature of 50°C. The Reynolds number range for the same arrays with air was 300≤Red≤4900 with average heat transfer coefficients of 2500 W/m2 K to 15,000 W/m2 K. The effect of the Mach number on the area-averaged Nusselt number was found to be negligible. The data were compared with available correlations for submerged jet array heat transfer.


1990 ◽  
Vol 112 (4) ◽  
pp. 287-292 ◽  
Author(s):  
P. F. Monaghan ◽  
D. P. Finn ◽  
P. H. Oosthuizen

This paper deals with measurement of heat transfer performance of wind convectors, an alternative air source evaporator system for heat pumps. An automatically controlled and monitored outdoor wind convector test facility that is capable of measuring heat transfer rates and overall heat-transfer coefficients to within ± 5 percent measurement uncertainty for up to three wind convectors has been designed, built, and tested. Data on air temperature and humidity, solar radiation, and wind speed and direction are simultaneously collected. The choice of measurement technique for each variable and an error analysis for each sensor is discussed. Typical graphical test results are presented.


2013 ◽  
Vol 135 (6) ◽  
Author(s):  
Satish G. Kandlikar ◽  
Theodore Widger ◽  
Ankit Kalani ◽  
Valentina Mejia

Flow boiling in microchannels has been extensively studied in the past decade. Instabilities, low critical heat flux (CHF) values, and low heat transfer coefficients have been identified as the major shortcomings preventing its implementation in practical high heat flux removal systems. A novel open microchannel design with uniform and tapered manifolds (OMM) is presented to provide stable and highly enhanced heat transfer performance. The effects of the gap height and flow rate on the heat transfer performance have been experimentally studied with water. The critical heat fluxes (CHFs) and heat transfer coefficients obtained with the OMM are significantly higher than the values reported by previous researchers for flow boiling with water in microchannels. A record heat flux of 506 W/cm2 with a wall superheat of 26.2 °C was obtained for a gap size of 0.127 mm. The CHF was not reached due to heater power limitation in the current design. A maximum effective heat transfer coefficient of 290,000 W/m2 °C was obtained at an intermediate heat flux of 319 W/cm2 with a gap of 0.254 mm at 225 mL/min. The flow boiling heat transfer was found to be insensitive to flow rates between 40–333 mL/min and gap sizes between 0.127–1.016 mm, indicating the dominance of nucleate boiling. The OMM geometry is promising to provide exceptional performance that is particularly attractive in meeting the challenges of high heat flux removal in electronics cooling applications.


Sign in / Sign up

Export Citation Format

Share Document