Pressure Drop Fluctuation and Flow Regime Identification for Air-Water Two-Phase Flow

2000 ◽  
Author(s):  
Bofeng Bai ◽  
Tiejun Wu ◽  
Liejin Guo ◽  
Xuejun Chen

Abstract The fluctuating pressure drop for air-water two-phase flow was measured in the vertical upward section of U-type tube with 0.05m I.D. The feature of the fluctuations was extracted by means of statistical and chaotic theories. The influence of liquid superficial velocity on the features was also investigated. The results showed that the mean, root mean square, fractal dimension of pressure drop fluctuations is function of flow regimes. The fractal dimension can be larger than 1.5 in annular flow with great liquid superficial velocity which is reported for the first time. Furthermore, the present paper provided a feasible solution, which the gas-liquid two-phase flow regimes can be recognized automatically and objectively on basis of the combination of the Counter Propagation Network (CPN) and the FFT coefficients of the differential pressure fluctuations. The recognition possibility is determined by the clustering results of the Kohonen layer in the CPN. With the presented test cases, the possibility can be greater than 90 percent for different liquid phase velocity.

Author(s):  
Christian Weinmu¨ller ◽  
Dimos Poulikakos

Microfluidics has experienced a significant increase in research activities in recent years with a wide range of applications emerging, such as micro heat exchangers, energy conversion devices, microreactors, lab-on-chip devices and micro total chemical analysis systems (μTAS). Efforts to enhance or extend the performance of single phase microfluidic devices are met by two-phase flow systems [1, 2]. Essential for the design and control of microfluidic systems is the understanding of the fluid/hydrodynamic behavior, especially pressure drop correlations. These are well established for single phase flow, however, analytical correlations for two-phase flow only reflect experimentally obtained values within an accuracy of ± 50% [3, 4]. The present study illustrates the effect of two-phase flow regimes on the pressure drop. Experimental measurement data is put into relation of calculated values based on established correlations of Lockhart-Martinelli with Chisholm modifications for macroscopic flows [5, 6] and Mishima-Hibiki modifications for microscale flows [7]. Further, the experimental pressure drop data is superimposed onto two-phase flow maps to identify apparent correlations of pressure drop abnormalities and flow regimes. The experiments were conducted in a square microchannel with a width of 200 μm. Optical access is guaranteed by an anodically bonded glass plate on a MEMS fabricated silicon chip. Superficial velocities range from 0.01 m/s to 1 m/s for the gas flow and from 0.0001 m/s to 1 m/s for the liquid flow with water as liquid feed and CO2 as gas. The analysis of the flow regimes was performed by imaging the distinct flow regimes by laser induced fluorescence microscopy, employing Rhodamine B as the photosensitive dye. The pressure drop was synchronically recorded with a 200 mbar, 2.5 bar and 25 bar differential pressure transmitter and the data was exported via a LabView based software environment, see Figure 1. Figure 2 illustrates the experimentally obtained pressure drop in comparison to the calculated values based on the Lockhard-Martinelli correlation with the Chisholm modification and the Mishima-Hibiki modification. For both cases the predications underestimate the two-phase pressure drop by more than 50%. Nevertheless, the regression of the experimental data has an offset of linear nature. Two-phase flow is assigned to flow regime maps of bubbly, wedging, slug or annular flow defined by superficial gas and liquid velocities. In Figure 3 the pressure drop is plotted as a surface over the corresponding flow regime map. Transition lines indicate a change of flow regimes enclosing an area of an anticline in the pressure data. In the direct comparison between the calculated and the measured values, the two surfaces show a distinct deviation. Especially, the anticline of the experimental data is not explained by the analytical correlations. Figure 4 depicts the findings of Figure 3 at a constant superficial velocity of 0.0232 m/s. The dominant influence of the flow regimes on the pressure drop becomes apparent, especially in the wedging flow regime. The evident deviation of two-phase flow correlations for the pressure drop is based on omitting the influence of the flow regimes. In conclusion, the study reveals a strong divergence of pressure drop measurements in microscale two-phase flow from established correlations of Lockhart-Martinelli and recognized modifications. In reference to [8, 9], an analytical model incorporating the flow regimes and, hence, predicting the precise pressure drop would be of great benefit for hydrodynamic considerations in microfluidics.


Author(s):  
D. Brutin ◽  
L. Tadrist

The present paper deals with two-phase flow pressure drop modeling. This is based on solving the mass, momentum and energy balance equations in steady state conditions. In the two-phase zone, the liquid-vapor is assumed to be a homogeneous fluid. The calculated pressure drop variation is found to be similar to the experimental one when the two–phase flow is steady. In the unsteady state conditions characterized by high amplitude of the pressure fluctuations, the computed pressure drop is found to be different from the experimental mean pressure drop. This difference is all the higher as the pressure fluctuation is high.


2012 ◽  
Vol 33 (2) ◽  
pp. 47-65
Author(s):  
Amr Mohamed Elazhary ◽  
Hassan M. Soliman

Abstract An experimental study was conducted in order to investigate two-phase flow regimes and fully developed pressure drop in a mini-size, horizontal rectangular channel. The test section was machined in the form of an impacting tee junction in an acrylic block (in order to facilitate visualization) with a rectangular cross-section of 1.87-mm height on 20-mm width on the inlet and outlet sides. Pressure drop measurement and flow regime identification were performed on all three sides of the junction. Air-water mixtures at 200 kPa (abs) and room temperature were used as the test fluids. Four flow regimes were identified visually: bubbly, plug, churn, and annular over the ranges of gas and liquid superficial velocities of 0.04 ≤ JG ≤ 10 m/s and 0.02 ≤ JL ≤ 0.7 m/s, respectively, and a flow regime map was developed. Accuracy of the pressure-measurement technique was validated with single-phase, laminar and turbulent, fully developed data. Two-phase experiments were conducted for eight different inlet conditions and various mass splits at the junction. Comparisons were conducted between the present data and former correlations for the fully developed two-phase pressure drop in rectangular channels with similar sizes. Wide deviations were found among these correlations, and the correlations that agreed best with the present data were identified.


2017 ◽  
Vol 139 (3) ◽  
Author(s):  
Ammar Zeghloul ◽  
Abdelwahid Azzi ◽  
Faiza Saidj ◽  
Abdelkader Messilem ◽  
Barry James Azzopardi

Pressure drop has been measured for upward single- and two-phase gas–liquid flow across an orifice in a vertical pipe. A conductance probe provided average void fraction upstream of the orifice. Six orifices with different apertures/thickness were mounted in turn in a 34 mm diameter transparent acrylic resin pipe. Gas and liquid superficial velocities of 0–4 m/s and 0.3–0.91 m/s, respectively, were studied. For single-phase flow, pressure drop, expressed as an Euler number, was seen to be independent of Reynolds number in turbulent region. The Euler number increased with decreasing the open area ratio/orifice thickness and increasing velocity. The pressure drop was well predicted by the correlation of Idel'chik et al. (1994, Handbook of Hydraulic Resistances, 3rd ed., CRC Press, Boca, Raton, FL.), which uses a form of Euler number. The corresponding two-phase flow pressure drop depends on the flow pattern. Decreasing open area ratio/orifice thickness increased the pressure drop. For a given liquid superficial velocity, the pressure drop increases with gas superficial velocity except for low open area ratio where this increase is followed by a decrease beyond a critical superficial gas velocity for the high liquid superficial velocities. Relevant correlations were assessed using the present data via a systematic statistical approach. The two-phase multiplier equations of Morris (1985, “Two-Phase Pressure Drop Across Valves and Orifice Plates,” European Two Phase Flow Group Meeting, Marchwood Engineering Laboratories, Southampton, UK.) and Simpson et al. (1983, “Two-Phase Flow Through Gate Valves and Orifice Plates,” International Conference on Physical Modelling of Multiphase Flow, Coventry, UK.) are the most reliable ones.


2004 ◽  
Vol 126 (1) ◽  
pp. 107-118 ◽  
Author(s):  
J. L. Pawloski ◽  
C. Y. Ching ◽  
M. Shoukri

The void fractions, flow regimes, and pressure drop of air-oil two-phase flow in a half-inch diameter pipe over a wide range of test conditions have been investigated. The flow regimes were identified with the aid of a 1000 frames per second high-speed camera. A capacitance sensor for instantaneous void fraction measurements was developed. The mean and probability density function of the instantaneous void fraction signal can be used to effectively identify the different flow regimes. The current flow regime data show significant differences in the transitional boundaries of the existing flow regime maps. Property correction factors for the flow regime maps are recommended. The pressure drop measurements were compared to the predictions from four existing two-phase flow pressure drop models. Though some of the models performed better for certain flow regimes, none of the models were found to give accurate results over the entire range of flow regimes.


Author(s):  
Shuichiro Miwa ◽  
Yang Liu ◽  
Takashi Hibiki ◽  
Mamoru Ishii ◽  
Yoshiyuki Kondo ◽  
...  

In this study, fluctuating force induced by both upward and horizontal gas-liquid two-phase flow on 90 degree pipe bend at atmospheric condition was investigated. First, the database comprised of dynamic force signals and two-phase flow parameters such as volumetric fluxes, area averaged void fraction and pressure fluctuations covering entire two-phase flow regimes was developed for both flow orientations. Then, study was conducted to develop a model which is capable of predicting the force fluctuation frequency and magnitudes particularly for the slug flow regime. The model was fundamentally developed from the local instantaneous two-fluid model which was applied to the control volume around the elbow test section. Main contribution of the force fluctuation of two-phase flow is from the momentum and pressure fluctuations for most of the flow regimes. For slug flow regime, however, water-hammer like impact was produced by the collision of liquid slug against the structure surface. In order to consider that effect, the liquid slug impact force model was developed. The model utilizes two-group interfacial area concentration correlation to treat the flow regime transition without an abrupt discontinuity. It was found that the newly developed model is capable of predicting two-phase flow induced force fluctuation and dominant frequency range with satisfactory accuracy for flow regimes up to churn-turbulent.


Sign in / Sign up

Export Citation Format

Share Document