scholarly journals Diagnosis of endometriotic lesions by sonovaginography with ultrasound gel

2016 ◽  
Vol 18 (4) ◽  
pp. 469 ◽  
Author(s):  
Elvira Brătilă ◽  
Diana Elena Comandaşu ◽  
Ciprian Coroleucă ◽  
Monica Mihaela Cîrstoiu ◽  
Costin Berceanu ◽  
...  

Aims: The aim of the study was to evaluate the diagnostic ability of sonovaginography (SVG) with ultrasound gel in patients with endometriosis. Material and methods: We conducted a multicentre prospective study, which included 193 patients with symptoms highly suggestive for endometriosis. All patients were investigated by transvaginal sonography and SVG with gel and afterwards underwent laparoscopic surgery. For each category of endometriotic lesions investigated, we calculated and compared the sensitivity, specificity,  positive predictive value and negative predictive value of the imagisticinvestigations used. Results: In the case of endometriotic lesions of the uterosacral ligaments, SVG with gel had a sensitivity of 78.5% and a specificity of 96% (p=ns). The lesions of the vagina and rectovaginal septum were diagnosed with a sensitivity of 79%, respectively 94% (p=ns), obtaining a specificity of 99%, respectively of 97% (p=0.007). The lesions of the Douglas pouch were identified with a sensitivity of 81% (p=0.015), and those of the rectosigmoid with a 94% sensitivity (p=0.010). We obtained lower sensitivity (67%) in detecting the lesions of the urinary bladder (p=ns). Conclusions: SGV with ultrasound gel represents a useful investigation tool for the evaluation of endometriotic lesions in the posterior pelvic compartment.

2014 ◽  
Vol 39 (2) ◽  
pp. 80-85
Author(s):  
MS Showkat ◽  
S Nabi ◽  
L Khondker ◽  
B Bhowmik ◽  
SN Tushar ◽  
...  

Transvagival sonography is superior to transabdominal sonography in most cases of pelvic pathology. Objective of this study is to evaluate the clinical usefulness of transvaginal ultrasonography (TVS) in pre, peri and post menopausal women suspected to have endometrial carcinoma. This cross sectional study was done with 40 patients who are clinically suspected having thickened endometrium. The study was carried out January 2007 to November 2008 for a period of two years. The patients having endometrial carcinoma diagnosed by TVS was correlated with histopathological diagnosis following collection of the report from the respective cases. Of total 40 cases, 2(5.0%) cases were endometrial carcinoma and 38(95.0%) were negative for endometrial carcinoma respectively in TVS findings. On the other hand 3(7.5%) cases were endometrial carcinoma and 37 (92.5%) cases were negative for endometrial carcinoma in histopathological findings. The validity of TVS in diagnosis of endometrial carcinoma were studied by calculating sensitivity, specificity, accuracy, positive predictive value and negative predictive value, which were 67 percent, 100 percent, 98 percent, 100 percent and 97 percent respectively. As the TVS findings of the present study correlated well with the histopathology findings and the validity test values were higher than observed by others, it can be concluded that TVS is sensitive and accurate modality in the evaluation of endometrial carcinoma. DOI: http://dx.doi.org/10.3329/bmrcb.v39i2.19647 Bangladesh Med Res Counc Bull 2013; 39: 80-85


2004 ◽  
Vol 14 (1) ◽  
pp. 57-63 ◽  
Author(s):  
M. A. Guven ◽  
T. Bese ◽  
F. Demirkiran

BackgroundThe aim of the study was to compare the accuracy of hydrosonography with that of transvaginal ultrasonography in detection of intracavitary pathologies in patients with history of abnormal uterine bleeding.Study designProspective, randomized, and unblinded study.Material and methodsA total of 197 women (n = 130 premenopausal and n = 67 postmenopausal) aged between 23 and 71 years (mean age 45.7 ± 8.9) presenting with a history of abnormal uterine bleeding were included into the study. Hydrosonography was carried out by experienced gynecologists, on the same setting in an outpatient clinic immediately after the performance of transvaginal sonography. The finally obtained surgical-pathologic findings were compared with the results obtained from transvaginal sonography and hydrosonography. Sensitivity, specificity, positive, and negative predictive values were calculated for each procedure.ResultsThe surgical-pathologic examination confirmed normal physiologic endometrium in 50 (48%) of 104 women who were said to have normal endometrium on transvaginal sonography. Seventy (75%) of 93 women diagnosed of intracavitary pathologies on transvaginal sonography were confirmed by surgical-pathologic findings. The sensitivity, specificity, positive predictive value, and negative predictive value of transvaginal sonography in the detection of intracavitary pathology were 56, 68, 75, and 48%, respectively. Surgical-pathologic results revealed intracavitary pathologies in 23 (30%) of 76 women who were said to have normal endometrium on hydrosonography. Among 121 women diagnosed of intracavitary pathologies on hydrosonography, 101 (81%) women were confirmed after histological evaluation of the surgical specimens. The sensitivity, specificity, positive predictive value, and negative predictive value of hydrosonography in the detection of intracavitary pathology were 81, 73, 83, and 70%, respectively. Sensitivity and negative predictive value were significantly higher with hydrosonography. There were five cases of endometrial malignancy in which one of the case of malignancy was on polyp and two cases of endometrial hyperplasia with atypia which were not stated on sonographic results.ConclusionHydrosonography is more accurate than transvaginal ultrasography in the detection of intracavitary pathologies in women with abnormal uterine bleeding.


2018 ◽  
Vol 2018 ◽  
pp. 1-8 ◽  
Author(s):  
Tanoj Bahadur Singh ◽  
Liwu Zhang ◽  
Xiaoting Huo ◽  
Guoping Liu ◽  
Hongyan Ni ◽  
...  

Objective. To evaluate the diagnostic ability of rs-DWI to detect subtle acute infarction lesion in the different regions of the brain in comparison to routine DWI and the comparison between different b-values. Method. 35 acute brain infarction patients were included. The subtle acute infarction lesions in ss-DWI and rs-DWI sequence were evaluated in 9 anatomical regions of the brain, and the ss-EPI DWI was also acquired with different b-values of 0, 1000, 2000, and 3000s/mm2. The McNemar test was performed for comparing the diagnostic ability of ss-DWI and rs-DWI and different b-values. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for the whole brain and in each anatomical region were calculated. Result. A total of 406 subtle acute infarction lesions were confirmed. The ss-DWI detected 338 subtle lesions, out of which 318 were true positive and 20 were false positive lesions. The rs-DWI detected 386 subtle lesions, out of which 385 were true positive lesions and 1 was true negative lesion. Sensitivity, specificity, positive predictive value, and negative predictive value in rs-DWI were better than ss-DWI in all anatomical regions of the brain. In the comparison of different b-values, b2000 was found better among b1000, b2000, and b3000. Conclusion. The rs-DWI offers a useful alternative to routine DWI for detecting the subtle acute infarctions, especially in the regions that are susceptible to distortion as in frontal cortex. In addition, high b-value can also provide benefit by increasing diffusion weighting but further raising can deteriorate image quality as SNR is decreased.


Author(s):  
Robert Yeung ◽  
Tabassum Ahmad ◽  
Richard I. Aviv ◽  
Lyne Noel de Tilly ◽  
Allan J. Fox ◽  
...  

Background and Purpose:To compare the efficacy of computed tomographic angiography (CTA) to that of digital subtraction angiography (DSA) in the detection of secondary causes of intracerebral hemorrhage (ICH).Methods:Between January 2001 and February 2007 there were 286 patients that had both CTA and DSA for intracranial hemorrhage of all types. Those with primarily subarachnoid hemorrhage or recent trauma were excluded. Fifty-five patients formed the study cohort. Three reviewers independently analyzed the CTAs in a blinded protocol and classified them based on presence or absence of a secondary etiology. Results were compared with the reference standard DSA and kappa values determined for interobserver variability.Results:The overall sensitivity, specificity, positive predictive value, negative predictive value and accuracy of CTA were 89%, 92%, 91%, 91% and 91%, respectively. Kappa value for interobserver agreement ranged from 0.78 to 0.89. Two of four dural arteriovenous fistulas (dAVF) were missed on CTA by all three reviewers.Conclusion:CTA is nearly as effective as DSA at determining the cause of secondary intracerebral hemorrhage, but with a lower sensitivity for dAVFs. This supports the use of CTA as the first screening test in patients presenting with spontaneous ICH.


2018 ◽  
Vol 142 (7) ◽  
pp. 863-870 ◽  
Author(s):  
Ezgi Hacihasanoglu ◽  
Bahar Memis ◽  
Burcin Pehlivanoglu ◽  
Vaidehi Avadhani ◽  
Alexa A. Freedman, ◽  
...  

Context.— Literature on factors impacting bile duct brushings (BDBs) performance characteristics remain limited. Objective.— To capture the current state of daily practice with BDB sign-out. Design.— Two hundred fifty-three of 444 BDBs signed out by more than 7 cytopathologists, with histopathologic and/or clinical follow-up of at least 18 months, were examined. Results.— One hundred thirty-five of 253 BDBs (53%) had histologically confirmed malignancies, 22 (9%) had cancer-related deaths, and 96 (38%) were benign. Cytologic diagnoses in the 444 BDBs were nondiagnostic (11 [2.5%]), negative (284 [64%]), atypical (62 [13.9%]), suspicious (34 [7.7%]), and malignant (53 [11.9%]). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of malignancy detection were 35%, 100%, 100%, 58%, and 66%, respectively. When atypical, suspicious, and malignant (ASM) categories were combined, sensitivity increased (58%), specificity and PPV dropped (97%), and accuracy increased (73%). Carcinoma type (bile-duct versus pancreatic-ductal) had no effect on accuracy (P = .60) or diagnostic class (P = .84), nor did time of performance (first 7.5 versus latter 7.5 years, P = .13). Interestingly, ThinPrep + cell block (n = 41) had higher sensitivity (61%) and lower specificity (80%) than ThinPrep only (versus 51% and 100%, respectively). Sensitivity and specificity were higher (47% and 100%) in nonstented than stented specimens (59% and 97%). Relative risk of malignancy for “suspicious” (2.30) and “atypical” (2.28) categories was lower but not very different from that of “malignant” category (2.41). Conclusions.— Bile duct brushings had fairly low sensitivity but high specificity and PPV with no false positives. Sensitivity almost doubled and specificity dipped minimally when ASM categories were combined, highlighting the need for better classification criteria for atypical/suspicious cases. Higher specificity, PPV, NPV, and accuracy but lower sensitivity in stented BDBs suggest that they be called malignant only when evidence is overwhelmingly convincing.


2015 ◽  
Vol 2015 ◽  
pp. 1-6 ◽  
Author(s):  
Konjit Getachew ◽  
Tamrat Abebe ◽  
Abebaw Kebede ◽  
Adane Mihret ◽  
Getachew Melkamu

Background. Despite its lower sensitivity, smear microscopy remains the main diagnostic method for pulmonary tuberculosis (PTB) in resource-limited countries as TB culturing methods like LJ (Lowenstein-Jensen) are expensive to use as a routine base. This study aimed to evaluate the performance of LED-FM for the diagnosis of PTB in HIV positive individuals.Methods. Cross-sectional study was conducted in Zewditu Memorial Hospital and Teklehaimanot Health Center HIV/ART clinics in Addis Ababa, Ethiopia. Each sample was stained with ZN and Auramine O staining and examined with bright-field microscope and LED-FM microscope, respectively. LJ culture was used as a reference.Results. Out of 178 study participants, twenty-four (13.5%) patients were confirmed as positive for MTB with LJ culture. The yield of ZN microscopy and LED-FM in direct and concentrated sample was 3.9%, 8.4%, 6.2%, and 8.4%, respectively. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of direct ZN microscopy were 29.2%, 100%, 100%, and 90.1%, respectively, and of LED-FM microscopy in direct sputum sample were 62.5%, 100%, 100%, and 94.5%, respectively.Conclusion. LED-FM has better sensitivity for the diagnosis of PTB in HIV positive individuals as compared to conventional ZN microscopy. LED-FM can be used as an alternative to conventional ZN microscopy.


2022 ◽  
Vol 8 (1) ◽  
pp. 86
Author(s):  
Anders Krifors ◽  
Måns Ullberg ◽  
Markus Castegren ◽  
Johan Petersson ◽  
Ernesto Sparrelid ◽  
...  

The T2Candida magnetic resonance assay is a direct-from-blood pathogen detection assay that delivers a result within 3–5 h, targeting the most clinically relevant Candida species. Between February 2019 and March 2021, the study included consecutive patients aged >18 years admitted to an intensive care unit or surgical high-dependency unit due to gastrointestinal surgery or necrotizing pancreatitis and from whom diagnostic blood cultures were obtained. Blood samples were tested in parallel with T2Candida and 1,3-β-D-glucan. Of 134 evaluable patients, 13 (10%) were classified as having proven intraabdominal candidiasis (IAC) according to the EORTC/MSG criteria. Two of the thirteen patients (15%) had concurrent candidemia. The sensitivity, specificity, positive predictive value, and negative predictive value, respectively, were 46%, 97%, 61%, and 94% for T2Candida and 85%, 83%, 36%, and 98% for 1,3-β-D-glucan. All positive T2Candida results were consistent with the culture results at the species level, except for one case of dual infection. The performance of T2Candida was comparable with that of 1,3-β-D-glucan for candidemic IAC but had a lower sensitivity for non-candidemic IAC (36% vs. 82%). In conclusion, T2Candida may be a valuable complement to 1,3-β-D-glucan in the clinical management of high-risk surgical patients because of its rapid results and ease of use.


2020 ◽  
Vol 14 (2) ◽  
pp. 97-102
Author(s):  
Khalid Rehman `Yousaf ◽  
Shahzad Saeed ◽  
Saman Chaudhry ◽  
Rabia Bashrat ◽  
Abadullah Khalid ◽  
...  

Background: Ovarian torsion diagnosis is a great challenge as delay in diagnosis can cause severe morbidity. Early accurate diagnosis is crucial to preserve ovarian function. Ultrasonography being the primary imaging modality plays a vital role in the evaluation of suspected ovarian torsion by helping surgeons reach the correct diagnosis, thus avoiding unnecessary intervention. This study aims to determine the diagnostic accuracy of isolated and combined sonographic features of ovarian torsion on grey scale and Doppler transvaginal ultrasonography. Patients and methods: From radiology database, from January 2016 till December 2019, sonographic signs of ovarian torsion in 113 women with suspected ovarian torsion on ultrasonography and subsequent surgical diagnosis were evaluated. Ultrasound findings were compared with surgical findings to determine the accuracy, sensitivity, specificity, and positive and negative predictive values of individual and combined ultrasound signs. Results: Diagnostic accuracy of ultrasound for ovarian torsion was 85.8%. Abnormal ovarian Doppler flow was the most accurate individual sonographic sign with accuracy, sensitivity, specificity and positive predictive value of 85.8%, 83.5%, 100% and 100% respectively followed by ovarian enlargement and ovarian edema. Combined ultrasound signs resulted in higher sensitivity and positive predictive values, and lower specificity and negative predictive values for ovarian torsion. Increasing the number of sonographic parameters increased the specificity but decreased sensitivity. High accuracy, sensitivity, positive predictive value, specificity and negative predictive value was seen when combination of three or two sonographic parameters was used as diagnostic criteria. Conclusion: Transvaginal sonography is a convenient, reliable and extremely useful imaging modality for preoperative diagnosis of ovarian torsion with high specificity, sensitivity, positive predictive value and diagnostic accuracy helping treating physicians to take prompt decisions regarding timely surgical intervention. However, due to low negative predictive values, absence of sonographic signs does not rule out ovarian torsion and high index of clinical suspicion remains of utmost importance.


Author(s):  
Nisha Solanki ◽  
Prashant Suryarao ◽  
Aditi Bhatnagar

Background: Postmenopausal bleeding is defined as permanent cessation of menstruation resulting from the loss of ovarian follicular activity. Incidence of abnormal uterine bleeding is 10% to 15% in postmenopausal bleeding. For evaluation of postmenopausal bleeding earlier dilatation and curettage was considered as gold standard which is a blind procedure, transvaginal sonography has improved the accuracy of endometrial morphology. Now the focus has shifted to hysteroscopic guided biopsy which is gold standard for evaluating postmenopausal bleeding it also has benefit of see and treat modality. The objective of this study was to study the significance of hysteroscopy in diagnosis of etiopathological factors of postmenopausal bleeding. To correlate the diagnosis by TVS, hysteroscopy and histopathological diagnosis.Methods: The study was conducted at Dr. D. Y. Patil Medical College and Hospital from June 2016 to September 2018. A total of 30 cases were evaluated. The commencement of the study was followed by approval of the institutional ethical committee.Results: In our study, 83.34% of patients with postmenopausal bleeding where in age group menopause is >55 years. 66.67% are overweight with BMI of 25-29.9. We evaluated the ET <4 mm, 4-12 mm, >12 mm thickness, 53.33% were between 4-12 mm of ET. In our study endometrial hyperplasia shows 30% in hysteroscopy, on HPE shows 33.33%, in atrophic endometrium 20% on HPE is also 20%, polyp shows 6.67% in both hysteroscopy and HPE, sub mucous myoma on both hysteroscopy and HPE shows 3.33% and Ca endometrium shows 3.33% in both hysteroscopy and HPE.Conclusions: Study of total 30 cases were conducted, by using Bettochi Office hysteroscope (2.9 mm). Sensitivity, specificity, positive predictive value and negative predictive value of hysteroscopy was calculated in each group of patients.


2019 ◽  
Vol 36 (1) ◽  
pp. 31-35
Author(s):  
Yevheniia Poliakova ◽  
Nataliia Lutsenko

Background: Transvaginal sonography (TVS) is considered a simple and generally accepted method for detecting uterine anomalies. With TVS, the uterus can be clearly visualized, but so far, the diagnostic accuracy of TVS varies across different studies. This retrospective study was devised to evaluate the accuracy of a sonographic diagnosis of endometrial polyps in a Ukrainian hospital. Methods: This was a single-center retrospective study of woman who underwent TVS and had hysteroscopy or dilation and curettage for endometrial pathology. A cohort of 156 women were included in this yearlong study. A comparative analysis was based on the preoperative diagnosis, according to TVS, compared with the postoperative histopathology results. Results: The overall sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of TVS in diagnosing endometrial polyps were 69%, 51%, 73%, 46%, and 63%, respectively. Conclusion: This retrospective study provided data on the lack of accuracy for a sonographic diagnosis of endometrial polyps. This was based on 26% of women whose diagnosis was not confirmed by histology. A false-negative result occurred for 54% of women who had polyps that were not detected at the preoperative stage. These data raise the question of the feasibility of further invasive procedures based on a single TVS study.


Sign in / Sign up

Export Citation Format

Share Document