Comparison of hydrosonography and transvaginal ultrasonography in the detection of intracavitary pathologies in women with abnormal uterine bleeding

2004 ◽  
Vol 14 (1) ◽  
pp. 57-63 ◽  
Author(s):  
M. A. Guven ◽  
T. Bese ◽  
F. Demirkiran

BackgroundThe aim of the study was to compare the accuracy of hydrosonography with that of transvaginal ultrasonography in detection of intracavitary pathologies in patients with history of abnormal uterine bleeding.Study designProspective, randomized, and unblinded study.Material and methodsA total of 197 women (n = 130 premenopausal and n = 67 postmenopausal) aged between 23 and 71 years (mean age 45.7 ± 8.9) presenting with a history of abnormal uterine bleeding were included into the study. Hydrosonography was carried out by experienced gynecologists, on the same setting in an outpatient clinic immediately after the performance of transvaginal sonography. The finally obtained surgical-pathologic findings were compared with the results obtained from transvaginal sonography and hydrosonography. Sensitivity, specificity, positive, and negative predictive values were calculated for each procedure.ResultsThe surgical-pathologic examination confirmed normal physiologic endometrium in 50 (48%) of 104 women who were said to have normal endometrium on transvaginal sonography. Seventy (75%) of 93 women diagnosed of intracavitary pathologies on transvaginal sonography were confirmed by surgical-pathologic findings. The sensitivity, specificity, positive predictive value, and negative predictive value of transvaginal sonography in the detection of intracavitary pathology were 56, 68, 75, and 48%, respectively. Surgical-pathologic results revealed intracavitary pathologies in 23 (30%) of 76 women who were said to have normal endometrium on hydrosonography. Among 121 women diagnosed of intracavitary pathologies on hydrosonography, 101 (81%) women were confirmed after histological evaluation of the surgical specimens. The sensitivity, specificity, positive predictive value, and negative predictive value of hydrosonography in the detection of intracavitary pathology were 81, 73, 83, and 70%, respectively. Sensitivity and negative predictive value were significantly higher with hydrosonography. There were five cases of endometrial malignancy in which one of the case of malignancy was on polyp and two cases of endometrial hyperplasia with atypia which were not stated on sonographic results.ConclusionHydrosonography is more accurate than transvaginal ultrasography in the detection of intracavitary pathologies in women with abnormal uterine bleeding.

Author(s):  
Kaushik Mahajan ◽  
R. K. Praneshwari Devi ◽  
Ajitkumar Singh ◽  
Dipenty Lairenjam ◽  
Leimapokpam Roshan Singh ◽  
...  

Background: AUB is a common and debilitating condition and it is one of the main gynaecological reasons for hysterectomy. Ultrasonography can be as good as histopathology (HPE) in the diagnosis of abnormal uterine bleeding. Hence, our study was conducted to validate the ultrasonographic findings with HPE findings in diagnosis of AUB.Methods: A hospital based cross-sectional analytical study was conducted among 86 patients with abnormal uterine bleeding in the department of Obstetrics and Gynaecology in collaboration with department of Pathology, RIMS, Imphal from September 2017 to March 2019. The clinical history and socio demographic profile were collected using a pre-designed proforma. General physical examination, pelvic examination and ultrasonagraphy was carried out and the hysterectomy specimens were subjected to histopathological examination.Results: Fibromyoma was diagnosed by ultrasound in 62.8% of the patients and it was the common diagnosis in this study. The sensitivity, specificity, positive predictive value, negative predictive value and kappa statistics of USG for diagnosing leiomyoma was 92.9%, 93.3%, 96.3%, 87.5% and 84.9% respectively. The sensitivity, specificity, positive predictive value, negative predictive value and kappa statistics of USG for diagnosing adenomyosis was 53.8%, 98.6%, 87.5%, 92.3% and 62.3% respectively.Conclusions: The study provides an evidence that ultrasonography has good diagnostic accuracy as histopathology in the diagnosis of fibroid in patients with abnormal uterine bleeding. However, as with all the diagnostic procedures, the utility of ultrasound in the diagnosis of adenomyosis is questionable, since it has a low sensitivity amidst good specificity.


Author(s):  
Priyanka Singh ◽  
Kalpana Kumari ◽  
Shikha Seth ◽  
Vandana Verma ◽  
Vikram Singh

Background: Abnormal uterine bleeding is one of the commonest clinical presentation ac-counts for 33% gynaecological consultations and this proportion rises to 70% in perimenopausal and postmenopausal age group in any gynaecology clinic. The most probable etiology of abnormal uterine bleeding relates to the patients reproductive age. Various diagnostic techniques have been evolved over the periods to determine the etiology of abnormal uterine bleeding in perimenopausal women, but their accuracy has not been compared properly. The aim of study is to evaluate the endometrium by transvaginal ultrasonography and hysteroscopy and its correlation with histopathology in perimenopausal patients with abnormal uterine bleeding.Methods: Total 96 patients in perimenopausal age group, admitted with chief complaints of ab-normal uterine bleeding were included. All patients underwent transvaginal ultrasonography and hysteroscopy, followed by hysteroscopy guided biopsy and histopathological examination. Accuracy, sensitivity, specificity, positive predictive value and negative predictive value were calculated for both methods and compared, considering histopathological diagnosis as gold standard.Results: Mean age of patients was 44.05±3.29. Hysteroscopy has high accuracy, sensitivity, specificity, positive predictive value and negative predictive value than Transvaginal sonography for diagnosis of all endometrial and intrauterine pathologies.Conclusions: Hysteroscopy results are more consistent with the results of histopathology. Hysteroscopy and hysteroscopy guided biopsy has been proven as gold standard for endometrial evaluation of patients with abnormal uterine bleeding. TVS can be used as most cost effective first step investigation in cases of perimenopausal bleeding.


2020 ◽  
Vol 10 (1) ◽  
pp. 1613-1617
Author(s):  
Hari Kishor Shrestha ◽  
Ram Chandra Adhikari ◽  
Khadga Bahadur Shrestha

Background: Transvaginal ultrasonography has increased the reliability of imaging diagnosis of women with endometrial pathologies and this technique has become widely used to evaluate endometrial thickness in women with postmenopausal bleeding. Materials and methods: 359 women presenting with history of at least three months amenorrhea were undergone transvaginal ultrasonography with measurement of endometrial thickness and uterine size. Endometrial biopsies were taken in 69 cases (19.2%) only. Results: The median age of patients was 53 years with the age range of 42 years to 81 years. Abdominal pain was the commonest symptoms followed by backache. 3/69 cases with histopathological diagnoses had normal sized uterus, while 66 cases had bulky (>6.0 cm) uterus. 58/69 cases showed > 5 mm thick endometrium and the endometrium was abnormal in 31/69 cases. The sensitivity, specificity, positive predictive value and negative predictive value of transvaginal ultrasonography to detect abnormal endometrium were 91.2%, 22.9%, 53.4% and 72.7% respectively. The sensitivity, specificity, positive predictive value and negative predictive value of transvaginal ultrasonography to detect endometrial hyperplasia and carcinoma were 100%, 17.5%, 10.3% and 100% respectively. Conclusions: Transvaginal sonographic evaluation of endometrial thickness and uterine size is useful for exclusion of endometrial pathology and to avoid unnecessary invasive surgical procedures.


Author(s):  
Dr. Rujuta Acharya

INTRODUCTION:  The early detection of the risk of PE may improve the outcome by increasing patient surveillance or by initiating a therapeutic intervention. After taking family history and medical history of obstetric events, hypertension, renal disease, or thrombophilia can help to stratify the risk of hypertensive disorders of pregnancy and history alone will identify fewer than half the women who later develop pre-eclampsia. Routine screening for specific risk factors for pre-eclampsia  i.e. nullipara, older age, high body mass index (BMI), family history of pre-eclampsia,  multiple pregnancy, more than 10 years between pregnancies, and a personal history of pre-eclampsia is advised. MATERIAL AND METHODS:Detail history of all the participants was taken which comprises of age, parity, and past obstetric complications. Medical history was taken and pregnant ladies. Blood pressure measurement was done by standard mercury sphygmomanometer. Mean arterial pressure was calculated by Burton’s formula. Waist circumference was measured midway between the lowest rib and the iliac crest. Waist circumference of >80 cm was used as a cut off. RESULTS: Majority of the patients who developed pre eclampsia were in the age group of 20 to 25 years (66%).in our study primigravida were 60% who developed pre eclampsia. In our study 40 (20%) had mean arterial pressure >90 mmHg 22 developed preeclampsia while out of 160 (80%) patients having mean arterial pressure <90 mmHg 24 developed preeclampsia. sensitivity, specificity, positive predictive value and negative predictive value was 47.83 %, 88.31 %, 55.00% and 85.00 % respectively.86 women had waist circumference >80 cm out of 80 women 34 developed preeclampsia while 52 were normotensive. Out of 114 women having waist circumference <80 cm 12 developed preeclampsia while 102 remain normotensive with sensitivity, specificity, positive predictive value and negative predictive value of 73.91%, 66.23%, 39.53% and 89.47% respectively. CONCLUSION: Mean arterial pressure is a good predictor of preeclampsia with high specificity and negative predictive value. Waist circumference is a simple, and reproducible method with high negative predictive value.


2013 ◽  
Vol 79 (1) ◽  
pp. 101-106 ◽  
Author(s):  
Jong Seob Park ◽  
Jin Ho Jeong ◽  
Jong In Lee ◽  
Jong Hoon Lee ◽  
Jea Kun Park ◽  
...  

The objectives were to evaluate the effectiveness of ultrasonography, computed tomography, and physical examination for diagnosing acute appendicitis with analyzing their accuracies and negative appendectomy rates in a clinical rather than research setting. A total of 2763 subjects were enrolled. Sensitivity, specificity, positive predictive value, and negative predictive value and negative appendectomy rate for ultrasonography, computed tomography, and physical examination were calculated. Confirmed positive acute appendicitis was defined based on pathologic findings, and confirmed negative acute appendicitis was defined by pathologic findings as well as on clinical follow-up. Sensitivity, specificity, positive predictive value, and negative predictive value for ultrasonography were 99.1, 91.7, 96.5, and 97.7 per cent, respectively; for computed tomography, 96.4, 95.4, 95.6, and 96.3 per cent, respectively; and for physical examination, 99.0, 76.1, 88.1, and 97.6 per cent, respectively. The negative appendectomy rate was 5.8 per cent (5.2% in the ultrasonography group, 4.3% in the computed tomography group, and 12.2% in the physical examination group). Ultrasonography/computed tomography should be performed routinely for diagnosis of acute appendicitis. However, in view of its advantages, ultrasonography should be performed first. Also, if the result of a physical examination is negative, imaging studies after physical examination can be unnecessary.


Medicina ◽  
2021 ◽  
Vol 57 (5) ◽  
pp. 503
Author(s):  
Thomas F. Monaghan ◽  
Syed N. Rahman ◽  
Christina W. Agudelo ◽  
Alan J. Wein ◽  
Jason M. Lazar ◽  
...  

Sensitivity, which denotes the proportion of subjects correctly given a positive assignment out of all subjects who are actually positive for the outcome, indicates how well a test can classify subjects who truly have the outcome of interest. Specificity, which denotes the proportion of subjects correctly given a negative assignment out of all subjects who are actually negative for the outcome, indicates how well a test can classify subjects who truly do not have the outcome of interest. Positive predictive value reflects the proportion of subjects with a positive test result who truly have the outcome of interest. Negative predictive value reflects the proportion of subjects with a negative test result who truly do not have the outcome of interest. Sensitivity and specificity are inversely related, wherein one increases as the other decreases, but are generally considered stable for a given test, whereas positive and negative predictive values do inherently vary with pre-test probability (e.g., changes in population disease prevalence). This article will further detail the concepts of sensitivity, specificity, and predictive values using a recent real-world example from the medical literature.


2021 ◽  
Vol 10 (1) ◽  
pp. 20-25
Author(s):  
Sujan Shrestha ◽  
Mamen Prasad Gorhaly ◽  
Manil Ratna Bajracharya

Background Diabetic peripheral neuropathy (DPN) is a significant independent risk factor for diabetic foot, and an effective screening instrument is required to diagnose DPN early to prevent future ulceration and amputation. This study aims to determine the diagnostic accuracy of monofilament test to detect diabetic peripheral neuropathy. Methods This cross-sectional study was conducted in National Academy of Medical Sciences, Bir hospital, Mahabouddha, Kathmandu from February 2016 to January 2017. A total of 96 diabetic patients attending inpatient and outpatient Department were selected. Diabetic peripheral neuropathy was assessed by measurement of loss of protective sensation (LOPS) by monofilament test and compared with vibration perception threshold by standard biothesiometer. The sensitivity, specificity, positive predictive value and negative predictive value of monofilament test were calculated. Results The prevalence of diabetic peripheral neuropathy was 26%. The sensitivity, specificity, positive predictive value and negative predictive value of monofilament test were found to be 92.0%, 95.8%, 88.5% and 97.1% respectively. There was strong association between LOPS by monofilament and vibration perception threshold by biothesiometer. Conclusion This study showed a strong diagnostic accuracy of monofilament test to detect DPN when compared with biothesiometer. As monofilament test is a cheap, easily available, and portable, it can be used in the periphery where biothesiometer is not available.  


2021 ◽  
Vol 5 (1) ◽  
Author(s):  
Tahir Iqbal ◽  
Muhammad Usman Shahid ◽  
Ishfaq Ahmad Shad ◽  
Shahzad Karim Bhatti ◽  
Syed Amir Gilani ◽  
...  

ABSTRACT: BACKGROUND: A common surgical emergency is acute appendicitis. Various diagnostic tools are available to diagnosis acute appendicitis. Radiological investigations play an important role in making accurate and early diagnosis and thus preventing morbidity associated with the disease. OBJECTIVE: To determine the diagnostic accuracy of gray scale ultrasonography versus color Doppler in suspected cases of acute appendicitis. MATERIALS AND METHODS: The study was carried in the department of Radiology of Mayo Hospital, Lahore. A total of 75 patients were enrolled of age 18-40 years, both genders who were suspected cases of acute appendicitis. All patients underwent baseline investigations along with gray scale ultrasonography and color Doppler. All patients were subjected to surgery to confirm the diagnosis and findings were subjected to statistical analysis. RESULTS: The mean age of the patients was 23.25 ±10.55 and mean transverse diameter of appendix was 8.37 ±3.39. There were 62.7% males and 37.3%females. Findings of gray scale ultrasonography and color Doppler were then correlated with surgical findings to calculate the diagnostic accuracy of these modalities. The results revealed that gray scale ultrasonography sensitivity, specificity, positive predictive value, negative predictive value and accuracy was 92.7%, 94.32%, 95%, 91.4% and 93.3% respectively, whereas color Doppler had sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 97.7%, 93.9%, 95.3%, 97% and 96% respectively. Diagnostic accuracy of both modalities together was 98.6%. CONCLUSION: Color Doppler has better diagnostic accuracy than gray scale ultrasonography for diagnosis of acute appendicitis and the combination of both modalities yields diagnostic accuracy that is similar to gold standard.


Author(s):  
Badugu Rao Bahadur ◽  
Gangadhara Rao Koneru ◽  
Prabha Devi Kodey ◽  
Jyothi Melam

Background: To differentiate ovarian mass as benign or malignant could change clinical approach. Finding a screening and diagnostic method for ovarian cancer is challenging due to high mortality and insidious symptoms. Risk malignancy index (RMI) has the advantage of rapid and exact triage of patients with ovarian mass.Methods: Prospective study carried for 2 years at NRI Medical College and General Hospital, Chinakakani, Mangalagiri, Andhra Pradesh, India. 79 patients with ovarian mass were investigated and risk malignancy index (RMI-3 and RMI-4) calculated. Final confirmation was done based on histopathological report. Sensitivity, specificity, positive predictive value and negative predictive value were calculated for RMI 3 and RMI 4 taking histopathology as control and comparison was done.Results: (n=79); 50 (63.29%) cases were benign and 29 (36.70%) were malignant based on histopathology. RMI 4 is more sensitive (68.96%) than RMI 3 (62.06%), but RMI 3 is more specific (94%) than RMI 4 (92%).The positive predictive value of RMI-3 and RMI-4 were 85.71%  and 83.33% respectively. The negative predictive value for RMI-4 and RMI-3 were 83.63% and 81.03% respectively.Conclusions: With increasing age, chance of malignancy increases. RMI 4 was more sensitive than RMI-3, however less specific than RMI 3 in differentiating benign and malignant tumors. The positive predictive value is slightly more for RMI 3, than RMI 4. Negative predictive value is slightly more for RMI 4, than RMI 3. 


2017 ◽  
Author(s):  
Ευστάθιος Δράμπαλος

Σκοπός: H εφαρμογή για πρώτη φορά διεθνώς της μορφομετρίας της σπονδυλικής στήλης με χρήση απορροφησιομετρίας (VFA) σε ασθενείς με κυφοπλαστική. Αναλύονται τα πλεονεκτήματα και μειονεκτήματα της μεθόδου, ελέγχεται η αξιοπιστία της και συγκρίνεται με την μορφομετρία κατά τον κλασσικό ακτινολογικό έλεγχο (ΜRΧ) στην εκτίμηση των σπονδυλικών παραμορφώσεων στους συγκεκριμένους ασθενείς.Υλικά και Μέθοδος: Πραγματοποιήθηκαν μετρήσεις σε 42 ασθενείς με κυφοπλαστική λόγω οστεοπορωτικών σπονδυλικών καταγμάτων και αναλύθηκαν οι σπόνδυλοι από τον T4 μέχρι τον L4 με την VFA και την MRX. Μετρήθηκαν το πρόσθιο (ha), μέσο (hm) και οπίσθιο (hp) ύψος του σπονδυλικού σώματος και προσδιορίσθηκαν οι λόγοι ha/hp και hm/hp. Αναλύθηκαν για την VFA η συμφωνία αποτελεσμάτων του ίδιου παρατηρητή (IOA) και η συμφωνία αποτελεσμάτων μεταξύ ανεξάρτητων παρατηρητών (INA) για τους λόγους ha/hp και hm/hp καθώς και για την μέθοδο Genant σε επίπεδο σπονδύλου, ‘περιοχής της σπονδυλικής στήλης (θωρακική/ΘΜΣΣ ή οσφυϊκή/ΟΜΣΣ), σε επίπεδο ‘γειτονικών προς την κυφοπλαστική σπονδύλων’, και σε επίπεδο ‘σπονδύλων με κυφοπλαστική’. Σε κάθε επίπεδο χρησιμοποιήθηκε η μέση τιμή ha/hp και hm/hp. Στη συνέχεια, αναλύσαμε την συμφωνία μεταξύ VFA και MRX στον καθορισμό των λόγων ha/hp και hm/hp καθώς και μετά την διχοτόμηση των λόγων ha/hp περί της τιμής όριο που συνήθως χρησιμοποιείται για τον καθορισμό ενός κατάγματος. Αποτελέσματα: Οι IOA και INA για τους λόγους ha/hp και hm/hp στην VFA ήταν ‘σχεδόν τέλεια’ σε όλα τα επίπεδα (ICC 0.94-0.98). Η εφαρμογή της μεθόδου Genant κατά την VFA ανέδειξε επίσης ‘σχεδόν τέλεια’ INA (ICC=0.833). Η ανάλυση σε επίπεδο σπονδύλου έδειξε ‘σχεδόν τέλεια’ συμφωνία μεταξύ VFA και MRX για τον λόγο ha/hp [intraclass correlation coefficient, ICC=0.85], και ‘ισχυρή συμφωνία’ για τον λόγο hm/hp (ICC=0.78). Για τον λόγο ha/hp η συμφωνία ήταν ‘σχεδόν τέλεια’ τόσο στην ΘΜΣΣ (ICC=0.82) όσο και στην ΟΜΣΣ (ICC=0.87), ενώ για τον λόγο hm/hp η συμφωνία ήταν ‘ισχυρή’ στην ΘΜΣΣ (ICC=0.75) και ‘σχεδόν τέλεια’ στην ΟΜΣΣ (ICC=0.80). Η συμφωνία ήταν εξίσου ‘σχεδόν τέλεια’ σε επίπεδο ‘σπονδύλων με κυφοπλαστική’ (ICC=0.83) όσο και σε επίπεδο ‘γειτονικών προς την κυφοπλαστική σπονδύλων’ (ICC=0.80) για τον λόγο ha/hp. Όταν οι λόγοι ha/hp μετατράπηκαν σε κατάγματα (ναι ή όχι κάταγμα) χρησιμοποιώντας διαφορετικές τιμές κατώφλι για την διάγνωση κατάγματος (λόγοι ha/hp 0.75, 0.80 και 0.85) η συμφωνία μεταξύ των μεθόδων ήταν λιγότερο καλή, από μέτρια έως ουσιώδης (κ 0.52-0.63 στην ΟΜΣΣ και 0.53-0.66 στην ΘΜΣΣ). Χρησιμοποιώντας την κατάταξη Genant οι διαφορές στην ταξινόμηση των σπονδύλων ήταν περισσότερο προς την κατεύθυνση της MRX με 32 αναγνωρισμένα κατάγματα μόνο από την MRX και μόνο 5 μόνο από την VFA. Στη μελέτη αυτή, με επιπολασμό σφηνοειδών σπονδυλικών καταγμάτων 9.3%, οι δείκτες ακρίβειας sensitivity, specificity, positive predictive value (PPV) και negative predictive value (NPV) υπολογίστηκαν σε 0.522, 0.97, 0.87 και 0.92 αντίστοιχα. Συμπεράσματα: Η εφαρμογή της VFA σε ασθενείς με κυφοπλαστική έχει υψηλή επαναληψιμότητα και αναπαραγωγιμότητα. Η συμφωνία μεταξύ VFA και MRX στην εκτίμηση των λόγων ha/hp και hm/hm ήταν από ‘ισχυρή’ έως ‘σχεδόν τέλεια’ ανάλογα με το επίπεδο εξέτασης. Η συμφωνία στην αναγνώριση των σπονδυλικών καταγμάτων ήταν μέτρια. Οι διαφορές ήταν περισσότερο προς την κατεύθυνση της MRX. Η υψηλή τιμή του δείκτη NPV της VFA στους ασθενείς με κυφοπλαστική, δείχνει ότι η μέθοδος θα μπορούσε να χρησιμοποιηθεί για τον εντοπισμό αυτών που χρήζουν περαιτέρω ακτινολογικού ελέγχου.


Sign in / Sign up

Export Citation Format

Share Document