In vivoimaging flow cytometry based on laser scanning two-photon microscopy at kHz cross-sectional frame rate

2016 ◽  
Author(s):  
Lingjie Kong ◽  
Jianyong Tang ◽  
Meng Cui
2012 ◽  
Vol 32 (7) ◽  
pp. 1277-1309 ◽  
Author(s):  
Andy Y Shih ◽  
Jonathan D Driscoll ◽  
Patrick J Drew ◽  
Nozomi Nishimura ◽  
Chris B Schaffer ◽  
...  

The cerebral vascular system services the constant demand for energy during neuronal activity in the brain. Attempts to delineate the logic of neurovascular coupling have been greatly aided by the advent of two-photon laser scanning microscopy to image both blood flow and the activity of individual cells below the surface of the brain. Here we provide a technical guide to imaging cerebral blood flow in rodents. We describe in detail the surgical procedures required to generate cranial windows for optical access to the cortex of both rats and mice and the use of two-photon microscopy to accurately measure blood flow in individual cortical vessels concurrent with local cellular activity. We further provide examples on how these techniques can be applied to the study of local blood flow regulation and vascular pathologies such as small-scale stroke.


2018 ◽  
Author(s):  
Abbas Kazemipour ◽  
Ondrej Novak ◽  
Daniel Flickinger ◽  
Jonathan S. Marvin ◽  
Jonathan King ◽  
...  

SummaryPoint-scanning two-photon microscopy enables high-resolution imaging within scattering specimens such as the mammalian brain, but sequential acquisition of voxels fundamentally limits imaging speed. We developed a two-photon imaging technique that scans lines of excitation across a focal plane at multiple angles and uses prior information to recover high-resolution images at over 1.4 billion voxels per second. Using a structural image as a prior for recording neural activity, we imaged visually-evoked and spontaneous glutamate release across hundreds of dendritic spines in mice at depths over 250 µm and frame-rates over 1 kHz. Dendritic glutamate transients in anaesthetized mice are synchronized within spatially-contiguous domains spanning tens of microns at frequencies ranging from 1-100 Hz. We demonstrate high-speed recording of acetylcholine and calcium sensors, 3D single-particle tracking, and imaging in densely-labeled cortex. Our method surpasses limits on the speed of raster-scanned imaging imposed by fluorescence lifetime.


2004 ◽  
Vol 92 (5) ◽  
pp. 3121-3133 ◽  
Author(s):  
Juergen C. Jung ◽  
Amit D. Mehta ◽  
Emre Aksay ◽  
Raymond Stepnoski ◽  
Mark J. Schnitzer

One of the major limitations in the current set of techniques available to neuroscientists is a dearth of methods for imaging individual cells deep within the brains of live animals. To overcome this limitation, we developed two forms of minimally invasive fluorescence microendoscopy and tested their abilities to image cells in vivo. Both one- and two-photon fluorescence microendoscopy are based on compound gradient refractive index (GRIN) lenses that are 350–1,000 μm in diameter and provide micron-scale resolution. One-photon microendoscopy allows full-frame images to be viewed by eye or with a camera, and is well suited to fast frame-rate imaging. Two-photon microendoscopy is a laser-scanning modality that provides optical sectioning deep within tissue. Using in vivo microendoscopy we acquired video-rate movies of thalamic and CA1 hippocampal red blood cell dynamics and still-frame images of CA1 neurons and dendrites in anesthetized rats and mice. Microendoscopy will help meet the growing demand for in vivo cellular imaging created by the rapid emergence of new synthetic and genetically encoded fluorophores that can be used to label specific brain areas or cell classes.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Malo Daniel ◽  
Laurence Dubreil ◽  
Romain Fleurisson ◽  
Jean-Paul Judor ◽  
Timothée Bresson ◽  
...  

Abstract The development of innovative immune cell therapies relies on efficient cell tracking strategies. For this, multiscale fluorescence-based analyses of transferred cells into the host with complementary techniques, including flow cytometry for high-throughput cell analysis and two-photon microscopy for deep tissue imaging would be highly beneficial. Ideally, cells should be labelled with a single fluorescent probe combining all the properties required for these different techniques. Due to the intrinsic autofluorescence of most tissues and especially the liver, far-red emission is also an important asset. However, the development of far-red emitting probes suitable for two-photon microscopy and compatible with clearing methods to track labelled immune cells in thick samples, remains challenging. A newly-designed water-soluble far-red emitting polymer probe, 19K-6H, with a large Stokes shift, was thus evaluated for the tracking of primary immune CD8 T cells. These cells, prepared from mouse spleen, were efficiently labelled with the 19K-6H probe, which was internalized via endocytosis and was highly biocompatible at concentrations up to 20 μM. Labelled primary CD8 T cells were detectable in culture by both confocal and two-photon microscopy as well as flow cytometry, even after 3 days of active proliferation. Finally, 19K-6H-labelled primary CD8 T cells were injected to mice in a classical model of immune mediated hepatitis. The efficient tracking of the transferred cells in the liver by flow cytometry (on purified non-parenchymal cells) and by two-photon microscopy on 800 μm thick cleared sections, demonstrated the versatility of the 19K-6H probe.


2016 ◽  
Author(s):  
Alexander Song ◽  
Adam S. Charles ◽  
Sue Ann Koay ◽  
Jeff L. Gauthier ◽  
Stephan Y. Thiberge ◽  
...  

AbstractTwo-photon laser scanning microscopy of calcium dynamics using fluorescent indicators is a widely used imaging method for large scale recording of neural activity in vivo. Here we introduce volumetric Two-photon Imaging of Neurons using Stereoscopy (vTwINS), a volumetric calcium imaging method that employs an elongated, V-shaped point spread function to image a 3D brain volume. Single neurons project to spatially displaced image pairs in the resulting 2D image, and the separation distance between images is proportional to depth in the volume. To demix the fluorescence time series of individual neurons, we introduce a novel orthogonal matching pursuit algorithm that also infers source locations within the 3D volume. We illustrate vTwINS by imaging neural population activity in mouse primary visual cortex and hippocampus. Our results demonstrate that vTwINS provides an effective method for volumetric two-photon calcium imaging that increases the number of neurons recorded while maintaining a high frame-rate.


2021 ◽  
pp. 127804
Author(s):  
Aurelio Paez ◽  
Emma M. Sundin ◽  
Gilberto Navarro ◽  
Xiujun Li ◽  
Thomas Boland ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document