Digital image capture for high-resolution medical x-ray diagnostics

Author(s):  
Nicholas A. Mostovych ◽  
Theodore F. Morse ◽  
Rajiv Gupta ◽  
Timothy P. Murphy ◽  
Peter M. Weber ◽  
...  
Energies ◽  
2020 ◽  
Vol 13 (13) ◽  
pp. 3378
Author(s):  
Martin Beer ◽  
Marcela Taušová ◽  
Radim Rybár ◽  
Michal Kaľavský

The presented paper deals with the metal foams, which have a wide application potential ranging from power engineering, through catalysts to impact energy absorbers. The main aim of the paper is to propose an economical non-destructive method of determining the basic characteristics and dimensions using affordable devices. The basic principle of the proposed method lies in the image capture of metal foam and their subsequent analysis in image analysis software. An important element of the work is a comparison of results obtained by the proposed method with results obtained by high-resolution X-ray microtomography. The proposed method was evaluated in terms of measurement uncertainty and propagation of error in overall results. The use of the method is limited to the metal foams, characterized by an ordered structure, which are produced mainly by the electrophoretic deposition process. Based on the descriptive statistical analysis of results, it is possible to state, that the proposed method is in great agreement with accurate, but more expensive high-resolution X-ray microtomography.


Author(s):  
Robert A. Grant ◽  
Laura L. Degn ◽  
Wah Chiu ◽  
John Robinson

Proteolytic digestion of the immunoglobulin IgG with papain cleaves the molecule into an antigen binding fragment, Fab, and a compliment binding fragment, Fc. Structures of intact immunoglobulin, Fab and Fc from various sources have been solved by X-ray crystallography. Rabbit Fc can be crystallized as thin platelets suitable for high resolution electron microscopy. The structure of rabbit Fc can be expected to be similar to the known structure of human Fc, making it an ideal specimen for comparing the X-ray and electron crystallographic techniques and for the application of the molecular replacement technique to electron crystallography. Thin protein crystals embedded in ice diffract to high resolution. A low resolution image of a frozen, hydrated crystal can be expected to have a better contrast than a glucose embedded crystal due to the larger density difference between protein and ice compared to protein and glucose. For these reasons we are using an ice embedding technique to prepare the rabbit Fc crystals for molecular structure analysis by electron microscopy.


Author(s):  
G. Van Tendeloo ◽  
J. Van Landuyt ◽  
S. Amelinckx

Polytypism has been studied for a number of years and a wide variety of stacking sequences has been detected and analysed. SiC is the prototype material in this respect; see e.g. Electron microscopy under high resolution conditions when combined with x-ray measurements is a very powerful technique to elucidate the correct stacking sequence or to study polytype transformations and deviations from the ideal stacking sequence.


Author(s):  
R. Gronsky

The phenomenon of clustering in Al-Ag alloys has been extensively studied since the early work of Guinierl, wherein the pre-precipitation state was characterized as an assembly of spherical, ordered, silver-rich G.P. zones. Subsequent x-ray and TEM investigations yielded results in general agreement with this model. However, serious discrepancies were later revealed by the detailed x-ray diffraction - based computer simulations of Gragg and Cohen, i.e., the silver-rich clusters were instead octahedral in shape and fully disordered, atleast below 170°C. The object of the present investigation is to examine directly the structural characteristics of G.P. zones in Al-Ag by high resolution transmission electron microscopy.


Author(s):  
Yun Lu ◽  
David C. Joy

High resolution scanning electron microscopy (SEM) and energy dispersive x-ray analysis (EDXA) were performed to investigate microparticles in blended cements and their hydration products containing sodium-rich chemical wastes. The physical appearance of powder particles and the morphological development at different hydration stages were characterized by using high resolution SEM Hitachi S-900 and by SEM S-800 with a EDX spectrometer. Microparticles were dispersed on the sample holder and glued by 1% palomino solution. Hydrated bulk samples were dehydrated by acetone and mounted on the holder by silver paste. Both fracture surfaces and flat cutting sections of hydrating samples were prepared and examined. Some specimens were coated with an 3 nm thick Au-Pd or Cr layer to provide good conducting surfaces. For high resolution SEM S-900 observations the accelerating voltage of electrons was 1-2 KeV to protect the electron charging. Microchemical analyses were carried out by S800/EDS equipped with a LINK detector of take-off angle =40°.


Author(s):  
K. H. Downing ◽  
S. G. Wolf ◽  
E. Nogales

Microtubules are involved in a host of critical cell activities, many of which involve transport of organelles through the cell. Different sets of microtubules appear to form during the cell cycle for different functions. Knowledge of the structure of tubulin will be necessary in order to understand the various functional mechanisms of microtubule assemble, disassembly, and interaction with other molecules, but tubulin has so far resisted crystallization for x-ray diffraction studies. Fortuitously, in the presence of zinc ions, tubulin also forms two-dimensional, crystalline sheets that are ideally suited for study by electron microscopy. We have refined procedures for forming the sheets and preparing them for EM, and have been able to obtain high-resolution structural data that sheds light on the formation and stabilization of microtubules, and even the interaction with a therapeutic drug.Tubulin sheets had been extensively studied in negative stain, demonstrating that the same protofilament structure was formed in the sheets and microtubules. For high resolution studies, we have found that the sheets embedded in either glucose or tannin diffract to around 3 Å.


Author(s):  
Ralph M. Albrecht ◽  
Scott R. Simmons ◽  
Marek Malecki

The development of video-enhanced light microscopy (LM) as well as associated image processing and analysis have significantly broadened the scope of investigations which can be undertaken using (LM). Interference/polarization based microscopies can provide high resolution and higher levels of “detectability” especially in unstained living systems. Confocal light microscopy also holds the promise of further improvements in resolution, fluorescence studies, and 3 dimensional reconstruction. Video technology now provides, among other things, a means to detect differences in contrast difficult to detect with the human eye; furthermore, computerized image capture, processing, and analysis can be used to enhance features of interest, average images, subtract background, and provide a quantitative basis to studies of cells, cell features, cell labelling, and so forth. Improvements in video technology, image capture, and cost-effective computer image analysis/processing have contributed to the utility and potential of the various interference and confocal microscopic instrumentation.Electron microscopic technology has made advances as well. Microprocessor control and improved design have contributed to high resolution SEMs which have imaging capability at the molecular level and can operate at a range of accelerating voltages starting at 1KV. Improvements have also been seen in the HVEM and IVEM transmission instruments. As a whole, these advances in LM and EM microscopic technology provide the biologist with an array of information on structure, composition, and function which can be obtained from a single specimen. Corrrelative light microscopic analysis permits examination of living specimens and is critical where the “history” of a cell, cellular components, or labels needs to be known up to the time of chemical or physical fixation. Features such as cytoskeletal elements or gold label as small as 0.01 μm, well below the 0.2 μm limits of LM resolution, can be “detected” and their movement followed by VDIC-LM. Appropriate identification and preparation can then lead to the examination of surface detail and surface label with stereo LV-HR-SEM. Increasing the KV in the HR-SEM while viewing uncoated or thinly coated specimens can provide information from beneath the surface as well as increasing Z contrast so that positive identification of surface and subsurface colloidal gold or other heavy metal labelled/stained material is possible. Further examination of the same cells using stereo HVEM or IVEM provides information on internal ultrastructure and on the relationship of labelled material to cytoskeletal or organellar distribution, A wide variety of investigations can benefit from this correlative approach and a number of instrumentational configurations and preparative pathways can be tailored for the particular study. For a surprisingly small investment in time and technique, it is often possible to clear ambiguities or questions that arise when a finding is presented in the context of only one modality.


Author(s):  
Y. Y. Wang ◽  
H. Zhang ◽  
V. P. Dravid ◽  
H. Zhang ◽  
L. D. Marks ◽  
...  

Azuma et al. observed planar defects in a high pressure synthesized infinitelayer compound (i.e. ACuO2 (A=cation)), which exhibits superconductivity at ~110 K. It was proposed that the defects are cation deficient and that the superconductivity in this material is related to the planar defects. In this report, we present quantitative analysis of the planar defects utilizing nanometer probe xray microanalysis, high resolution electron microscopy, and image simulation to determine the chemical composition and atomic structure of the planar defects. We propose an atomic structure model for the planar defects.Infinite-layer samples with the nominal chemical formula, (Sr1-xCax)yCuO2 (x=0.3; y=0.9,1.0,1.1), were prepared using solid state synthesized low pressure forms of (Sr1-xCax)CuO2 with additions of CuO or (Sr1-xCax)2CuO3, followed by a high pressure treatment.Quantitative x-ray microanalysis, with a 1 nm probe, was performed using a cold field emission gun TEM (Hitachi HF-2000) equipped with an Oxford Pentafet thin-window x-ray detector. The probe was positioned on the planar defects, which has a 0.74 nm width, and x-ray emission spectra from the defects were compared with those obtained from vicinity regions.


Author(s):  
W. Coene ◽  
F. Hakkens ◽  
T.H. Jacobs ◽  
K.H.J. Buschow

Intermetallic compounds of the type RE2Fe17Cx (RE= rare earth element) are promising candidates for permanent magnets. In case of Y2Fe17Cx, the Curie temperature increases from 325 K for x =0 to 550 K for x = 1.6 . X ray and electron diffraction reveal a carbon - induced structural transformation in Y2Fe17Cx from the hexagonal Th2Ni17 - type (x < 0.6 ) to the rhombohedral Th2Zn17 - type ( x ≥ 0.6). Planar crystal defects introduce local sheets of different magnetic anisotropy as compared with the ordered structure, and therefore may have an important impact on the coercivivity mechanism .High resolution electron microscopy ( HREM ) on a Philips CM30 / Super Twin has been used to characterize planar crystal defects in rhombohedral Y2Fe17Cx ( x ≥ 0.6 ). The basal plane stacking sequences are imaged in the [100] - orientation, showing an ABC or ACB sequence of Y - atoms and Fe2 - dumbbells, for both coaxial twin variants, respectively . Compounds resulting from a 3 - week annealing treatment at high temperature ( Ta = 1000 - 1100°C ) contain a high density of planar defects.


1978 ◽  
Vol 3 ◽  
pp. 357-357
Author(s):  
J. Als-Nielsen ◽  
R. J. Birgeneau ◽  
M. Kaplan ◽  
J. D. Litster ◽  
C. R. Safinya
Keyword(s):  
X Ray ◽  

Sign in / Sign up

Export Citation Format

Share Document