Design of a multi-material loaded soft tissue phantom for the estimation of phase maps using a single exposure x-ray phase retrieval method

Author(s):  
Muhammad U. Ghani ◽  
Aimin Yan ◽  
Yuchen Qui ◽  
Wei Chen ◽  
Xizeng Wu ◽  
...  
2016 ◽  
Vol 40 (2) ◽  
pp. 029001
Author(s):  
Heng Chen ◽  
Kun Gao ◽  
Da-Jiang Wang ◽  
Li Song ◽  
Zhi-Li Wang

2018 ◽  
Vol 45 (9) ◽  
pp. 4191-4200 ◽  
Author(s):  
Hao Lei ◽  
Wei Zhang ◽  
Ibrahim Oraiqat ◽  
Zhipeng Liu ◽  
Jun Ni ◽  
...  

2011 ◽  
Author(s):  
Kentaro Nagai ◽  
Hidenosuke Itoh ◽  
Genta Sato ◽  
Takashi Nakamura ◽  
Kimiaki Yamaguchi ◽  
...  

2015 ◽  
Vol 42 (2) ◽  
pp. 741-749 ◽  
Author(s):  
Zhao Wu ◽  
Kun Gao ◽  
Jian Chen ◽  
Dajiang Wang ◽  
Shenghao Wang ◽  
...  

2019 ◽  
Vol 46 (3) ◽  
pp. 1317-1322
Author(s):  
Zhili Wang ◽  
Kun Ren ◽  
Xiaomin Shi ◽  
Dalin Liu ◽  
Zhao Wu ◽  
...  

2021 ◽  
Vol 11 (9) ◽  
pp. 4120
Author(s):  
Benedicta D. Arhatari ◽  
Andrew W. Stevenson ◽  
Brian Abbey ◽  
Yakov I. Nesterets ◽  
Anton Maksimenko ◽  
...  

The Imaging and Medical Beamline (IMBL) is a superconducting multipole wiggler-based beamline at the 3 GeV Australian Synchrotron operated by the Australian Nuclear Science and Technology Organisation (ANSTO). The beamline delivers hard X-rays in the 25–120 keV energy range and offers the potential for a range of biomedical X-ray applications, including radiotherapy and medical imaging experiments. One of the imaging modalities available at IMBL is propagation-based X-ray phase-contrast computed tomography (PCT). PCT produces superior results when imaging low-density materials such as soft tissue (e.g., breast mastectomies) and has the potential to be developed into a valuable medical imaging tool. We anticipate that PCT will be utilized for medical breast imaging in the near future with the advantage that it could provide better contrast than conventional X-ray absorption imaging. The unique properties of synchrotron X-ray sources such as high coherence, energy tunability, and high brightness are particularly well-suited for generating PCT data using very short exposure times on the order of less than 1 min. The coherence of synchrotron radiation allows for phase-contrast imaging with superior sensitivity to small differences in soft-tissue density. Here we also compare the results of PCT using two different detectors, as these unique source characteristics need to be complemented with a highly efficient detector. Moreover, the application of phase retrieval for PCT image reconstruction enables the use of noisier images, potentially significantly reducing the total dose received by patients during acquisition. This work is part of ongoing research into innovative tomographic methods aimed at the introduction of 3D X-ray medical imaging at the IMBL to improve the detection and diagnosis of breast cancer. Major progress in this area at the IMBL includes the characterization of a large number of mastectomy samples, both normal and cancerous, which have been scanned at clinically acceptable radiation dose levels and evaluated by expert radiologists with respect to both image quality and cancer diagnosis.


Sign in / Sign up

Export Citation Format

Share Document