High-accuracy multi-step eigenvalue calibration method for Mueller matrix polarization imaging system

Author(s):  
Jianhui Li ◽  
Yanqiu Li ◽  
Guodong Zhou ◽  
Jiazhi Wang ◽  
Meng Zheng ◽  
...  
2002 ◽  
Vol 7 (3) ◽  
pp. 341 ◽  
Author(s):  
Justin S. Baba ◽  
Jung-Rae Chung ◽  
Aimee H. DeLaughter ◽  
Brent D. Cameron ◽  
Gerard L. Coté

2015 ◽  
Vol 73 ◽  
pp. 269-274 ◽  
Author(s):  
Lixiang Geng ◽  
Qian Chen ◽  
Weixian Qian ◽  
Guohua Gu

Optik ◽  
2019 ◽  
Vol 180 ◽  
pp. 1027-1035
Author(s):  
Xiaotian Lu ◽  
Jie Yang ◽  
Li Li ◽  
Weiqi Jin ◽  
Hengze Wu ◽  
...  

2021 ◽  
Vol 11 (12) ◽  
pp. 5628
Author(s):  
Run Fang ◽  
Libo Zeng ◽  
Fan Yi

Multi-spectral imaging technique plays an important role in real-world applications such as medicine and medical detections. This paper proposes a cervical cancer cell screening method to simultaneously adopt TBS classification and DNA quantitative analysis for a single cell smear. Through using compound staining on a smear, the cytoplasm is stained by Papanicolauo and the nucleus is stained by Feulgen. The main evaluation parameter is the DNA content of the nucleus, not the subjective description of cell morphology, which is more objective than the TBS classification method and reduces the chances of missing a diagnosis due to subjective factors. Each nucleus has its own DI value and color image of the whole cell, which is convenient for doctors as it allows them to review and confirm the morphology of cells with a nucleus DI of over 2.5. Mouse liver smears and cervical cases are utilized as the measuring specimens to evaluate the performance of the microscope multi-spectral imaging system; illustrative results demonstrate that the proposed system qualifies, with high accuracy and reliability, and further presents wide application prospects in the early diagnosis of cervical cancer.


Sensors ◽  
2018 ◽  
Vol 18 (9) ◽  
pp. 2842 ◽  
Author(s):  
Wei Liu ◽  
Bing Liang ◽  
Zhenyuan Jia ◽  
Di Feng ◽  
Xintong Jiang ◽  
...  

High precision position control is essential in the process of parts manufacturing and assembling, where eddy current displacement sensors (ECDSs) are widely used owing to the advantages of non-contact sensing, compact volume, and resistance to harsh conditions. To solve the nonlinear characteristics of the sensors, a high-accuracy calibration method based on linearity adjustment is proposed for ECDSs in this paper, which markedly improves the calibration accuracy and then the measurement accuracy. After matching the displacement value and the output voltage of the sensors, firstly, the sensitivity is adjusted according to the specified output range. Then, the weighted support vector adjustment models with the optimal weight of the zero-scale, mid-scale and full-scale are established respectively to cyclically adjust the linearity of the output characteristic curve. Finally, the final linearity adjustment model is obtained, and both the calibration accuracy and precision are verified by the established calibration system. Experimental results show that the linearity of the output characteristic curve of ECDS adjusted by the calibration method reaches over 99.9%, increasing by 1.9–5.0% more than the one of the original. In addition, the measurement accuracy improves from 11–25 μ m to 1–10 μ m in the range of 6mm, which provides a reliable guarantee for high accuracy displacement measurement.


2016 ◽  
Vol 9 (10) ◽  
pp. 4977-4995 ◽  
Author(s):  
Guillaume Merlin ◽  
Jérôme Riedi ◽  
Laurent C. Labonnote ◽  
Céline Cornet ◽  
Anthony B. Davis ◽  
...  

Abstract. Information content analyses on cloud top altitude (CTOP) and geometrical thickness (CGT) from multi-angular A-band measurements in the case of monolayer homogeneous clouds are conducted. In the framework of future multi-angular radiometer development, we compared the potential performances of the 3MI (Multi-viewing, Multi-channel and Multi-polarization Imaging) instrument developed by EUMETSAT, which is an extension of POLDER/PARASOL instrument and MSPI (Multiangle SpectroPolarimetric Imager) developed by NASA's Jet Propulsion Laboratory. Quantitative information content estimates were realized for thin, moderately opaque and opaque clouds for different surface albedo and viewing geometry configurations. Analyses show that retrieval of CTOP is possible with a high accuracy in most of the cases investigated. Retrieval of CGT is also possible for optically thick clouds above a black surface, at least when CGT > 1–2 km and for thin clouds for CGT > 2–3 km. However, for intermediate optical thicknesses (COT ≃ 4), we show that the retrieval of CGT is not simultaneously possible with CTOP. A comparison between 3MI and MSPI shows a higher information content for MSPI's measurements, traceable to a thinner filter inside the oxygen A-band, yielding higher signal-to-noise ratio for absorption estimation. Cases of cloud scenes above bright surfaces are more complex but it is shown that the retrieval of CTOP remains possible in almost all situations while the information content on CGT appears to be insufficient in many cases, particularly for COT < 4 and CGT < 2–3 km.


Author(s):  
Mourad Miled ◽  
Bahman Soheilian ◽  
Emmanuel Habets ◽  
Bruno Vallet

This paper proposes an hybrid online calibration method for a laser scanner mounted on a mobile platform also equipped with an imaging system. The method relies on finding the calibration parameters that best align the acquired points cloud to the images. The quality of this intermodal alignment is measured by Mutual information between image luminance and points reflectance. The main advantage and motivation is ensuring pixel accurate alignment of images and point clouds acquired simultaneously, but it is also much more flexible than traditional laser calibration methods.


Author(s):  
Liming Tao ◽  
Renbo Xia ◽  
Jibin Zhao ◽  
Tao Zhang ◽  
Yueling Chen ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document