Procedural wound geometry and blood flow generation for medical training simulators

2012 ◽  
Author(s):  
Rifat Aras ◽  
Yuzhong Shen ◽  
Jiang Li
2003 ◽  
Vol 9 (3) ◽  
pp. 183-188 ◽  
Author(s):  
Gardar Sigurdsson ◽  
Demetris Yannopoulos ◽  
Scott H. McKnite ◽  
Keith G. Lurie

2019 ◽  
Vol 9 (3) ◽  
pp. 379 ◽  
Author(s):  
Dongjin Huang ◽  
Pengbin Tang ◽  
Wen Tang ◽  
Tao Wan

Angiography is a minimally invasive diagnostic procedure in endovascular interventions. Training interventional procedures is a big challenge, due to the complexity of the procedures with the changes of measurement and visualization in blood flow rate, volume, and image contrast. In this paper, we present a novel virtual reality-based 3D interactive training platform for angiography procedure training. We propose a multi-fluid flow approach with a novel corresponding non-slip boundary condition to simulate the effect of diffusion between the blood and contrast media. A novel syringe device tool is also designed as an add-on hardware to the 3D software simulation system to model haptics through real physical interactions to enhance the realism of the simulation-based training. Experimental results show that the system can simulate realistic blood flow in complex blood vessel structures. The results are validated by visual comparisons between real angiography images and simulations. By combining the proposed software and hardware, our system is applicable and scalable to many interventional radiology procedures. Finally, we have tested the system with clinicians to assess its efficacy for virtual reality-based medical training.


Author(s):  
John L. Beggs ◽  
Peter C. Johnson ◽  
Astrid G. Olafsen ◽  
C. Jane Watkins

The blood supply (vasa nervorum) to peripheral nerves is composed of an interconnected dual circulation. The endoneurium of nerve fascicles is maintained by the intrinsic circulation which is composed of microvessels primarily of capillary caliber. Transperineurial arterioles link the intrinsic circulation with the extrinsic arterial supply located in the epineurium. Blood flow in the vasa nervorum is neurogenically influenced (1,2). Although a recent hypothesis proposes that endoneurial blood flow is controlled by the action of autonomic nerve fibers associated with epineurial arterioles (2), our recent studies (3) show that in addition to epineurial arterioles other segments of the vasa nervorum are also innervated. In this study, we examine blood vessels of the endoneurium for possible innervation.


Author(s):  
E.J. Prendiville ◽  
S. Laliberté Verdon ◽  
K. E. Gould ◽  
K. Ramberg ◽  
R. J. Connolly ◽  
...  

Endothelial cell (EC) seeding is postulated as a mechanism of improving patency in small caliber vascular grafts. However the majority of seeded EC are lost within 24 hours of restoration of blood flow in previous canine studies . We postulate that the cells have insufficient time to fully develop their attachment to the graft surface prior to exposure to hemodynamic stress. We allowed EC to incubate on fibronectin-coated ePTFE grafts for four different time periods after seeding and measured EC retention after perfusion in a canine ex vivo shunt circuit.Autologous canine EC, were enzymatically harvested, grown to confluence, and labeled with 30 μCi 111 Indium-oxine/80 cm 2 flask. Four groups of 5 cm x 4 mm ID ePTFE vascular prostheses were coated with 1.5 μg/cm.2 human fibronectin, and seeded with 1.5 x 105 EC/ cm.2. After seeding grafts in Group 1 were incubated in complete growth medium for 90 minutes, Group 2 were incubated for 24 hours, Group 3 for 72 hours and Group 4 for 6 days. Grafts were then placed in the canine ex vivo circuit, constructed between femoral artery and vein, and subjected to blood flow of 75 ml per minute for 6 hours. Continuous counting of γ-activity was made possible by placing the seeded graft inside the γ-counter detection crystal for the duration of perfusion. EC retention data after 30 minutes, 2 hours and 6 hours of flow are shown in the table.


Author(s):  
Enrico D.F. Motti ◽  
Hans-Georg Imhof ◽  
Gazi M. Yasargil

Physiologists have devoted most attention in the cerebrovascular tree to the arterial side of the circulation which has been subdivided in three levels: 1) major brain arteries which keep microcirculation constant despite changes in perfusion pressure; 2) pial arteries supposed to be effectors regulating microcirculation; 3) intracerebral arteries supposed to be deprived of active cerebral blood flow regulating devices.The morphological search for microvascular effectors in the cerebrovascular bed has been elusive. The opaque substance of the brain confines in vivo investigation to the superficial pial arteries. Most morphologists had to limit their observation to the random occurrence of a favorable site in the practically two-dimensional thickness of diaphanized histological sections. It is then not surprising most investigators of the cerebral microcirculation refer to an homogeneous network of microvessels interposed between arterioles and venules.We have taken advantage of the excellent depth of focus afforded by the scanning electron microscope (SEM) to investigate corrosion casts obtained injecting a range of experimental animals with a modified Batson's acrylic mixture.


1998 ◽  
Vol 41 (3) ◽  
pp. 538-548 ◽  
Author(s):  
Sean C. Huckins ◽  
Christopher W. Turner ◽  
Karen A. Doherty ◽  
Michael M. Fonte ◽  
Nikolaus M. Szeverenyi

Functional Magnetic Resonance Imaging (fMRI) holds exciting potential as a research and clinical tool for exploring the human auditory system. This noninvasive technique allows the measurement of discrete changes in cerebral cortical blood flow in response to sensory stimuli, allowing determination of precise neuroanatomical locations of the underlying brain parenchymal activity. Application of fMRI in auditory research, however, has been limited. One problem is that fMRI utilizing echo-planar imaging technology (EPI) generates intense noise that could potentially affect the results of auditory experiments. Also, issues relating to the reliability of fMRI for listeners with normal hearing need to be resolved before this technique can be used to study listeners with hearing loss. This preliminary study examines the feasibility of using fMRI in auditory research by performing a simple set of experiments to test the reliability of scanning parameters that use a high resolution and high signal-to-noise ratio unlike that presently reported in the literature. We used consonant-vowel (CV) speech stimuli to investigate whether or not we could observe reproducible and consistent changes in cortical blood flow in listeners during a single scanning session, across more than one scanning session, and in more than one listener. In addition, we wanted to determine if there were differences between CV speech and nonspeech complex stimuli across listeners. Our study shows reproducibility within and across listeners for CV speech stimuli. Results were reproducible for CV speech stimuli within fMRI scanning sessions for 5 out of 9 listeners and were reproducible for 6 out of 8 listeners across fMRI scanning sessions. Results of nonspeech complex stimuli across listeners showed activity in 4 out of 9 individuals tested.