Measurement of acoustic dissipation occurring in narrow channels with wet wall

2019 ◽  
Vol 145 (1) ◽  
pp. 71-76 ◽  
Author(s):  
Yuki Ueda ◽  
Naoyuki Ogura
Author(s):  
Ashish Singla ◽  
Jyotindra Narayan ◽  
Himanshu Arora

In this paper, an attempt has been made to investigate the potential of redundant manipulators, while tracking trajectories in narrow channels. The behavior of redundant manipulators is important in many challenging applications like under-water welding in narrow tanks, checking the blockage in sewerage pipes, performing a laparoscopy operation etc. To demonstrate this snake-like behavior, redundancy resolution scheme is utilized using two different approaches. The first approach is based on the concept of task priority, where a given task is split and prioritize into several subtasks like singularity avoidance, obstacle avoidance, torque minimization, and position preference over orientation etc. The second approach is based on Adaptive Neuro Fuzzy Inference System (ANFIS), where the training is provided through given datasets and the results are back-propagated using augmentation of neural networks with fuzzy logics. Three case studies are considered in this work to demonstrate the redundancy resolution of serial manipulators. The first case study of 3-link manipulator is attempted with both the approaches, where the objective is to track the desired trajectory while avoiding multiple obstacles. The second case study of 7-link manipulator, tracking trajectory in a narrow channel, is investigated using the concept of task priority. The realistic application of minimum-invasive surgery (MIS) based trajectory tracking is considered as the third case study, which is attempted using ANFIS approach. The 5-link spatial redundant manipulator, also known as a patient-side manipulator being developed at CSIR-CSIO, Chandigarh is used to track the desired surgical cuts. Through the three case studies, it is well demonstrated that both the approaches are giving satisfactory results.


2019 ◽  
Vol 4 (10) ◽  
Author(s):  
Daniel Martínez-Ruiz ◽  
Fernando Veiga-López ◽  
Mario Sánchez-Sanz

1999 ◽  
Vol 600 ◽  
Author(s):  
K. Oguro ◽  
K. Asaka ◽  
N. Fujiwara ◽  
K. Onishi ◽  
S. Sewa

AbstractComposites of perfluorinated polymer electrolyte membrane and gold electrodes bend in response to low-voltage electric stimuli and work as soft actuators like muscles. The composites were prepared by chemical plating. Charge on the electrode induces electric double layer and electro-osmotic drag of water by cation from anode to cathode through narrow channels in the perfluorinated ion-exchange resin. The electro-osmotic flow of water swells the polymer near the cathode rather than anode, and the membrane bends to the anode. The actuator comprises polymer electrolyte, electrodes, counter ion, solvent, lead wires, etc. Each component affects the performance of the actuator. Surface area of electrode and species of counter ion have drastic effect on voltage-displacement response. The response may depend on water channel structure of the polymer electrolyte. Modification of these factors improved the performance and resulted in the deflection over 360 degrees at a film actuator of 10 mm length. A tubular actuator was demonstrated as a multidirectional actuator. These actuators are applicable to artificial muscle, micro robots, or micro medical equipment inside body.


1998 ◽  
Vol 35 (9) ◽  
pp. 671-678 ◽  
Author(s):  
Md. Shafiqul ISLAM ◽  
Ryutaro HINO ◽  
Katsuhiro HAGA ◽  
Masanori MONDE ◽  
Yukio SUDO

2010 ◽  
Vol 82 (3) ◽  
Author(s):  
A. Pototsky ◽  
A. J. Archer ◽  
M. Bestehorn ◽  
D. Merkt ◽  
S. Savel’ev ◽  
...  
Keyword(s):  

Author(s):  
Yasuhisa Shinmoto ◽  
Shinichi Miura ◽  
Koichi Suzuki ◽  
Yoshiyuki Abe ◽  
Haruhiko Ohta

Recent development in electronic devices with increased heat dissipation requires severe cooling conditions and an efficient method for heat removal is needed for the cooling under high heat flux conditions. Most researches are concentrated on small semiconductors with high heat flux density, while almost no existing researches concerning the cooling of a large semiconductor, i.e. power electronics, with high heat generation density from a large cooling area. A narrow channel between parallel plates is one of ideal structures for the application of boiling phenomena which uses the cooling for such large semiconductors. To develop high-performance cooling systems for power electronics, experiments on increase in critical heat flux (CHF) for flow boiling in narrow channels by improved liquid supply was conducted. To realize the cooling of large areas at extremely high heat flux under the conditions for a minimum gap size and a minimum flow rate of liquid supplied, the structure with auxiliary liquid supply was devised to prevent the extension of dry-patches underneath flattened bubbles generated in a narrow channel. The heating surface was experimented in two channels with different dimensions. The heating surfaces have the width of 30mm and the lengths of 50mm and 150mm in the flow direction. A large width of actual power electronics is realizable by the parallel installation of the same channel structure in the transverse direction. The cooling liquid is additionally supplied via sintered metal plates from the auxiliary unheated channels located at sides or behind the main heated channel. To supply the liquid to the entire heating surface, fine grooves are machined on the heating surface for enhance the spontaneous liquid supply by the aid of capillary force. The gap size of narrow channels are varied as 0.7mm, 2mm and 5mm. Distribution of liquid flow rate to the main heated channel and the auxiliary unheated channels were varied to investigate its effect on the critical heat flux. Test liquids employed are R113, FC72 and water. The systematic experiments by using water as a test liquid were conducted. Critical heat flux values larger than 2×106W/m2 were obtained at both gap sizes of 2mm and 5mm for a heated length of 150mm. A very high heat transfer coefficient as much as 1×105W/m2K was obtained at very high heat flux near CHF for the gap size of 2mm. This paper is a summary of experimental results obtained in the past by the present authors.


Sign in / Sign up

Export Citation Format

Share Document