scholarly journals Evaluation of the Partec Flow Cytometer against the BD FACSCalibur System for Monitoring Immune Responses of Human Immunodeficiency Virus-Infected Patients in Zimbabwe

2007 ◽  
Vol 14 (3) ◽  
pp. 293-298 ◽  
Author(s):  
Justen Manasa ◽  
Hazvineyi Musabaike ◽  
Collen Masimirembwa ◽  
Eileen Burke ◽  
Ruedi Luthy ◽  
...  

ABSTRACT A single-platform volumetric flow cytometer, the Partec Cyflow SL_3, was evaluated against a BD FACSCalibur/Sysmex XT1800i dual platform for measuring CD4+ lymphocytes, total lymphocytes, and the percentage of CD4 lymphocytes in whole-blood samples for monitoring the immune systems of human immunodeficiency virus (HIV)/AIDS patients. Statistical analyses for precision, correlation, and agreement were performed. Coefficients of variation (CV) of 5.8, 4.6, and 3.9% were obtained for low, medium, and high CD4+ cell counts, respectively, using the SL_3, and CV of 3.7, 4.0, and 0.94 were obtained for the same categories, using the BD FACSCalibur. Significant correlations (P < 0.005) between the two assays for CD4 counts, total lymphocyte counts, and percentages of CD4 were obtained, with correlation coefficients of 0.99, 0.96, and 0.99, respectively (n = 229). Using the Bland-Altman plot, mean biases of −18 cell/μl (95% confidence interval (CI); −91 to 54 cells/μl), −0.8% (95% CI; −3.6 to 2%), and −36.8 cells/μl (95% CI; −477 to 404 cells/μl) were obtained for comparisons of CD4 counts, percentages of CD4 cells, and total lymphocyte counts, respectively. The effects of the age of the samples on the three parameters were also analyzed by comparing results from the same samples analyzed at 6, 24, and 48 h after collection. The correlation coefficients for comparisons among different time points for the same machine and among all the time points for the two different machines were greater than 0.90. These data showed that the Partec Cyflow SL_3 assay is comparable to the BD FACSCalibur/Sysmex XT1800i dual-platform method for measuring the amount of CD4+ cells and total lymphocytes and the percentages of CD4 cells in blood samples for the purpose of monitoring HIV/AIDS patients.

2020 ◽  
Vol 0 ◽  
pp. 1-8
Author(s):  
Tejas Kanthrao Mankeshwar ◽  
Ashok Kumar Sharma

Objectives: Abdominal pathologies are the second most common after pulmonary diseases in human immunodeficiency virus/acquired immunodeficiency syndrome (HIV/AIDS) patients. Ultrasonography (USG) is a vital imaging technique for the evaluation of abdominal pathologies. This study was aimed at evaluating the abdominal pathologies using USG in HIV/AIDS and further analysis of its correlation with CD4 count. Material and Methods: The present study was carried out on 392 HIV-positive patients with abnormal abdominal sonographic findings. All data were analyzed by Chi-square test and one-way analysis of variance using SPSS 16.0 software. Results: Of these 392 patients, 66.3% were males, the mean age was 35.7 years, (range 7–64 years) and most of them were in 4th decade. On ultrasonographic evaluation, spleen was involved in 45.2% patients and liver as well as lymph nodes each was involved in 43.6% patients. Other cases displayed ascites and bowel thickening in 5.3% and 3.8% patients, respectively. Less involvement of kidney (2.3%), pancreas (1.5%), and biliary system (1.3%) was observed. In addition, pathologies such as hepatomegaly, splenomegaly, splenic microabscess, focal pancreatic lesion, mesenteric, and periportal lymphadenopathy showed significant correlation with CD4 counts. Lymphoma was found in 1% of patients, involving liver, pancreas, and retroperitoneal lymph nodes. Conclusion: Our study highlights the clinical utility of abdominal USG in HIV/AIDS patients. CD4 counts largely affect the differential diagnosis in HIV/AIDS patients. USG findings interpreted in the context of CD4 count may help in guiding the exact diagnosis.


2003 ◽  
Vol 71 (11) ◽  
pp. 6668-6671 ◽  
Author(s):  
W. Evan Secor ◽  
Amil Shah ◽  
Pauline M. N. Mwinzi ◽  
Bryson A. Ndenga ◽  
Caroline O. Watta ◽  
...  

ABSTRACT Distribution of chemokine receptors CCR5 and CXCR4, which are also coreceptors for human immunodeficiency virus type 1 invasion of cells, was measured on the surfaces of CD4+ T cells and monocytes in peripheral blood samples from a group of Kenyan car washers. Patients with active schistosomiasis displayed higher cell surface densities of these receptors than did cured schistosomiasis patients.


2005 ◽  
Vol 12 (12) ◽  
pp. 1416-1424 ◽  
Author(s):  
Kovit Pattanapanyasat ◽  
Surada Lerdwana ◽  
Egarit Noulsri ◽  
Thanyanan Chaowanachan ◽  
Punneeporn Wasinrapee ◽  
...  

ABSTRACT Use of the standard dual-platform flow cytometric method for determination of CD4+ T-lymphocyte counts, which needs both a flow cytometer (FCM) and hematological analyzer, would inevitably lead to increased variability. The development of new single-platform (SP) FCMs that provide direct CD4+ T-lymphocyte counts for improved assay precision and accuracy have recently attracted attention. This study evaluated one of those systems, CyFlowgreen (Partec), a single-parameter SP volumetric FCM. The performance of CyFlowgreen was compared with those of two reference standard SP microbead-based technologies of the three-color TruCOUNT tube with the FACScan FCM and a two-color FACSCount system (Becton Dickinson Biosciences). Absolute CD4+ and CD8+ T-lymphocyte counts in 200 human immunodeficiency virus type 1-seropositive blood specimens were determined. Statistical analysis for correlation and agreement were performed. A high correlation of absolute CD4 counts was shown when those obtained with CyFlowgreen were compared with those obtained with the bead-based three-color TruCOUNT system (R 2 = 0.96; mean bias, −69.1 cells/μl; 95% confidence interval [CI], −225.7 to +87.5 cells/μl) and the FACSCount system (R 2 = 0.97; mean bias, −40.0 cells/μl; 95% CI, −165.1 to +85.1 cells/μl). The correlation of the CD4+ T-lymphocyte counts obtained by the two bead-based systems was high (R 2 = 0.98). Interestingly, CyFlowgreen yielded CD4+ T-lymphocyte counts that were 21.8 and 7.2 cells/μl lower than those obtained with the TruCOUNT and the FACSCount systems, respectively, when CD4+ T-lymphocyte counts were <250 CD4+ T-lymphocyte counts/μl range or 17.3 and 5.8 cells/μl less, respectively, when CD4+ T-lymphocyte counts were <200 cells/μl. The single-parameter CyFlowgreen volumetric technology performed well in comparison with the performance of the standard SP bead-based FCM system. However, a multicenter comparative study is needed before this FCM machine is implemented in resource-limited settings.


2000 ◽  
Vol 182 (4) ◽  
pp. 1070-1076 ◽  
Author(s):  
Mark A. Jacobson ◽  
David Hardy ◽  
Elizabeth Connick ◽  
Jessica Watson ◽  
Michael DeBruin

Author(s):  
Sadia Salahuddin ◽  
Joharia Azhar ◽  
Hasham Akhtar ◽  
Jabbar Khan ◽  
Noor Muhammad

Abstract Objectives: To molecularly characterise the relationship between Epstein-Barr virus genotypes and Pashtun ethnicity. Method: The cross-sectional study was conducted from November 2018 to December 2019 after approval from the Gomal University, Dera Ismail Khan, Pakistan, and comprised blood samples from transgender sex workers who were seropositive for human immunodeficiency virus-1 and seronegative for human immunodeficiency virus residing in two cities of Khyber Pakhtunkhwa province and Islamabad, the federal capital. Formalin-fixed paraffin-embedded samples were collected retrospectively, but collection of blood samples from the study subjects was purely on the basis of physical availability. ?-globin gene and EBER-1 were amplified for qualitative assessment and existence of Epstein-Barr virus. Characterisation of EBNA-2 was done through nested polymerase chain reaction. Results: Of the 80 subjects, 40(50%) each were seropositive and seronegative individuals. The overall mean age was 28±6.917 years. Among the seropositive group, 38(95%) were homosexual and 2(5%) were heterosexual. Among the seropositive group, 16(40%) had Epstein-Barr virus genotype 1 and 6(15%) had genotype 2, while co-infections were found in 2(5%) subjects. In the seronegative group, 36(90%) subjects had Epstein-Barr virus genotype 1, while there was no case of genotype 2 or co-infection. EBV-2 genotypes with HIV seropositivity showed strong association (p=0.005). Amplification for the EBER-1 gene was done in all the 80(100%) samples. Conclusion: Epstein-Barr virus EBV genotype 1 was found to be the most frequent type, while genotype 2 and co-infections were detected only seropositive samples. Continuous...


Sign in / Sign up

Export Citation Format

Share Document