A Cryomagnetic System with Superconducting Windings for a Magnetic Separator

2021 ◽  
Vol 64 (6) ◽  
pp. 917-920
Author(s):  
D. V. Varyukhin ◽  
N. V. Taryanik ◽  
P. N. Postol ◽  
D. O. Fedyuk
Keyword(s):  
2019 ◽  
Vol 13 (1) ◽  
pp. 137-145 ◽  
Author(s):  
Tzonka Godjevargova ◽  
Zlatina Becheva ◽  
Yavor Ivanov ◽  
Andrey Tchorbanov

Objectives: Staphylococcus aureus is a Gram-positive microorganism. S. aureus can grow in various foods and cause food poisoning by secreting enterotoxins. The most common enterotoxins involved in food poisoning are staphylococcal enterotoxin A and staphylococcal enterotoxin B, but Staphylococcal Enterotoxin A (SEA) is predominant. The main types of food contaminated with SEs are meat and meat products, poultry and eggs, milk and dairy products. The aim of this study was to develop a rapid and sensitive fluorescence immunoassay for detection of staphylococcal enterotoxin A in milk. Methods: Monoclonal and polyclonal antibodies for SEA were produced and characterized. Competitive fluorescence immunoassay based on Magnetic Nanoparticles (MNPs) was performed and optimized. MNPs were used as a solid carrier of the antibodies. The first step of the assay was immunoreaction between the immobilized antibody onto MNPs and SEA in milk sample. Then the fluorescein-SEA conjugate was added to the sample. Thus, competitive immunoreaction between MNP-mAb/MNP-pAb with SEA and SEA-FITC was performed. These immuno-complexes were separated by a magnetic separator and the obtained supernatants were analyzed. The fluorescent signal from the excess of conjugated SEA was proportional to the SEA contained in the milk. The assay duration was only 30 min. Results: The fluorescence immunoassays performed with polyclonal antibody had linear ranges from 5 pg/mL to 100 ng/mL SEA in a buffer, and from 50 pg/mL to 50 ng/mL SEA in spiked milk samples. While the same assays performed with monoclonal antibody had linear ranges from 1 pg/mL to 20 ng/mL SEA in buffer, and from 10 pg/mL to 10 ng/mL SEA in spiked milk samples. The detection limits of the developed immunoassays performed in milk were: 48 pg/mL with polyclonal antibody and 9 pg/mL with monoclonal antibody. Conclusion: A rapid and sensitive fluorescence immunoassay based on magnetic nanoparticles with a polyclonal and monoclonal antibody for determination of staphylococcal enterotoxin A in milk was developed.


2019 ◽  
Vol 116 (3) ◽  
pp. 324 ◽  
Author(s):  
Kuranga Ibrahim Ayinla ◽  
Alafara Abdullahi Baba ◽  
Bankim Chandra Tripathy ◽  
Malay Kumar Ghosh ◽  
Rajan Kumar Dwari ◽  
...  

This study, focused on the beneficiation of a Nigerian complex chromite ore sourced from Tunga-Kaduka, Anka Local Government of Zamfara State, Nigeria, assaying 45.85% Cr2O4 and 54.15% mineral impurities, was enriched concurrently through sink floatation and magnetic separation techniques. The chromite ore initially analyzed to contain silicate impurities was found not suitable for metallurgical purposes. Thus, enrichment was examined through gravity separation studies using organic liquid with different specific gravities at 2.8, 3.3, and 4.0. The separation of chromite ore with lowest particle size fraction was done using Mozley mineral separator followed by the magnetic separation of the sink product by magnetic separator. The results obtained revealed about 77% of the total material containing 300 μm particle size, 52% ˂ 212 μm and 17% below 75 μm. Subsequent analysis of the beneficiated ore was carried out by wet chemical analysis and atomic absorption spectrophotometer. The results showed that Cr2O4 content increased to 78.34% from initial 45.83% with maximum Cr:Fe ratio of 3.2:1, representing 84.27% of chromium metal present in the ore. The enrichment of Cr2O4 obtained in this study could be found metallurgically applicable in the electro-deposition and ferro-chromium alloy production practices.


2003 ◽  
Vol 12 (1) ◽  
pp. 13-22 ◽  
Author(s):  
W. A. P. J. Premaratne ◽  
N. A. Rowson

An investigation has been carried out to study the mineralogical and chemical characteristics of beach sand deposits from Sri Lanka and application and optimisation of different magnetic separators (induced roll magnetic separator and disc magnetic separator) to improve the recovery of titanium from the deposit. Commercial grade titanium concentrates could be achieved employing both induced roll and disc magnetic separators. However, the titanium recovery increased greatly in the magnetic fraction with a titanium content of commercial grade (up to 63.9% TiO2) when paramagnetic titanium-bearing minerals were separated from beach sand using the disc magnetic separator. The results of the mineralogical and chemical analysis tests for the beach sand deposit indicated that 71% of beach sand was smaller than 355 μm in particle size and more than 99% of titanium content of the deposit was contained in this fraction.


2016 ◽  
Vol 77 ◽  
pp. 1183-1191 ◽  
Author(s):  
Chengquan Wang ◽  
Jing Qian ◽  
Kun Wang ◽  
Xingwang Yang ◽  
Qian Liu ◽  
...  

1985 ◽  
Vol 1 (4) ◽  
pp. 185-194
Author(s):  
E. A. Mendrela ◽  
K. Adamiak ◽  
E. M. Mendrela

The construction and principle of operation of a new magnetic separator for volatile dust is described. The results, obtained on a model separator in laboratory conditions are discussed.


Sign in / Sign up

Export Citation Format

Share Document