The sensitivity and specificity of TOF-MRA compared with DSA in the follow-up of treated intracranial aneurysms

2021 ◽  
pp. neurintsurg-2020-016788
Author(s):  
Sishi Xiang ◽  
Fu Fan ◽  
Peng Hu ◽  
Kun Yang ◽  
Xiaodong Zhai ◽  
...  

BackgroundTime-of-flight magnetic resonance angiography (TOF-MRA) is widely used in detecting intracranial aneurysms (IA), but it is limited and controversial for use during follow-up to assess the outcome of interventional coiling or clipping surgery.MethodsTo evaluate the specificity and sensitivity of using TOF-MRA as an imaging follow-up for IA with different treatments. A total of 280 patients with 326 treated IA underwent simultaneous TOF-MRA and digital subtraction angiography (DSA) as follow-up imaging on the same day. All images were independently reviewed by two neurosurgeons and two radiologists. The consensus evaluation of intra-arterial DSA as a reference test was used to evaluate the result of aneurysm occlusions. The aneurysmal embolization status was assessed with two ratings involving complete or incomplete occlusions. We calculated the sensitivity, specificity, negative predictive value, and positive predictive value of three-dimensional-TOF-MRA to investigate the diagnostic performance.ResultsOverall sensitivity and specificity of TOF-MRA for diagnosing the remnant were 83.3% and 95.2%, respectively. The sensitivity and specificity of interventional therapy was 90.0% and 94.2%, respectively, while the clipping group showed sensitivity and specificity of 50.0% and 100%, respectively. For additional groups, involving coil only, stent-assisted, and flow diverter, the analysis of interventional therapy showed sensitivities and specificities of 100.0% and 90.1%, 66.7% and 95.1%, and 91.7% and 100%, respectively.ConclusionsTOF-MRA can be used as a first-line noninvasive imaging modality during follow-up, especially for the patients treated with a pipeline embolization device and coils only. But it may not be enough for clipped aneurysms.

2021 ◽  
Vol 23 (1) ◽  
Author(s):  
Batur Halitcan ◽  
Sayin Bige ◽  
Balci Sinan ◽  
Akmangit Ilkay ◽  
Daglioglu Ergun ◽  
...  

Abstract Background Serial cerebral angiographic imaging is necessary to ensure cerebral aneurysm occlusion after flow diverter placement. Time-of-flight (TOF)-magnetic resonance angiography (MRA) is used for this purpose due to its lack of radiation, contrast media and complications. The comparative diagnostic yield of TOF-MRA for different flow diverters has not been previously analyzed. Purpose To evaluate the diagnostic accuracy of TOF-MRA in cerebral aneurysms treated w divertersith different flow diverters. Materials and Methods Flow-diverted patients whose cerebral follow-up MRA and digital subtraction angiograms (DSA) were obtained within 6 weeks were retrospectively identified. The DSA (as gold standard) and MRA images of these patients were compared by two readers (blinded to both patient data and endovascular procedure data) for residual aneurysms and the status of the parent artery for each type of flow diverter. In a second group of patients, magnetic susceptibility artifacts were manually measured and compared for different FDs. Results Seventy-six patients (85 aneurysms) were included in group one, and 86 patients (95 aneurysms) were included in group 2. TOF-MRA and DSA showed almost perfect agreement for residual aneurysms (κ = 0.88, p < 0.001) (positive predictive value (PPV) = 1.00, specificity = 1.00, negative predictive value (NPV) = 0.89, sensitivity = 0.89). Intermodality agreement (κ = 0.97 vs. κ = 0.74, p < 0.005) and sensitivity (0.97 vs. 0.77, NPV: 0.96 vs. 0.77) were highest with nitinol stents. MRA and DSA showed no agreement for occluded or stenotic parent vessels (κ = 0.13, p = 0.015, specificity = 0.44, NPV = 1.00, sensitivity = 1.00). Specificity was lower in chromium-cobalt based FDs than in nitinol devices (specificity = 0.08 vs. 0.60). Chromium-cobalt stents generated the largest artifacts (p < 0.005). The size of the device-related artifact, in millimeters, increased in respective order, for the Silk, Derivo, Pipeline and Surpass devices. Conclusion Unlike DSA, TOF-MRA is susceptible to dissimilarities between flow diverters. MRA is not well-suited for research studies comparing different flow diverters. Nitinol FDs appear to be advantageous for TOF-MRA follow-up so as not to miss small aneurysm remnants or clinically relevant parent artery stenosis.


2014 ◽  
Vol 8 (1) ◽  
pp. 81-86 ◽  
Author(s):  
Jonathan Attali ◽  
Azzedine Benaissa ◽  
Sébastien Soize ◽  
Krzysztof Kadziolka ◽  
Christophe Portefaix ◽  
...  

Background and purposeFollow-up of intracranial aneurysms treated by flow diverter with MRI is complicated by imaging artifacts produced by these devices. This study compares the diagnostic accuracy of three-dimensional time-of-flight MR angiography (3D-TOF-MRA) and contrast-enhanced MRA (CE-MRA) at 3 T for the evaluation of aneurysm occlusion and parent artery patency after flow diversion treatment, with digital subtraction angiography (DSA) as the gold standard.Materials and methodsPatients treated with flow diverters between January 2009 and January 2013 followed by MRA at 3 T (3D-TOF-MRA and CE-MRA) and DSA within a 48 h period were included in a prospective single-center study. Aneurysm occlusion was assessed with full and simplified Montreal scales and parent artery patency with three-grade and two-grade scales.ResultsTwenty-two patients harboring 23 treated aneurysms were included. Interobserver agreement using simplified scales for occlusion (Montreal) and parent artery patency were higher for DSA (0.88 and 0.61) and CE-MRA (0.74 and 0.55) than for 3D-TOF-MRA (0.51 and 0.02). Intermodality agreement was higher for CE-MRA (0.88 and 0.32) than for 3D-TOF-MRA (0.59 and 0.11). CE-MRA yielded better accuracy than 3D-TOF-MRA for aneurysm remnant detection (sensitivity 83% vs 50%; specificity 100% vs 100%) and for the status of the parent artery (specificity 63% vs 32%; sensitivity 100% vs 100%).ConclusionsAt 3 T, CE-MRA is superior to 3D-TOF-MRA for the evaluation of aneurysm occlusion and parent artery patency after flow diversion treatment. However, intraluminal evaluation remains difficult with MRA regardless of the sequence used.


2014 ◽  
Vol 20 (6) ◽  
pp. 686-692 ◽  
Author(s):  
Akin Levent ◽  
Ihsan Yuce ◽  
Suat Eren ◽  
Omer Ozyigit ◽  
Mecit Kantarci

This study evaluated contrast-enhanced magnetic resonance angiography (CE-MRA) and three-dimensional time-of-flight magnetic resonance angiography (3D-TOF-MRA) through comparisons with digital subtraction angiography (DSA) for the follow-up of intracranial aneurysms treated with detachable coils. Sixty-seven patients with 79 aneurysms underwent 3D-TOF-MRA, CE-MRA, and catheter angiography one year after coiling. Two independent observers classified recanalization status on images as neck or body remnant or no recanalization. For 3D-TOF-MRA and CE-MRA, the intermodality agreement, interobserver agreement, and correlation with angiography were assessed. Sixty-seven patients with 79 coiled aneurysms agreed to participate in the study. Three aneurysms could not be detected on 3D-TOF-MRA, so they were excluded from this study. Interobserver agreement was very good for 3D-TOF-MRA and CE-MRA (kappa (κ): 0.87, 0.94, respectively). Correlation of TOF-MRA with angiography was good (κ: 0.76). Correlation of CE-MRA with angiography was excellent (κ: 0.91). The sensitivity and specificity of TOF-MRA were 92% and 98%, respectively. The sensitivity and specificity of CE-MRA were 96% and 98%, respectively. After selective embolization of intracranial aneurysms, CE-MRA is useful and comparable to DSA in the assessment of aneurysmal recanalization. Agreement with the gold standard is stronger with CE-MRA than with 3D-TOF-MRA.


2021 ◽  
pp. 159101992199050
Author(s):  
Erol Akgul ◽  
Hasan Bilen Onan ◽  
Irem Islek ◽  
Mehmet Tonge ◽  
Yavuz Durmus ◽  
...  

Background We assessed the safety and efficacy of flow diverter stents (FDSs) in the treatment of recanalized or residual intracranial aneurysms treated endovascularly. Materials & Methods Patients whose recanalized or residual aneurysms were treated with FDSs in five tertiary hospitals were reviewed retrospectively. The patients’ demographic data, aneurysm characteristics, types of previous treatment, and clinical complications, or serious adverse events associated with FDSs, as well as the results of neurological and angiographic follow-up assessments, were recorded. Results Eighty-six patients (37 males) with 87 aneurysms were included in this study. Eighty (91.9%) aneurysms were in the anterior and seven (8.1%) in the posterior circulation. The initial treatment methods were the primary coiling or balloon remodeling technique in 69 (79.3%) and stent-assisted coiling in 18 (20.7%) aneurysms. The endovascular procedure was successful in all patients. Complications occurred in four patients, for a total complication rate of 4.6%. A technical complication developed in one patient (1.2%). An in-stent thrombosis treated with tirofiban was seen in two cases. Late in-stent stenosis exceeding 50% was treated with balloon angioplasty in one patient. The mean length of follow-up was 21.0 months. The first angiographic follow-up (3–6 months) revealed the complete occlusion of 74 aneurysms (85.1%). While 76 aneurysms (87.4%) were occluded at the last angiographic follow-up (mean: 26.0 months), 11 aneurysms (12.6%) were still filling. Morbimortality was zero. Conclusion The drawback of endovascular treatment is aneurysmal remnants or recurrences, which is safely and durably amenable to flow diversion.


2021 ◽  
pp. 159101992110279
Author(s):  
Muhammad Waqas ◽  
Rimal H Dossani ◽  
Modhi Alkhaldi ◽  
Jocelyn Neveu ◽  
Justin M Cappuzzo ◽  
...  

Introduction The Flow Redirection Endoluminal Device (FRED; MicroVention) is a dual-layered flow diverter used for the treatment of intracranial aneurysms. The objective of this systematic review was to compile device-related safety and effectiveness data. Methods The literature from January 1, 2013 to April 30, 2021 was searched for studies describing use of the FRED for intracranial aneurysm treatment irrespective of aneurysm location and morphology. The review included anterior and posterior circulation ruptured and unruptured saccular, fusiform or dissection, and blister aneurysms. MeSH terms related to “flow re-direction endoluminal device” and “FRED for aneurysms” were used. Data related to indication, complications, and rates of aneurysm occlusion were retrieved and analyzed. Results Twenty-two studies with 1729 intracranial aneurysms were included in this review. Overall reported morbidity was 3.9% (range 0–20%). Overall procedure-related mortality was 1.4% (range 0–6%). Complication rates fell into 5 categories: technical (3.6%), ischemic (3.8%), thrombotic or stenotic (6%), hemorrhagic (1.5%), and non-neurological (0.8%). The aneurysm occlusion rate between 0 and 3 months (reported in 11 studies) was 47.8%. The occlusion rate between 4 and 6 months (reported in 14 studies) was 73.8%. Occlusion rates continued to increase to 75.1% at 7–12 months (reported in 10 studies) and 86.6% for follow-up beyond 1 year (reported in 10 studies). Conclusion This review indicated that the FRED is a safe and effective for the treatment of intracranial aneurysms. Future studies should directly compare the FRED with other flow diverters for a better understanding of comparative safety and effectiveness among the different devices.


Stroke ◽  
2014 ◽  
Vol 45 (suppl_1) ◽  
Author(s):  
Ajay K Wakhloo ◽  
Pedro Lylyk ◽  
Joost de Vries ◽  
Matthew J Gounis ◽  
Alexandra Biondi ◽  
...  

Objective: Validated through experimental studies a new generation of flow diverters (Surpass™ FD) was evaluated for treatment of intracranial aneurysms (IA). We present our multicenter preliminary clinical and angiographic experience. METHODS: To achieve the calculated flow disruption between the parent artery and aneurysm for thrombosis, single FDs were placed endovascularly in parent arteries. Implants measured 2.5-5.3mm in diameter with a length of 10-80mm. Patients were enrolled harboring a wide range large and giant wide-neck, fusiform and multiple small and blister-type aneurysm. Clinical and angiographic follow-up were performed at 1-3, 6, and 12 months. RESULTS: A total of 186 consecutive IA in 161 patients (mean age 57.1 years) were treated at 33 centers. Fifty-three aneurysms were smaller than 5 mm, 64 were 5-9.9mm in diameter, 47 were 10-20mm in diameter, and 22 were larger than 20mm (10.4±0.7mm, neck size 6.0±0.5mm [mean±SEM]) . The aneurysms originated in 63.4% from the internal carotid artery; 22% and 14.5% of the lesions were located in the anterior circulation distal to Circle of Willis and posterior circulation respectively. Technical success was achieved in 182 aneurysms (98%); average number of devices used per aneurysm was 1.05. Permanent morbidity and mortality during the follow-up period of mean 8.4months (range 1-24 months) including periprocedural complications for patients with aneurysms of the anterior circulation were encountered in 5 (3.7%) and 2 (1.5 %) patients respectively and 1 (3.7%) and 4 (14.8%) respectively for patients with aneurysms of the posterior circulation location. One-hundred-ten patients (70.5%) harboring 127 (70.2%) were available for clinical and angiographic follow-up and showed a complete or near complete aneurysm occlusion in 63 (81.8%) of the ICA. Aneurysms of the ICA≥10mm that were completely covered by FD and not previously stent-treated with a minimum of 6 months follow-up available in 16 patients showed a complete obliteration in 81.3% (n=13) and >90% occlusion in remaining 3 patients. CONCLUSION: Preliminary data demonstrate high safety and efficacy of a new generation of FD for a wide range of IA of the anterior and posterior circulation with a single implant.


Author(s):  
Firoozeh Ahmadi ◽  
Farnaz Akhbari ◽  
Fatemeh Niknejad ◽  
Hadieh Haghighi ◽  
Zahra Ghahremani ◽  
...  

ABSTRACT Introduction Two of the most frequent procedures performed on infertile women are two-dimensional ultrasound (2DUS) and three-dimensional ultrasound (3DUS). Hysteroscopy is considered as the gold standard for evaluation of acquired endometrial lesions in infertile women; however, 3DUS is used as a noninvasive, less expensive, and reliable assessment method for evaluation of the intrauterine lesions in infertile women. We aimed to compare the diagnostic efficiency between 3DUS and hysteroscopy in the detection of lesions (polyps, submucous leiomyoma, and synechiae) in infertile women. Materials and methods In this prospective observational study, infertile women (n = 155) with indication of hysteroscopy were scheduled to undergo 3DUS prior to hysteroscopy from September 2010 to 2011. Women with suspected congenital uterine anomalies were excluded. The sensitivity and specificity values of 3DUS were compared with those of hysteroscopy. Hysteroscopy was used as the gold standard for diagnosis of intrauterine lesions in infertile women. Results Of the 155 women, 50 were found to have an intracavitary abnormality, 36 had polyps, 12 had myomas, and 7 had synechiae on hysteroscopic findings. Examination with 3DUS in the diagnosis of intrauterine lesions reached an accuracy of 94%, and 92.15 and 96.9% of sensitivity and specificity respectively. Positive predictive value (PPV) was 83.9%, and a negative predictive value (NPV) was 91.3% (LR+ = 10.75, LR+ = 0.065). Conclusion According to our results, 3DUS has a reliable diagnostic accuracy for intrauterine lesions, and it may limit unnecessary hysteroscopy in patients with normal results. How to cite this article Ahmadi F, Haghighi H, Ghahremani Z, Niknejad F, Akhbari F, Ramezanali F, Chehrazi M. Diagnostic Accuracy of Three-dimensional Ultrasonography in Detection of Endometrial Lesions compared with Hysteroscopy in Infertile Women. Donald School J Ultrasound Obstet Gynecol 2016;10(4):393-397.


Neurosurgery ◽  
2002 ◽  
Vol 50 (3) ◽  
pp. 476-485 ◽  
Author(s):  
Hiro Kiyosue ◽  
Mika Okahara ◽  
Shuichi Tanoue ◽  
Takaharu Nakamura ◽  
Hirofumi Nagatomi ◽  
...  

Abstract OBJECTIVE: Detection of a small residual lumen after coil embolization is often difficult because of the coil mass and the overlap of the cerebral arteries. The purpose of this study was to assess the usefulness of virtual endoscopic (VE) analysis of three-dimensional digital subtraction angiographic (DSA) images for evaluation of aneurysmal occlusion immediately after the procedure. METHODS: Twenty-seven intracranial aneurysms were treated with coil embolization using a three-dimensional DSA system. Biplane and rotational DSA scanning was performed before and immediately after the procedures. VE images were obtained at a separate workstation, after transfer of the rotational images. Two-dimensional (2D) DSA images and VE images obtained after the procedure were assessed with respect to aneurysmal occlusion. Morphological outcomes and other factors, including location, size, volumetric ratio (coil volume/aneurysm volume), and residual sites, were also evaluated. RESULTS: Seven aneurysms were evaluated as complete occlusion (CO) on both 2D DSA images and VE images. Twelve aneurysms exhibited residual lumina on both 2D DSA images and VE images. Five aneurysms were evaluated as CO on 2D DSA images and as incomplete occlusion on VE images. There were no recurrences among the aneurysms that were evaluated as CO on VE images. Two of five aneurysms that were evaluated as CO on 2D DSA images and as incomplete occlusion on VE images demonstrated regrowth in follow-up examinations. Residual sites and volumetric ratios were correlated with aneurysmal regrowth. CONCLUSION: VE imaging can demonstrate a residual lumen more frequently than can 2D DSA imaging and is useful for evaluating aneurysmal occlusion after coil embolization.