scholarly journals Ground response to tunnelling incorporating soil reinforcement system

2019 ◽  
Vol 56 (11) ◽  
pp. 1719-1728
Author(s):  
Binh Thanh Le ◽  
R.N. Taylor

The forepole umbrella system (FUS) uses steel pipes installed from within a tunnel to provide a canopy above the tunnel heading that both increases stability and reduces tunnelling-induced ground movements. Although the system is known to be beneficial and has been used in a number of projects, there is little information on how key parameters including length and forepole stiffness combine to produce effective support. To investigate this, centrifuge tests incorporating the three-dimensional (3D) geometry of a tunnel heading in clay and the model FUS have been undertaken. The tunnel heading was supported by a pressurized rubber bag lining with excavation being simulated by a reduction in air support pressure. Image analysis was used to obtain subsurface ground movements and a newly developed 3D imaging system was used to measure the soil surface deformations accurately. The performance of the FUS and the influences of key FUS parameters were quantified via the settlement reduction factor. The results showed that the FUS, arranged in various settings, reduced the maximum surface settlement by 35%–75%. The effects of the FUS parameters on the reinforcing effectiveness are dependent on the ratio of cover depth to tunnel diameter. An optimum design arrangement of the FUS is suggested.

2019 ◽  
Vol 14 (1) ◽  
Author(s):  
Wu-zhou Li ◽  
Zhi-wen Liang ◽  
Yi Cao ◽  
Ting-ting Cao ◽  
Hong Quan ◽  
...  

Abstract Background Tumor motion may compromise the accuracy of liver stereotactic radiotherapy. In order to carry out a precise planning, estimating liver tumor motion during radiotherapy has received a lot of attention. Previous approach may have difficult to deal with image data corrupted by noise. The iterative closest point (ICP) algorithm is widely used for estimating the rigid registration of three-dimensional point sets when these data were dense or corrupted. In the light of this, our study estimated the three-dimensional (3D) rigid motion of liver tumors during stereotactic liver radiotherapy using reconstructed 3D coordinates of fiducials based on the ICP algorithm. Methods Four hundred ninety-five pairs of orthogonal kilovoltage (KV) images from the CyberKnife stereo imaging system for 12 patients were used in this study. For each pair of images, the 3D coordinates of fiducial markers inside the liver were calculated via geometric derivations. The 3D coordinates were used to calculate the real-time translational and rotational motion of liver tumors around three axes via an ICP algorithm. The residual error was also investigated both with and without rotational correction. Results The translational shifts of liver tumors in left-right (LR), anterior-posterior (AP),and superior-inferior (SI) directions were 2.92 ± 1.98 mm, 5.54 ± 3.12 mm, and 16.22 ± 5.86 mm, respectively; the rotational angles in left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions were 3.95° ± 3.08°, 4.93° ± 2.90°, and 4.09° ± 1.99°, respectively. Rotational correction decreased 3D fiducial displacement from 1.19 ± 0.35 mm to 0.65 ± 0.24 mm (P<0.001). Conclusions The maximum translational movement occurred in the SI direction. Rotational correction decreased fiducial displacements and increased tumor tracking accuracy.


Sensors ◽  
2021 ◽  
Vol 21 (8) ◽  
pp. 2858
Author(s):  
Kelly Ka-Lee Lai ◽  
Timothy Tin-Yan Lee ◽  
Michael Ka-Shing Lee ◽  
Joseph Chi-Ho Hui ◽  
Yong-Ping Zheng

To diagnose scoliosis, the standing radiograph with Cobb’s method is the gold standard for clinical practice. Recently, three-dimensional (3D) ultrasound imaging, which is radiation-free and inexpensive, has been demonstrated to be reliable for the assessment of scoliosis and validated by several groups. A portable 3D ultrasound system for scoliosis assessment is very much demanded, as it can further extend its potential applications for scoliosis screening, diagnosis, monitoring, treatment outcome measurement, and progress prediction. The aim of this study was to investigate the reliability of a newly developed portable 3D ultrasound imaging system, Scolioscan Air, for scoliosis assessment using coronal images it generated. The system was comprised of a handheld probe and tablet PC linking with a USB cable, and the probe further included a palm-sized ultrasound module together with a low-profile optical spatial sensor. A plastic phantom with three different angle structures built-in was used to evaluate the accuracy of measurement by positioning in 10 different orientations. Then, 19 volunteers with scoliosis (13F and 6M; Age: 13.6 ± 3.2 years) with different severity of scoliosis were assessed. Each subject underwent scanning by a commercially available 3D ultrasound imaging system, Scolioscan, and the portable 3D ultrasound imaging system, with the same posture on the same date. The spinal process angles (SPA) were measured in the coronal images formed by both systems and compared with each other. The angle phantom measurement showed the measured angles well agreed with the designed values, 59.7 ± 2.9 vs. 60 degrees, 40.8 ± 1.9 vs. 40 degrees, and 20.9 ± 2.1 vs. 20 degrees. For the subject tests, results demonstrated that there was a very good agreement between the angles obtained by the two systems, with a strong correlation (R2 = 0.78) for the 29 curves measured. The absolute difference between the two data sets was 2.9 ± 1.8 degrees. In addition, there was a small mean difference of 1.2 degrees, and the differences were symmetrically distributed around the mean difference according to the Bland–Altman test. Scolioscan Air was sufficiently comparable to Scolioscan in scoliosis assessment, overcoming the space limitation of Scolioscan and thus providing wider applications. Further studies involving a larger number of subjects are worthwhile to demonstrate its potential clinical values for the management of scoliosis.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Angika Bulbul ◽  
Joseph Rosen

AbstractPartial aperture imaging system (PAIS) is a recently developed concept in which the traditional disc-shaped aperture is replaced by an aperture with a much smaller area and yet its imaging capabilities are comparable to the full aperture systems. Recently PAIS was demonstrated as an indirect incoherent digital three-dimensional imaging technique. Later it was successfully implemented in the study of the synthetic marginal aperture with revolving telescopes (SMART) to provide superresolution with subaperture area that was less than one percent of the area of the full synthetic disc-shaped aperture. In the study of SMART, the concept of PAIS was tested by placing eight coded phase reflectors along the boundary of the full synthetic aperture. In the current study, various improvements of PAIS are tested and its performance is compared with the other equivalent systems. Among the structural changes, we test ring-shaped eight coded phase subapertures with the same area as of the previous circular subapertures, distributed along the boundary of the full disc-shaped aperture. Another change in the current system is the use of coded phase mask with a point response of a sparse dot pattern. The third change is in the reconstruction process in which a nonlinear correlation with optimal parameters is implemented. With the improved image quality, the modified-PAIS can save weight and cost of imaging devices in general and of space telescopes in particular. Experimental results with reflective objects show that the concept of coded aperture extends the limits of classical imaging.


Géotechnique ◽  
2021 ◽  
pp. 1-41
Author(s):  
Mohammad Hassan Baziar ◽  
Alireza Ghadamgahi ◽  
Andrew John Brennan

Seismic design of soil-nailed walls requires demonstrations of tolerable ranges of wall movements, especially when a surcharge load exists near the wall. In this study, the effect of surcharge location on seismically induced wall movements was investigated using four centrifuge tests. The axial tensile forces, developed along the soil nails during the seismic loadings, were also measured during the tests. At 50g centrifugal acceleration, model tests represented a 12-m-high prototype wall reinforced with five rows of soil nails. To apply a surcharge stress of 30 kPa at the specified location relative to the wall for each model test, a rigid footing was placed on the soil surface. The model soil-nailed walls were subjected to three successive earthquake motions. Surprisingly, it was found that the model wall with the footing located behind the soil-nailed region experienced the largest seismic movements, even more than when the footing was directly behind the wall. Further, the tests showed that the lower soil nails played a key role in the wall stability during earthquake shaking, acting as a pivot for the pre-collapse cases tested, whereas the upper soil nails needed to be sufficiently extended to properly contribute to the seismic stability of the wall.


Sign in / Sign up

Export Citation Format

Share Document