CALIBRATION AND CHARACTERISTICS OF A SENSITIVE HOT-WIRE ANEMOMETER

1945 ◽  
Vol 23f (3) ◽  
pp. 192-197
Author(s):  
T. A. Steeves ◽  
A. E. Chadderton ◽  
W. H. Cook
Keyword(s):  
Air Flow ◽  
Hot Wire ◽  

A wet test meter was used to measure the air supplied to a small wind tunnel that could be adjusted to provide up-, down-, or side-draughts for the calibration of a sensitive hot-wire anemometer. The readings on the instrument used were independent of the direction of air flow and the orientation of the instrument at velocities in excess of 10 ft. per min. At lower velocities separate curves were obtained for different instrument orientations and directions of air movement. Air flows as low as 1 ft. per min. can be estimated with useful accuracy provided the direction of air movement is known.

1983 ◽  
Vol 20 (2) ◽  
pp. 169-176
Author(s):  
M. J. Turner

An apparatus used in undergraduate instrumentation teaching is described. A small wind tunnel creates air speeds up to 12 m/s. A Pitot tube is used as a reference against which a hot wire anemometer is compared for linearity and transient response. The experiment serves to introduce non-ideal systems.


2018 ◽  
Vol 73 ◽  
pp. 01011
Author(s):  
Benediktus Yosef Arya Wastunimpuna ◽  
Wahyu Setia Budi ◽  
Erni Setyowati

The outside corridor of Dutch Colonial Building in Indonesia was made to make the temperature of the room more comfortable. Lawang Sewu Building in Semarang is one example of a building that has an outside corridor along the building and until now still use natural ventilation. This study focuses on finding out whether there is a difference on the thermal conditions of each room’s orientation, so after that we know the effect of orientation of the outdoor corridor to the temperature of the interior. In this study the experiment based on measurement using Heat Stress WBGT Meter for Wet Bulb Temperature, Dry Bulb Temperature, Relative Humidity, and KW0600653 Hot Wire Anemometer for the air movement. The data will be analysed using thermal standard theory to find out which point has the most comfortable thermal conditions.. At the end of this study will be found the effect of corridor’s orientation to thermal condition of the interior in Lawang Sewu Semarang.


2020 ◽  
Vol 32 (12) ◽  
pp. 125120
Author(s):  
María Jiménez-Portaz ◽  
Luca Chiapponi ◽  
María Clavero ◽  
Miguel A. Losada

1995 ◽  
Vol 6 (3) ◽  
pp. 201-206 ◽  
Author(s):  
J.C. Gibbings ◽  
J. Madadnia ◽  
S. Riley ◽  
A.H. Yousif

1999 ◽  
Vol 122 (1) ◽  
pp. 51-56 ◽  
Author(s):  
Riccardo Tresso ◽  
David R. Munoz

Detailed grid generated turbulent analysis has been completed using a three-dimensional hot-wire anemometer and traversing mechanism to identify a homogeneous, isotropic flow region downstream of a square mesh. The three-dimensional fluctuating velocity measurements were recorded along the centerline of a wind tunnel test section and spatially over the entire wind tunnel cross section downstream of the square mesh. Turbulent intensities for various grid sizes and Reynolds numbers ranged from a minimum of 0.2 percent to a maximum of 2.2 percent in each of the three principal velocity directions. Spatial homogeneity and isotropy were determined for several turbulent flow conditions and downstream positions using the method of covariances. Covariances, in theory, should approach zero asymptotically; however, in practice, this was not achievable. A subjective judgment is required to determine downstream location where the variance of the three covariances reaches a value close to zero. The average standard deviation provides an estimate for defining the limit or subjective threshold needed to determine the onset of homogeneous, isotropic flow. Implementing this threshold, a quantitative method was developed for predicting the streamwise location for the onset of the homogeneous, isotropic flow region downstream of a 25.4 mm square grid as a function of Reynolds number. A comparison of skewness, determined from one-dimensional hot wire anemometer measurements, and covariances, determined from three dimensional hot wire anemometer measurements, indicates a need for caution when relying solely on one-dimensional measurements for determination of turbulence isotropy. The comprehensive three-dimensional characterization also provides an improved understanding of spatial distribution of fundamental turbulence quantities generated by the grid within a low-speed wind tunnel. [S0098-2202(00)02501-3]


2019 ◽  
Vol 4 (2) ◽  
pp. 23 ◽  
Author(s):  
Thomas Neil McManus ◽  
Assed Haddad

This study reports on near-surface airspeed measured using a fast-responding thermoanemometer during an investigation of ventilation of an isolated subsurface structure induced by natural forces. Air speed changes continuously, rapidly, and unpredictably when assessed on the time base of one or two seconds. Zero, the most common air speed, occurred in almost all tests throughout the year but especially during cool and cold months. The most probable non-zero air speed, 10.7 m/min (35 ft/min), occurred in all tests. This air speed is below the level of detection by the senses. The number of zero values and the height of the peak at 10.7 m/min follow a repetitive annual cycle. Isolated subsurface structures containing manhole covers share the characteristics of Helmholtz resonators. Grazing air flow across the opening to the exterior induces rotational air flow in the airspace of a Helmholtz resonator. Rotational flow in the airspace potentially influences the exchange of the confined atmosphere with the external one. Ventilation of the airspace occurs continuously and without cost and is potentially enhanced by the unique characteristics of the Helmholtz resonator excited by surface air movement. These results have immense importance and immediate applicability to worker safety.


2000 ◽  
Vol 90 (2) ◽  
pp. 147-154 ◽  
Author(s):  
G.N. Mbata ◽  
S. Shu ◽  
S.B. Ramaswamy

Females of Callosobruchus spp. are known to produce sex pheromones that attract males. These sex pheromones cannot be adopted for use in pest management without first investigating the responses of the males in the windless conditions of storage environments. Consequently, behavioural bioassays of Callosobruchus subinnotatus Pic males were conducted in an olfactometer in the absence of air-flow. Under these conditions males were found to be able to follow odour trails to the source. However, the latency period was longer in diffusional bioassays than for insects in a Y-tube olfactometer that provided directional wind cues. The highest percentage of males reached the pheromone source when components of the pheromones, (E)-3-methyl-2-heptenoic acid (E32A) and (Z)-3-methyl-2-heptenoic acid (Z32A), were formulated in a 50:50 or 25:75 ratio. Males of C. maculatus (Fabricius) responded to sex pheromone of C. subinnotatus, but males of C. subinnotatus did not respond to that of C. maculatus. The two sex pheromone components of C. subinnotatus are also constituents of C. maculatus sex pheromone. These two components may be potentially useful in monitoring the populations of both species in stored beans. It is postulated that (Z)-3-methyl-3-heptenoic acid (Z33A), the major component of the sex pheromone of C. maculatus, must have acted as an antagonist inhibiting response of C. subinnotatus to the sex pheromone of C. maculatus.


1993 ◽  
Vol 59 (559) ◽  
pp. 935-940
Author(s):  
Yoshishige Ohyama ◽  
Khotarou Hirasawa ◽  
Yutaka Nishimura ◽  
Minoru Ohsuga ◽  
Mamoru Fujieda