Radiation Effects with a Model Lipid Membrane

1971 ◽  
Vol 49 (8) ◽  
pp. 1187-1196 ◽  
Author(s):  
A. Petkau

A cell is described that permits a model phospholipid membrane and the two adjacent aqueous compartments to be irradiated with a collimated beam of X-rays. During a 2 h irradiation a marked increase in [H+] in the aqueous phases is observed. A protonmotive force, given by the H+ Nernst potential, is generated when one compartment only is irradiated or when both compartments separated by a membrane made structurally asymmetric by the adsorption of alamethicin, are irradiated equally.The results of irradiations in N2O, N2, and O2 indicate that the membrane scavenges the superoxide O2−. The effect is discussed in terms of a clearing field that is derived from the potential at the membrane interfaces.

2007 ◽  
Vol 25 (1) ◽  
pp. 23-30 ◽  
Author(s):  
T. DESAI ◽  
R. DEZULIAN ◽  
D. BATANI

We present one-dimensional simulations performed using the multi group radiation hydro code MULTI with the goal of analyzing the target preheating effect under conditions similar to those of recent experiments aimed at studying the Equation of State (EOS) of various materials. In such experiments, aluminum is often used as reference material; therefore its behavior under strong shock compression and high-intensity laser irradiation (1013–1014 W/cm2) should be studied in detail. Our results reveal that at high laser irradiance, the laser energy available to induce shock pressure is reduced due to high X-rays generation. Simultaneously X-rays preheat the bulk of the reference material causing significant heating prior to shock propagation. Such effects induce deviations in shock propagation with respect to cold aluminum.


1996 ◽  
Vol 2 (2) ◽  
pp. 53-62 ◽  
Author(s):  
Henry N. Chapman ◽  
Jenny Fu ◽  
Chris Jacobsen ◽  
Shawn Williams

The methods of immunolabeling make visible the presence of specific antigens, proteins, genetic sequences, or functions of a cell. In this paper we present examples of imaging immunolabels in a scanning transmission x-ray microscope using the novel method of dark-field contrast. Colloidal gold, or silver-enhanced colloidal gold, is used as a label, which strongly scatters x-rays. This leads to a high-contrast dark-field image of the label and reduced radiation dose to the specimen. The x-ray images are compared with electron micrographs of the same labeled, unsectioned, whole cell. It is verified that the dark-field x-ray signal is primarily due to the label and the bright-field x-ray signal, showing absorption due to carbon, is largely unaffected by the label. The label can be well visualized even when it is embedded in or laying behind dense material, such as the cell nucleus. The resolution of the images is measured to be 60 nm, without the need for computer processing. This figure includes the x-ray microscope resolution and the accuracy of the label positioning. The technique should be particularly useful for the study of relatively thick (up to 10 μm), wet, or frozen hydrated specimens.


2013 ◽  
Vol 712-715 ◽  
pp. 293-297
Author(s):  
Li Li

Pt/Bi3.15Nd0.85Ti3O12(BNT)/Pt ferroelectric capacitors were monitored using in situ X-ray irradiation with 10 keV at BL14B1 beamline (Shanghai Synchrotron Radiation Facility). BL14B1 combined with a ferroelectric analyzer enabled measurements in situ of electrical performance. The hysteresis curve (PE) of distortion depended on the polarization during irradiation, but the diffracted intensities of the (117) peak did not change in the beginning. ThePEcurve had a negligible change from 2.09×109Gy to 4.45×109Gy. Finally, bothPrandPr+very rapidly increased, but the intensities of (117) decreased. The hysteresis loops were remarkably deformed at the maximum total dose of 4.87×109Gy.


2019 ◽  
Vol 290 ◽  
pp. 81-86
Author(s):  
Nur Shafawati binti Rosli ◽  
Azhar Abdul Rahman ◽  
Azlan Abdul Aziz ◽  
Shaharum Shamsuddin ◽  
Suhana Arshad

Radiation therapy and chemotherapy remain the most widely used treatment options in treating cancer. Recent developments in cancer research show that therapy combined with high-atomic number materials such as gold nanoparticles (AuNPs) is a new way to treat cancer, in which AuNPs are injected through intravenous administration and bound to tumor sites has enhanced tumor cell killing. Radiation therapy aims to deliver a high therapeutic dose of ionizing radiation to the tumor without exceeding normal tissue tolerance. In this work AuNPs have been used for the enhancement of radiation effects on breast cancer cells (MCF-7) for superficial kilovoltage X-ray radiation therapy. The use of AuNPs in superficial kilovoltage X-ray beams radiation therapy will provide a high probability for photon interaction by photoelectric effect. These provide advantages in terms of radiation dose enhancement. In this work, MCF-7 cells were seeded in the 96-well plate and treated with 13 nm, 50 nm and 70 nm AuNPs before they were irradiated with 80 kVp X-rays beam at various radiation doses. Photoelectric effect is the dominant process of interaction of 80 kVp X-rays with AuNPs. When the AuNPs are internalized into the MCF-7 cells, the dose enhancement effect is observed. The presence of AuNPs in the MCF-7 cells will produce a higher number of photoelectrons, and resulting more “free radicals” that will lead to increase in cell death. Then, these free radicals will lead to DNA damage to the MCF-7 cells. To validate the enhanced killing effect, both with and without AuNPs MCF-7 cells is irradiated simultaneously. By comparison, the results show that AuNPs significantly enhance cancer killing and the enhancement radiation effect was dependent on the size of AuNPs.


2019 ◽  
Vol 31 (5) ◽  
pp. 1169-1175
Author(s):  
S. Sivakumar ◽  
S. Rameshkumar ◽  
S. Sathishkumar ◽  
A. Sankar

Artificial planar bilayer phospholipid membrane was formed in KCl bath solutions and its electrical properties have been analyzed using electrochemical impedance spectroscopy. The stability of planar bilayer lipid membrane depends on concentration of KCl in the bath. Changes in the electrical properties of planar bilayer lipid membrane with the addition of lorazepam were also studied using electrochemical impedance spectroscopy. Lorazepam gets partitioned into bilayer lipid membrane and exhibited a fluidization effect. The ionic conductance across the bilayer lipid membrane increased with the addition of lorazepam to the bath. An impedimetric sensor was developed for quantification of lorazepam in solution.


1955 ◽  
Vol 38 (5) ◽  
pp. 581-598 ◽  
Author(s):  
Margaret R. McDonald

The proteolytic activity of dilute solutions of clystalline trypsin is destroyed by x-rays, the amount of inactivation being an exponential function of the radiation dose. The reaction yield increases steadily with increasing concentration of trypsin, varying, as the concentration of enzyme is increased from 1 to 300 µM, from 0.068 to 0.958 micromole of trypsin per liter inactivated per 1000 r with 0.005 N hydrochloric acid as the solvent, from 0.273 to 0.866 with 0.005 N sulfuric acid as the solvent, and from 0.343 to 0.844 with 0.005 N nitric acid as the solvent. When the reaction yields are plotted as a function of the initial concentration of trypsin, they fall on a curve given by the expression Y α XK, in which Y is the reaction yield, X is the concentration of trypsin, and K is a constant equal to 0.46, 0.20, and 0.16, respectively, with 0.005 N hydrochloric, sulfuric, and nitric acids as solvents. The differences between the reaction yields found with chloride and sulfate ions in I to 10 µM trypsin solutions are significant only in the pH range from 2 to 4. The amount of inactivation obtained with a given dose of x-rays depends on the pH of the solution being irradiated and the nature of the solvent. The reaction yield-pH curve is a symmetrical one, with minimum yields at about pH 7. Buffers such as acetate, citrate, borate and barbiturate, and other organic molecules such as ethanol and glucose, in concentrations as low as 20 µM, inhibit the inactivation of trypsin by x-radiation. Sigmoid inactivation-dose curves instead of exponential ones are obtained in the presence of ethanol. The reaction yields for the inactivation of trypsin solutions by x-rays are approximately 1.5 times greater when the irradiation is done at 26°C. than when it is done at 5°C., when 0.005 N hydrochloric acid is the solvent. The dependence on temperature is less when 0.005 N sulfuric acid is used, and is negligible with 0.005 N nitric acid. The difficulties involved in interpreting radiation effects in aqueous systems, and in comparing the results obtained under different experimental conditions, are discussed.


Langmuir ◽  
2017 ◽  
Vol 33 (29) ◽  
pp. 7332-7342 ◽  
Author(s):  
Saziye Yorulmaz Avsar ◽  
Joshua A. Jackman ◽  
Min Chul Kim ◽  
Bo Kyeong Yoon ◽  
Walter Hunziker ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document