EARLY RESULTS FROM THE HIGH-RESOLUTION FLY's EYE

2001 ◽  
Vol 16 (supp01c) ◽  
pp. 1019-1021
Author(s):  
JOHN BELZ

The High-Resolution Fly's Eye cosmic ray observatory has been operating in monocular (stereo) mode for about three years (one year), during which time we have observed extensive airshowers with an integrated aperture of ~ 1500 km2-sr-yr (~ 400 km-sr-yr) at 5×1019 eV. We describe the HiRes experiment and the nitrogen fluorescence technique, and present data taken in both monocular and stereo modes including preliminary energy spectra.

2008 ◽  
Vol 23 (17n20) ◽  
pp. 1290-1300 ◽  
Author(s):  
PIERRE SOKOLSKY

Results from the High Resolution Fly's Eye (HiRes) experiment and the Pierre Auger Observatory (PAO) on the observation of the Greissen-Zatsepin-Kuzmin cutoff in the cosmic ray spectrum are presented. Both experiments observe a cutoff consistent with the GZK predictions with a five and six sigma significance respectively. The nature of the cosmic ray composition near the GZK cutoff is discussed as well as the recent claim of a correlation of the highest energy cosmic rays with AGNs in the Southern sky.


1998 ◽  
Vol 15 (3) ◽  
pp. 332-335 ◽  
Author(s):  
R. W. Clay ◽  
N. R. Wild ◽  
D. J. Bird ◽  
B. R. Dawson ◽  
M. Johnston ◽  
...  

AbstractA cloud monitor has been developed for use with cosmic ray air shower fluorescence detectors, the High Resolution Fly's Eye and the Pierre Auger Observatory. This is based on an infrared thermopile device which, unlike previous such monitors, requires no moving chopper and is suitable for unattended operation over long periods of time.


2021 ◽  
pp. 021849232110068
Author(s):  
Simon CY Chow ◽  
Jacky YK Ho ◽  
Micky WT Kwok ◽  
Takuya Fujikawa ◽  
Kevin Lim ◽  
...  

Background Coronary endarterectomy aims to improve completeness of revascularization in patients with occluded coronary vessels. The benefits of coronary endarterectomy remain uncertain. The aim of this study was to evaluate short-term surgical outcomes and factors affecting graft patency post-coronary endarterectomy. Methods Between 2009 and 2019, 81 consecutive patients who had coronary endarterectomy done were evaluated for their perioperative and early results. A total of 36 patients with follow-up coronary studies were included in patency analysis. Mortality rates, major adverse cardiac and cerebrovascular events, and graft patency were outcomes of interest. Survival and risk factor analysis were performed with Kaplan–Meier and logistic regression analysis. Results The average age of the cohort was 61.9 ± 9.29 years. Complete revascularization rate was 95.4% post-coronary endarterectomy. The 30-day and 1-year mortality was 2.5 and 6.2%, respectively. One-year major adverse cardiac and cerebrovascular events rate was 11.1%. Periprocedural myocardial infarction rate was 7.4%. Three patients required repeat revascularization within a mean follow-up duration of 49.6 ± 36.5 months. Overall graft patency was 89.2% at 20.2 months and graft patency post-coronary endarterectomy was 85.4%. Arterial grafts showed 100% patency. Vein grafts to endarterectomized obtuse marginal branch had patency rates of 33.3%. Multiple endarterectomies were associated with worse one-year major adverse cardiac and cerebrovascular events (OR: 28.6 ± 1.16; P = 0.003). Conclusions Coronary endarterectomy facilitates completeness of revascularization and does not increase early mortality. Graft patency post-coronary endarterectomy on obtuse marginal artery was suboptimal. Judicious use of coronary endarterectomy should be practiced to balance the need of completeness of revascularization against the risk of myocardial infarction.


Vascular ◽  
2020 ◽  
pp. 170853812098112
Author(s):  
Cassra N Arbabi ◽  
Navyash Gupta ◽  
Ali Azizzadeh

Objectives Thoracic endovascular aortic repair (TEVAR) is the standard of care for descending thoracic aortic aneurysms (DTAA), and newer generation stent grafts have significant design improvements compared to earlier generation devices. Methods We report the first commercial use of the Medtronic Valiant Navion stent graft for treatment of an 85-year-old woman with a 5.8 cm DTAA and a highly tortuous thoracic aorta. Results A percutaneous TEVAR was performed using a two-piece combination of the Valiant Navion FreeFlo and CoveredSeal stent graft configurations for zones 2–5 coverage. The devices were successfully delievered through highly tortuous anatomy and deployed, excluding the entire length of the aneurysm with precise landing, excellent apposition and no evidence of endoleak. The patient tolerated the procedure well and has had no stent graft-related complications through one-year follow-up. Conclusions Design enhancements such as a lower profile delivery system, better conformability, and a shorter tapered tip are some of the improvements to this third-generation TEVAR device. Coupled with the multiple configuration options available, this gives physicians a better tool to treat thoracic aortic pathologies in patients with challenging anatomy. The early results are encouraging, and evaluation of long-term outcomes will continue.


2019 ◽  
Vol 11 (24) ◽  
pp. 2893 ◽  
Author(s):  
Yi-Chun Lin ◽  
Yi-Ting Cheng ◽  
Tian Zhou ◽  
Radhika Ravi ◽  
Seyyed Hasheminasab ◽  
...  

Unmanned Aerial Vehicle (UAV)-based remote sensing techniques have demonstrated great potential for monitoring rapid shoreline changes. With image-based approaches utilizing Structure from Motion (SfM), high-resolution Digital Surface Models (DSM), and orthophotos can be generated efficiently using UAV imagery. However, image-based mapping yields relatively poor results in low textured areas as compared to those from LiDAR. This study demonstrates the applicability of UAV LiDAR for mapping coastal environments. A custom-built UAV-based mobile mapping system is used to simultaneously collect LiDAR and imagery data. The quality of LiDAR, as well as image-based point clouds, are investigated and compared over different geomorphic environments in terms of their point density, relative and absolute accuracy, and area coverage. The results suggest that both UAV LiDAR and image-based techniques provide high-resolution and high-quality topographic data, and the point clouds generated by both techniques are compatible within a 5 to 10 cm range. UAV LiDAR has a clear advantage in terms of large and uniform ground coverage over different geomorphic environments, higher point density, and ability to penetrate through vegetation to capture points below the canopy. Furthermore, UAV LiDAR-based data acquisitions are assessed for their applicability in monitoring shoreline changes over two actively eroding sandy beaches along southern Lake Michigan, Dune Acres, and Beverly Shores, through repeated field surveys. The results indicate a considerable volume loss and ridge point retreat over an extended period of one year (May 2018 to May 2019) as well as a short storm-induced period of one month (November 2018 to December 2018). The foredune ridge recession ranges from 0 m to 9 m. The average volume loss at Dune Acres is 18.2 cubic meters per meter and 12.2 cubic meters per meter within the one-year period and storm-induced period, respectively, highlighting the importance of episodic events in coastline changes. The average volume loss at Beverly Shores is 2.8 cubic meters per meter and 2.6 cubic meters per meter within the survey period and storm-induced period, respectively.


Sign in / Sign up

Export Citation Format

Share Document