THE ERROR MINIMIZATION OF DIGITAL FOURIER FILTER USED IN UNIPROCESSOR PROTECTIVE RELAYING FOR 6–33 kV ELECTRICAL NETWORKS

2005 ◽  
Vol 14 (05) ◽  
pp. 953-963
Author(s):  
ABDULLAH I. AL-ODIENAT ◽  
OMAR Y. RADAIDEH

In this paper, a new method for error minimization of digital Fourier filter is proposed. The proposed method is tested by operating the electrical networks at oscillatory frequency. The functional features of microprocessor protective relaying and automatic switching devices are considered. The software structure of uniprocessor protective relaying and automatic switching equipments for the 6–33 kV lines are also presented.

2019 ◽  
Vol 139 ◽  
pp. 01078 ◽  
Author(s):  
A.G. Saidkhodjaev ◽  
A.M. Najimova ◽  
A.K. Bijanov

In this article, we propose a new method for determining the maximum load of electric consumers in urban electric networks, which differs from existing methods in more accurate and reliable determination of the maximum loads. Based on the determination of the maximum loads of the objects of urban electrical networks, it is concluded that the proposed methods are determined by high accuracy and minor errors.


2019 ◽  
Vol 124 ◽  
pp. 02013 ◽  
Author(s):  
D. D. Micu ◽  
I. V. Ivshin ◽  
E. I. Gracheva ◽  
O. V. Naumov ◽  
A. N. Gorlov

This paper presents calculation of resistance of tightening contact joints of switching devices. It allows considering the technical condition of low-voltage switching equipment and to specify energy emitted in the switching device in the mode of electrical networks operation is presented in the article.


2021 ◽  
Vol 2096 (1) ◽  
pp. 012180
Author(s):  
I V Naumov ◽  
M N Polkovskaya

Abstract The structure study, condition and 10 kV electric networks reliability level in the Irkutsk region for the period from 2016 to 2020 is carried out. The analysis is based on real data on the studied electric networks published in the open press. The Interactive Matlab system libraries and interfaces were used to calculate and analyze the studied indicator. The considered electric networks structure has investigated, algorithms and computer programs for the Matlab graphic editor are compiled with the help which changes time diagrams in the failures number, the interruptions time and the under-output electricity amount for each year months are constructed. The year months in which the highest damage occurs were determined. The electrical networks wear is considered, as well as the repair plan implementation for the main equipment. The reliability level according to the established indicators has analyzed, the main reasons for equipment failure are considered. The characteristics of improving considered electrical networks functioning are presented. Based on the conducted studies, it was found that the most damaged the considered overhead lines elements are: wires, supports, insulators, and switching devices. The characteristic reasons that lead to their damage are: wind load, damage to switching devices. The greatest damage is the Angarsky and Irkutsky branches networks characteristic (the average annual value all failures are 26.4 and 23.9%). The Kirensky and Cheremkhovsky branches networks are the least damaged annually. The obtained data probabilistic-statistical and correlation analysis, as well as the emergency outages risks analysis for the future, taking into account the seasonal component, is carried out.


2012 ◽  
Vol 548 ◽  
pp. 560-565
Author(s):  
Yu Han Zhang ◽  
An Dong Lang

The paper proposes a method for the selection of the optimal solution among different feasible solutions of the SHEPWM nonlinear model. The method regards the power losses of the switching devices as a criterion for evaluating the possible groups of solutions. The overall power losses are calculated under each combination of the switching angles at first. The variation track of the power losses that could determine the optimal solution under the specific value of m is presented later. The simulation results contrast the new method with the traditional THD method. A comprehensive evaluation considering both methods was concluded at last.


2019 ◽  
Vol 124 ◽  
pp. 02011 ◽  
Author(s):  
A. V. Vinogradov ◽  
A. V. Vinogradova ◽  
M. O. Ward ◽  
A. N. Kharkhardin ◽  
A. I. Psaryov ◽  
...  

The overestimated length of rural power lines of 0.38 kV leads to the fact that it is often not possible to fulfill both the sensitivity conditions of the protective device installed at the transformer substation and protecting the line from overloads and short circuits, and the requirements of the power supply reliability of consumers. This problem can be solved by installing in-line universal sectionalizing point equipped with an automatic load transfer function. The use of these devices allows dividing a line into sections provides the necessary sensitivity of protection for each section of the line and the possibility of supplying power to undamaged areas from a backup power source. In addition, only with the use of automated switching devices installed in power lines, it is possible to create intelligent electrical networks. When developing these devices, it is necessary to take into account the electromechanical characteristics of switching devices that are planned to be used for switching lines.


Sign in / Sign up