Experimental Investigation on Stability of Circular Steel Tubular Stub Columns at Elevated Temperatures Under Axial Compression

2019 ◽  
Vol 19 (06) ◽  
pp. 1950063 ◽  
Author(s):  
Kang He ◽  
Yu Chen

This paper studies the structural stability of circular steel tubular stub columns at elevated temperatures under axial compression. Fifty-one specimens are subjected to high-temperature treatment and axial compression. The variables of the specimen are temperature, wall thickness of steel tube and duration of high temperature. The displacement–load curve, strain–load curve, ultimate load, axial compressive stiffness and failure characteristics of the specimens were analyzed. Test results show that after exposure to high temperatures, the specimens’ failure phenomenon in the axial compression loading test is consistent with that at room temperature, the bearing capacity decreases considerably, the ductility decreases slightly and the axial compressive stiffness changes irregularly. Temperature is the determining factor of the ultimate load of the specimen, and the reducing extent of ultimate load increases with the temperature. When the temperature reaches 1000∘C, its maximum reducing extent exceeds 50%. Among the three parameters considered in this study, the duration of high temperature has the least influence on the specimen.

Materials ◽  
2020 ◽  
Vol 13 (3) ◽  
pp. 795 ◽  
Author(s):  
Fengjie Zhang ◽  
Junwu Xia ◽  
Guo Li ◽  
Zhen Guo ◽  
Hongfei Chang ◽  
...  

This work aimed to investigate the effects of steel tube corrosion on the axial ultimate load-bearing capacity (AULC) of circular thin-walled concrete-filled steel tubular (CFST) members. Circular thin-walled CFST stub column specimens were made of steel tubes with various wall-thicknesses. These CFST column specimens were subjected to an accelerated corrosion test, where the steel tubes were corroded to different degrees of corrosion. Then, these CFST specimens with corroded steel tubes experienced an axial static loading test. Results show that the failure patterns of circular thin-walled CFST stub columns with corroded steel tubes are different from those of the counterpart CFST columns with ordinary wall-thickness steel tubes, which is a typical failure mode of shear bulging with slight local outward buckling. The ultimate strength and plastic deformation capacity of the CFST specimens decreased with the increasing degree of steel corrosion. The failure modes of the specimens still belonged to ductile failure because of the confinement of outer steel tube. The degree of steel tube corrosion, diameter-to-thickness ratio, and confinement coefficient had substantial influences on the AULC and the ultimate compressive strength of circular thin-walled CFST stub columns. A simple AULC prediction model for corroded circular thin-walled CFST stub columns was presented through the regression of the experimental data and parameter analysis.


2021 ◽  
Vol 2021 ◽  
pp. 1-18
Author(s):  
Jing Ji ◽  
Maomao Yang ◽  
Zhichao Xu ◽  
Liangqin Jiang ◽  
Huayu Song

The behavior of H-shaped honeycombed stub columns with rectangular concrete-filled steel tube flanges (STHCCs) subjected to axial load was investigated experimentally. A total of 16 specimens were studied, and the main parameters varied in the tests included the confinement effect coefficient of the steel tube (ξ), the concrete cubic compressive strength (fcu), the steel web thickness (t2), and the slenderness ratio of specimens (λs). Failure modes, load-displacement curves, load-strain curves of the steel tube flanges and webs, and force mechanisms were obtained by means of axial compression tests. The parameter influences on the axial compression bearing capacity and ductility were then analyzed. The results showed that rudder slip diagonal lines occur on the steel tube outer surface and the concrete-filled steel tube flanges of all specimens exhibit shear failure. Specimen load-displacement curves can be broadly divided into elastic deformation, elastic-plastic deformation, and load descending and residual deformation stages. The specimen axial compression bearing capacity and ductility increase with increasing ξ, and the axial compression bearing capacity increases gradually with increasing fcu, whereas the ductility decreases. The ductility significantly improves with increasing t2, whereas the axial compression bearing capacity increases slightly. The axial compression bearing capacity decreases gradually with increasing λs, whereas the ductility increases. An analytical expression for the STHCC short column axial compression bearing capacity is established by introducing a correction function ( w ), which has good agreement with experimental results. Finally, several design guidelines are suggested, which can provide a foundation for the popularization and application of this kind of novel composite column in practical engineering projects.


2013 ◽  
Vol 838-841 ◽  
pp. 439-443 ◽  
Author(s):  
Zhi Liang Zuo ◽  
Da Xin Liu ◽  
Jian Cai ◽  
Chun Yang ◽  
Qing Jun Chen

To improve the mechanical behavior of T-shaped concrete-filled steel tubular (T-CFT) column, the method that setting binding bars along the height of steel tube is proposed. Five T-CFT stub columns with binding bars and another two without binding bars subjected to axial compression were tested. The influences of the spacing and diameter of binding bars on the failure modes, maximum strength, and ductility of T-CFT stub columns are investigated. The experimental results demonstrate that by setting binding bars or decreasing the spacing of binding bars, the buckling modes of the steel plates are changed, the local buckling of the steel plates is postponed, and the confinement effects on the core concrete can be improved significantly. By setting binding bars, the bearing capacity and ductility of the columns are enhanced by 1.17 and 3.38 times at most, respectively. By increasing the diameter of binding bars, the ductility of the columns is improved, but the bearing capacity and buckling strength cannot be improved when the diameter is large enough.


2012 ◽  
Vol 166-169 ◽  
pp. 859-862 ◽  
Author(s):  
Yong Jin Li ◽  
Qing Xin Ren ◽  
Fei Yu Liao

Concrete filled steel tube (CFST) reinforced concrete (CFSTRC) columns subjected to axial compression were experimentally investigated in this paper. A total of ten specimens were tested. The main parameters varied in the experiments were steel tube ratio and concrete strength. It was found that, under axial compression, the column ultimate strength increases with the increasing of steel tube ratio and concrete strength. The work in this paper provides a basis for the further theoretical study on the behavior of CFSTRC columns.


2019 ◽  
Vol 23 (7) ◽  
pp. 1383-1396 ◽  
Author(s):  
Youwu Xu ◽  
Jian Yao ◽  
Xin Sun

Concrete-filled steel tubular columns are widely used in structural systems, and elliptical concrete-filled steel tubular columns are receiving more and more attention. An experimental study on cold-formed elliptical concrete-filled steel tubular stub columns was carried out under monotonic and cyclic axial compression. The failure modes, axial load–displacement curves, ultimate loads, hoop strain–axial strain behavior, strength deterioration, and residual deformation were obtained and discussed. Complementary finite element models considering the complex non-uniform confinement between steel tube and concrete were developed and validated by experimental results. Then, the validated FE model was used to study the influence of aspect ratio, yield strength of steel, and compressive strength of concrete on the axial capacity of elliptical concrete-filled steel tubular stub columns. Finally, a relatively simple superposition method was put forward to predict the axial bearing capacity of elliptical concrete-filled steel tubular stub columns. Compared with the test data, both the numerical method and superposition method can generate accurate predictions.


2018 ◽  
Vol 38 ◽  
pp. 03035
Author(s):  
Ji Zhong Wang ◽  
Lu Cheng ◽  
Xin Pei Wang

A new column of FRP composite tube confined steel-reinforced concrete (FTCSRC) column was proposed. This paper elaborates on laboratorial and analytical studies on the behavior of FCTSRC columns subjected to axial compressive load. Eight circular FTCSRC stub columns and one circular steel tube confined concrete (STCC) stub column were tested to investigate the failure mode and axial compression performance of circular FTCRSC columns. Parametric analysis was implemented to inquire the influence of confinement material (CFRP-steel tube or CFRP-GFRP tube), internal steel and CFRP layers on the ultimate load capacity. CFRP-steel composite tube was composed of steel tube and CFRP layer which was wrapped outside the steel tube, while CFRP-GFRP composite tube was composite of GFRP tube and CFRP layer. The test results indicate that the confinement effect of CFRP-steel tube is greatly superior to CFRP-GFRP tube. The ductility performance of steel tube confined high-strength concrete column can be improved obviously by encasing steel in the core concrete. Furthermore, with the increase in the layers of FRP wraps, the axial load capacity increases greatly.


Sign in / Sign up

Export Citation Format

Share Document