APPLICATION OF HYDROCARBON BASED REFRIGERANTS FOR AIR CONDITIONING IN INDONESIA

2011 ◽  
Vol 19 (04) ◽  
pp. 303-309 ◽  
Author(s):  
ARI D. PASEK ◽  
ARYADI SUWONO

Electrical energy consumption in air conditioning systems reaches 60% to 70% of the total electric energy consumption in buildings. Therefore, saving electrical energy consumption in air conditioning systems would have a significant impact on the national electrical energy consumption. Currently, the air conditioning sectors were having a dilemma on finding the alternative substitutes for CFC and HCFC refrigerants which are proven to cause destruction of the ozone layer and contribute to the effects of global warming. This paper will discuss the problems faced by an Article 5 country similar to Indonesia in phasing-out HCFC especially in air conditioning and refrigeration sectors. This paper will also discuss the possibility to use hydrocarbon-based refrigerants, which have zero ozone depletion potential (ODP) and low global warming potential (GWP), in air conditioning sectors. Some results of field applications of this refrigerant will be reported, and in general it can be concluded that the air conditioning retrofitted with hydrocarbon refrigerant consumes 10%–20% less electrical energy. Mixture of R-290 and R-134a was also investigated. R-134a is used to reduce the flammability of R-290 and to make the saturation pressure close to R-22. The results show that at composition of 0.6 R-290/0.4 R-134a mole fractions, the mixture behave as an azeotrope refrigerant mixture and can be used for R-22 replacement. At this composition, lower flammability limit (LEL) is 3693%, which is higher than pure R-290. Hence, the refrigerant mixture can be classified as less flammable A2 class refrigerant. The performance test shows that the refrigerant mixture can be used as a drop-in refrigerant in the R-22 machine. The measurement of refrigeration capacity and compressor input work at the same chilled water temperature shows that the calculated COP of the refrigerant mixture is better than R-22's but lower than R-290's.

2012 ◽  
Vol 16 (3) ◽  
pp. 131
Author(s):  
Didik Ariwibowo

Didik Ariwibowo, in this paper explain that energy audit activities conducted through several phases, namely: the initial audit, detailed audit, analysis of energy savings opportunities, and the proposed energy savings. Total energy consumed consists of electrical energy, fuel, and materials in this case is water. Electrical energy consumption data obtained from payment of electricity accounts for a year while consumption of fuel and water obtained from the payment of material procurement. From the calculation data, IKE hotels accounted for 420.867 kWh/m2.tahun, while the IKE standards for the hotel is 300 kWh/m2.tahun. Thus, IKE hotel included categorized wasteful in energy usage. The largest energy consumption on electric energy consumption. Largest electric energy consumption is on the air conditioning (AC-air conditioning) that is equal to 71.3%, and lighting and electrical equipment at 27.28%, and hot water supply system by 4.44%. Electrical energy consumption in AC looks very big. Ministry of Energy and Mineral Resources of the statutes, the profile of energy use by air conditioning at the hotel by 48.5%. With these considerations in the AC target for audit detail as the next phase of activity. The results of a detailed audit analysis to find an air conditioning system energy savings opportunities in pumping systems. Recommendations on these savings is the integration of automation on the pumping system and fan coil units (FCU). The principle of energy conservation in the pumping system is by installing variable speed drives (VSD) pump drive motor to adjust speed according to load on the FCU. Load variations FCU provide input on the VSD pumps to match. Adaptation is predicted pump can save electricity consumption up to 65.7%. Keywords: energy audit, IKE, AC


2020 ◽  
Vol 26 (19-20) ◽  
pp. 1804-1814
Author(s):  
Renkai Ding ◽  
Ruochen Wang ◽  
Xiangpeng Meng ◽  
Long Chen

To coordinate the contradictory relationship between dynamic performances and electrical energy consumption of an electromagnetic active suspension, a hybrid electromagnetic actuator that integrates with a linear motor and a hydraulic damper is developed, which can achieve active control and energy regeneration compared with the linear electromagnetic actuator. A mode-switching control method is put forward based on the modified skyhook control. The stability of the switched controller with a specific switching rule is investigated based on the Lyapunov theorem. Then, the switching control system of a hybrid electromagnetic actuator is designed. Finally, a linear electromagnetic actuator and a passive damper are taken as comparison objects, and comparative bench tests, including a dynamic performance test and an energy consumption test, are conducted. The test results show that the hybrid electromagnetic actuator with mode-switching control can balance the dynamic performances and electrical energy consumption effectively.


2021 ◽  
Vol 289 ◽  
pp. 01014
Author(s):  
Ahmed Al–Okbi ◽  
Yuri Vankov ◽  
Hakim Kadhim

At the present time, operating hybrid air-conditioning systems that use solar energy to saving electrical energy while improving the performance has become necessary to protect the environment, reduce pollution and emissions caused by using fuels and gases. In Iraq, temperatures reach half the boiling point at summer, therefore the demand for air conditioning systems increases, air conditioning systems consume more than half of average electricity production which affects on reliability and stability of the electrical energy thus leads to a continuous power outage. So, the issue of using renewable energies becomes more attractive. Because of saving energy leads to ensuring the reliability of electricity and reduces the consumption of fuels and gases that pollute on the environment and negatively affect on the ozone layer. In the current research, the atmosphere of Baghdad city was used to collect solar thermal energy and convert it into thermal energy through an evacuated solar collector by water and combine it with a conventional air conditioner in the part that follows the compressor in order to reduce the electrical energy consumption on the compressor and increase coefficient of performance. Several tests were conducted on the proposed system to compare results with the conventional system and evaluate performance. The results showed that the coefficient of performance with the hybrid system became 8.97 more efficient instead of 4.27 compared to the conventional system, and the energy consumption decreased by 52%.


2014 ◽  
Vol 22 (02) ◽  
pp. 1440005 ◽  
Author(s):  
MARK SPATZ ◽  
SAMUEL YANA MOTTA ◽  
CHRISTOPHER SEETON ◽  
YONGMING NIU

Due to the growing global concerns around the use of refrigerants with relatively high global warming potential, new refrigerants with the positive attributes of both high thermal performance and low environmental impact are currently in development by Honeywell. These new refrigerants exhibit promising performance when compared with refrigerants currently used in stationary AC systems such as those that use R-410A, R-407C, and R-134a, for example. These new refrigerants also show significantly lower flammability characteristics than the much more flammable hydrocarbons. Replacements of common HFC refrigerants such as R-410A and R-407C are discussed for residential air conditioning applications. Thermal properties as well as experimental results in representative air conditioning systems are presented, showing the benefits of using these new refrigerants.


2013 ◽  
Vol 388 ◽  
pp. 91-95 ◽  
Author(s):  
Henry Nasution ◽  
Abdul Latiff Zulkarnain ◽  
Azhar Abdul Aziz ◽  
Mohd Rozi Mohd Perang

An experimental study to evaluate the energy consumption of a split type air conditioning is presented. The compressor works with the fluids R-22 and HCR-22 and has been tested varying the internal heat load 0, 500, 700 and 1000 W. The measurements taken during the one hour experimental periods at 10-minutes interval times for temperature setpoint of 20oC. The performance data considered where the evaporator cooling load, the condenser heat rejection, the electrical energy consumption, the refrigeration system temperatures, and the room temperature. And hence the Coefficient of Performance (COP) could be determined. The final results of this study show an overall better energy consumption of the HFC-22 compared with the R-22.


2019 ◽  
pp. 149-154
Author(s):  
Evtaleny R Mauboy

Abstract— The Energy Audit is an assessment of energy consumption and the identification of energy savings, as well as recommendations to increase the efficiency of energy consumption and use of energy sources in the context of energy saving. This study aims to describe the testing of electrical energy in the rooms of the Sotis Kupang Hotel from the 2nd (second) to the 6th (sixth) floor, taking samples of 7 (seven) different room types and carried out a test of electrical energy in relation to the use of lamps and air conditioning. The method used in this study is data collection, survey, observation and direct measurement of the use of light and AC (air conditioning). The data analysis technique used is to determine the estimated value of the electrical energy consumption and the value of the energy consumption intensity (IKE). The calculation and analysis show the value of IKE is 30.96 kWh / m2/ year, which is categorized as "very efficient". The IKE value for the use of AC (air conditioning) is 206.33 kWh / m2/ year and which is categories as "somewhat wasteful". The calculation of the PHE (energy savings) results in a PHE for the use of AC of 172.88 kWh / m2/ year, which falls into the category of "fairly efficient.


2021 ◽  
pp. 1-15
Author(s):  
Fernanda P. Mota ◽  
Cristiano R. Steffens ◽  
Diana F. Adamatti ◽  
Silvia S. Da C Botelho ◽  
Vagner Rosa

Energies ◽  
2020 ◽  
Vol 14 (1) ◽  
pp. 81
Author(s):  
Rongjiang Ma ◽  
Shen Yang ◽  
Xianlin Wang ◽  
Xi-Cheng Wang ◽  
Ming Shan ◽  
...  

Air-conditioning systems contribute the most to energy consumption among building equipment. Hence, energy saving for air-conditioning systems would be the essence of reducing building energy consumption. The conventional energy-saving diagnosis method through observation, test, and identification (OTI) has several drawbacks such as time consumption and narrow focus. To overcome these problems, this study proposed a systematic method for energy-saving diagnosis in air-conditioning systems based on data mining. The method mainly includes seven steps: (1) data collection, (2) data preprocessing, (3) recognition of variable-speed equipment, (4) recognition of system operation mode, (5) regression analysis of energy consumption data, (6) constraints analysis of system running, and (7) energy-saving potential analysis. A case study with a complicated air-conditioning system coupled with an ice storage system demonstrated the effectiveness of the proposed method. Compared with the traditional OTI method, the data-mining-based method can provide a more comprehensive analysis of energy-saving potential with less time cost, although it strongly relies on data quality in all steps and lacks flexibility for diagnosing specific equipment for energy-saving potential analysis. The results can deepen the understanding of the operating data characteristics of air-conditioning systems.