Giant Vesicles and Their Use in Assays for Assessing Membrane Phase State, Curvature, Mechanics, and Electrical Properties

2019 ◽  
Vol 48 (1) ◽  
pp. 93-119 ◽  
Author(s):  
Rumiana Dimova

Giant unilamellar vesicles represent a promising and extremely useful model biomembrane system for systematic measurements of mechanical, thermodynamic, electrical, and rheological properties of lipid bilayers as a function of membrane composition, surrounding media, and temperature. The most important advantage of giant vesicles over other model membrane systems is that the membrane responses to external factors such as ions, (macro)molecules, hydrodynamic flows, or electromagnetic fields can be directly observed under the microscope. Here, we briefly review approaches for giant vesicle preparation and describe several assays used for deducing the membrane phase state and measuring a number of material properties, with further emphasis on membrane reshaping and curvature.

2015 ◽  
Vol 147 (1) ◽  
pp. 77-93 ◽  
Author(s):  
Hui Zheng ◽  
Sungsoo Lee ◽  
Marc C. Llaguno ◽  
Qiu-Xing Jiang

Fused or giant vesicles, planar lipid bilayers, a droplet membrane system, and planar-supported membranes have been developed to incorporate membrane proteins for the electrical and biophysical analysis of such proteins or the bilayer properties. However, it remains difficult to incorporate membrane proteins, including ion channels, into reconstituted membrane systems that allow easy control of operational dimensions, incorporation orientation of the membrane proteins, and lipid composition of membranes. Here, using a newly developed chemical engineering procedure, we report on a bead-supported unilamellar membrane (bSUM) system that allows good control over membrane dimension, protein orientation, and lipid composition. Our new system uses specific ligands to facilitate the unidirectional incorporation of membrane proteins into lipid bilayers. Cryo–electron microscopic imaging demonstrates the unilamellar nature of the bSUMs. Electrical recordings from voltage-gated ion channels in bSUMs of varying diameters demonstrate the versatility of the new system. Using KvAP as a model system, we show that compared with other in vitro membrane systems, the bSUMs have the following advantages: (a) a major fraction of channels are orientated in a controlled way; (b) the channels mediate the formation of the lipid bilayer; (c) there is one and only one bilayer membrane on each bead; (d) the lipid composition can be controlled and the bSUM size is also under experimental control over a range of 0.2–20 µm; (e) the channel activity can be recorded by patch clamp using a planar electrode; and (f) the voltage-clamp speed (0.2–0.5 ms) of the bSUM on a planar electrode is fast, making it suitable to study ion channels with fast gating kinetics. Our observations suggest that the chemically engineered bSUMs afford a novel platform for studying lipid–protein interactions in membranes of varying lipid composition and may be useful for other applications, such as targeted delivery and single-molecule imaging.


2011 ◽  
Vol 9 ◽  
pp. 19-26
Author(s):  
M. Rohland ◽  
U. Arz ◽  
S. Büttgenbach

Abstract. In this work we compare on-wafer calibration standards fabricated in membrane technology with standards built in conventional thin-film technology. We perform this comparison by investigating the propagation of uncertainties in the geometry and material properties to the broadband electrical properties of the standards. For coplanar waveguides used as line standards the analysis based on Monte Carlo simulations demonstrates an up to tenfold reduction in uncertainty depending on the electromagnetic waveguide property we look at.


Langmuir ◽  
2000 ◽  
Vol 16 (17) ◽  
pp. 6801-6808 ◽  
Author(s):  
A.-L. Bernard ◽  
M.-A. Guedeau-Boudeville ◽  
O. Sandre ◽  
S. Palacin ◽  
J.-M. di Meglio ◽  
...  

2013 ◽  
Vol 740-742 ◽  
pp. 733-736 ◽  
Author(s):  
Krystian Król ◽  
Mariusz Sochacki ◽  
Marcin Turek ◽  
Jerzy Żuk ◽  
Henryk M. Przewlocki ◽  
...  

In this article, an influence of nitrogen implantation dosage on SiC MOS structure is analyzed using wide range of nitrogen implantation dose (between ~1013 – 1016). Authors analyzed electrical and material properties of investigated samples using C-V, I-V measurements, Raman spectroscopy, and XPS profiling. It has been shown that surface state trap density is directly connected to implantation damage and thus implantation conditions. Using research results a trap origin at given energy can be concluded.


2018 ◽  
Vol 2018 (HiTEC) ◽  
pp. 000148-000153
Author(s):  
Kenneth P. Dowhower

Abstract The electrical interconnect is an essential component of most electrical system configurations. The ability of the interconnect interface to reliably transmit power and / or data throughout the system is critical to its overall performance. Degradation of the mechanical or electrical properties of the interface can reduce the system performance or in severe cases, make it inoperable. There are several factors which can inhibit the performance of the interconnect, one of most severe is long term exposure to elevated temperatures. This effect can also be accelerated when combined with other severe environmental conditions such as high vibration and physical shock, which are often found in down hole oil and gas well drilling applications. This type of exposure can significantly degrade the essential properties of a reliable electrical interface such as contact resistance, mechanical stability, and electrical isolation. This paper will present options for design features and material properties that can be incorporated into an interconnect design that will mitigate these adverse effects. Specifically, this paper addresses the material properties of the contact interface and its surface treatment, the mechanical and electrical properties of the insulating material, the robustness of the mating features and the contact retention system. Two key features of the contact interface that are discussed are the stability of its electrical resistance and the robustness of its mechanical retention. Long term exposure to high temperatures typically induces stress relaxation in the compliant members of the contact interface that are required to produce a stable, low resistance interface, while allowing for a high level of mate / unmate durability. Stress relaxation can also reduce the mechanical stability of the contact interface where metal or plastic retention features are utilized. In the case of retention through epoxy bonding, imparting thermal stress at the bonding surface can result in loss of adhesion and / or retention. The surface treatment of the contact interface has also been shown to be a contributing factor in its electrical stability in high temperature applications. Typically, the interface is plated with a hard gold over nickel finish, which provides a noble interface that is corrosion resistant, but with the hardness required to withstand many mate / unmate cycles. A small percentage of nickel or cobalt are typically alloyed with the gold to produce the required hardness. In most applications, it has minimal impact on the overall resistance of the contact interface. In high temperature applications, however, it can tend to diffuse through the gold to the contact interface. Since these materials have a higher resistivity, they can negatively affect the resistance of the interface. The impact of this effect is reviewed in this paper. Finally, results of the evaluations on high temperature insulating materials and bonding epoxies are presented in this paper. The mechanical and dielectric stability of the insulating materials and the adhesion properties of the epoxy used for contact retention were the primary concerns for their evaluation. The verification tests that included at temperature exposure were conducted at +260°C to simulate extreme use cases for most down hole applications.


2002 ◽  
Vol 66 (11) ◽  
pp. 2330-2335 ◽  
Author(s):  
Katsuko KAJIYA ◽  
Shigenori KUMAZAWA ◽  
Tsutomu NAKAYAMA

2019 ◽  
Vol 2019 ◽  
pp. 1-8
Author(s):  
Masanori Hirose ◽  
Shigenori Sugisaki ◽  
Keishi Suga ◽  
Hiroshi Umakoshi

A method to detect the L-proline- (L-Pro-) catalyzed Michael addition reaction in model biomembranes has been established, using N-[p(2-benzimidazolyl)phenyl]maleimide and acetone as reactants. The effect of liposome membranes on this reaction was kinetically analyzed using fluorescence spectroscopy. The kinetics of the reaction were different from those of the constituent lipids of the liposomes. Zwitterionic 1,2-dipalmitoyl-sn-glycero-3-phosphocholine liposome, which is in the solid-ordered phase, had a better value of reaction rate, suggesting that the reaction rate constants of this reaction in liposome membrane systems could be regulated by the characteristics of the liposome membrane (i.e., the phase state and surface charge). Based on the results obtained, a plausible model of the L-Pro-catalyzed Michael addition reaction was discussed. The obtained results provide us with an easily detectable method to assess the reactivity of L-Pro in biological systems.


2006 ◽  
Vol 9 (3-4) ◽  
pp. 401-407 ◽  
Author(s):  
Marie Renault ◽  
Valérie Réat ◽  
Masae Sugawara ◽  
Pascal Demange ◽  
Émilie Phez ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document