Optimization of Zinc Sensing Membranes to be Used in Ion-Selective Electrodes for the Determination of Zinc Ion Concentration for Agricultural Applications

2010 ◽  
Vol 117 ◽  
pp. 7-14
Author(s):  
Raja Ram Pradhananga ◽  
A. Nyachhyon ◽  
A.P. Yadav ◽  
Lok Kumar Shrestha ◽  
S. Tandukar

An electrochemical sensor based on the silver sulphide precipitate was fabricated in the laboratory and characterized by x-ray diffraction, SEM equipped with EDAX, and electrochemical techniques. Ion selective electrode (ISE) was found to be sensitive enough to sense the sulphide ion concentration from 10-1 to 10-5 M in alkaline medium. The change in electrode potential per decade change in sulphide ion concentration was found to be 31.5 mV at laboratory temperature indicating adherence of the ion selective electrode to Nernst’s equation. The sensor have been successfully used for the quantitative determination of thiamine in pharmaceutical preparations, hydrogen sulphide in cigarette smoke and determination of solubility products of sparingly soluble silver salts. A trace amount of hydrogen sulphide, a toxic gas, is present in the cigarette smoke. The quantitative estimation of hydrogen sulphide in cigarette smoke is a challenging task to analytical chemist. Hydrogen sulphide in cigarette smoke had been determined by absorbing the cigarette smoke in 0.1 M sodium hydroxide and the resulting solution was analyzed using silver sulphide based ion sensor by standard addition technique using modified Gran plot. The average amounts of hydrogen sulphide produced by a stick of cigarette in 8 different brands of Nepalese cigarette ware found to range from 0.0332 mg to 0.0766 mg. The sensitivity and reliability of these home made ion sensors were excellent and in par with commercial electrodes. For developing countries like Nepal, who can not afford to procure high cost commercial ion selective electrodes, these home made ion sensors are especially appealing since the sensor can be fabricated with ease from the materials that are readily available in the chemistry laboratory and the sensor is quite sensitive and gives reproducible results which are sufficiently accurate for the analysis with ion selective electrodes.


2015 ◽  
Vol 7 (15) ◽  
pp. 6280-6289 ◽  
Author(s):  
Tamer Awad Ali ◽  
Gehad G. Mohamed

Novel carbon paste ion selective electrodes based on the 1,4-bis(6-bromohexyloxy)benzene (BHOB) ionophore were constructed in order to determine the Hg(ii) ion concentration.


2021 ◽  
Vol 25 (3) ◽  
pp. 205-211
Author(s):  
S. D. Tataeva ◽  
◽  
R. Z. Zeynalov ◽  
K. E. Magomedov ◽  
◽  
...  

One of the sensitive and inexpensive methods used for the analysis of water bodies is the ionometry, the development of which is associated with the introduction of new ion-selective electrodes into the practice of potentiometric analysis. An optimized composition of the membrane for the manufacturing of a zinc-selective electrode based on polyvinyl chloride modified with 2-mercaptobenzthiazole (MPVC) is proposed with the following ratio of ingredients (in wt. %): Polyvinyl chloride - 31.7; dioctyl sebacate - 66.3; potassium tetra-p-chlorophenylborate - 0.5; MPVH - 1.5. The working range of pH was established with a minimum potential drift, which was 1.5 - 3. The slope of the electrode function was calculated as 30.1 ± 0.3 mV. According to the dependence of the electrode potential for the selected composition of the membrane on the logarithm of the zinc ion concentration, it was found that the proposed model of the electrode operates in the concentration range of 1∙10-5 - 1∙10-1 mol / L, with a detection limit of 0.65 mg / l. The stabilization time of the potential within 1 mV was 15 - 20 s. The potentiometric coefficients of the selectivity of the zinc selective electrode with respect to various ions have been determined. The conditions for the determination of zinc using the obtained sensor in alloys and wastewater were proposed. The electrode with the membrane based on polyvinyl chloride modified with 2-mercaptobenzthiazole can be used as an alternative to the industrial electrode XC-Zn-001 for the determination of zinc ions in various objects. The obtained experimental data was close in accuracy to the results obtained by the atomic absorption methods, as well as the ionometry using the industrial electrode. In conclusion, the electrode with the membrane based on polyvinyl chloride modified with 2-mercaptobenzthiazole can be used as an alternative to XC-Zn-001.


2016 ◽  
Vol 10 (4s) ◽  
pp. 621-629
Author(s):  
Valentina Pidlisnyuk ◽  
◽  
John Harrington JR ◽  
Yulia Melnyk ◽  
Yuliya Vystavna ◽  
...  

The article focuses on examining the influence of fluctuations in annual precipitation amount on the quality of surface waters. Water quality was estimated with data on BOD, COD and phosphate–ion concentration within five selected regions of Ukraine. Analysis of the precipitation data (1991 – 2010) showed different regional trends. Using the statistics, determination of the interconnection between precipitation amount and water resources quality were done. The obtained regularities and associated uncertainties can be used for prediction of changes in water resource quality and as a guide for future adaptation to possible climate change.


2016 ◽  
Vol 12 (3) ◽  
pp. 177-184 ◽  
Author(s):  
Gamal Abdel-Hafiz Mostafa ◽  
Mohammed Hefnawy ◽  
Mohammed Abounassif ◽  
Amer Alanazi ◽  
Abdulrahman Al-Majed ◽  
...  

Talanta ◽  
2021 ◽  
pp. 122491
Author(s):  
Marek Dębosz ◽  
József Kozma ◽  
Radosław Porada ◽  
Marcin Wieczorek ◽  
Justyna Paluch ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document