scholarly journals Blood pressure changes PVAT function and transcriptome: use of the mid-thoracic aorta coarcted rat

2020 ◽  
Vol 319 (6) ◽  
pp. H1313-H1324
Author(s):  
G. Andres Contreras ◽  
Yongliang Yang ◽  
Emma D Flood ◽  
Hannah Garver ◽  
Sudin Bhattacharya ◽  
...  

A mid-thoracic aorta coarcted rat was created to generate a stable pressure difference above versus below the coarctation ligature. This study determined that the PVAT around the thoracic aorta exposed to a higher pressure has a significantly reduced ability to assist stress relaxation versus that below the ligature and appears to retain the ability to be anticontractile. At the same time, the PVAT around the thoracic aorta exposed to higher pressure had a reduced adipogenic potential versus that below the ligature. Transcriptomics analyses indicated that PVAT below the coarctation showed the greatest number of DEGs with an increased profile of the synaptic neurotransmitter gene network.

2000 ◽  
Vol 39 (02) ◽  
pp. 200-203
Author(s):  
H. Mizuta ◽  
K. Yana

Abstract:This paper proposes a method for decomposing heart rate fluctuations into background, respiratory and blood pressure oriented fluctuations. A signal cancellation scheme using the adaptive RLS algorithm has been introduced for canceling respiration and blood pressure oriented changes in the heart rate fluctuations. The computer simulation confirmed the validity of the proposed method. Then, heart rate fluctuations, instantaneous lung volume and blood pressure changes are simultaneously recorded from eight normal subjects aged 20-24 years. It was shown that after signal decomposition, the power spectrum of the heart rate showed a consistent monotonic 1/fa type pattern. The proposed method enables a clear interpretation of heart rate spectrum removing uncertain large individual variations due to the respiration and blood pressure change.


Author(s):  
Somesh Raju ◽  
Rina Kumari ◽  
Sunita Tiwari ◽  
NS Verma

Background: Interarm systolic blood pressure difference more than 10 mm of Hg is predictor of cardiovascular and metabolic risk. Despite of sufficient physical activity there is high prevalence of obesity in police personal because of stressful working environment. No studies have addressed the significance of interarm pressure difference among them. Therefore, the present study conducted to access the relation of interarm blood pressure difference with obesity in police personnel. Aims and Objective: To estimate the interarm pressure difference in police personal to see its association with their obesity. Material and Method: This cross-sectional observational study done on 245 police workers in PAC, Sitapur, India. Subjects having more than ten years of working experience were included in study. Anthropometric measurements of subject recorded by following standard protocol. Measurement of systolic pressure in both arm recorded simultaneously by mercury sphygmomanometer. Available data analyze and expressed in percentage, mean with SD and chi square test to see the significance of association. Results: According to anthropometric results of subjects 77.14 prcent subjects were having generalised obesity and 82.04 percent of subjects having abdominal obesity. 34.29 percent of subjects showed abnormally high (?10 mmHg) inter-arm systolic blood pressure difference. Both type of obesity showed positive association with blood sugar level but no association with interarm pressure difference. Conclusion: Interarm blood pressure difference is greater in individual having obesity or prolong duration of service. Such subjects are more susceptible to develop coronary artery disease or peripheral arterial disease in future. Early screening can help to detect the vascular events likely to occur in the future Keywords: Body mass index, Waist circumference, Interarm pressure difference, Random blood sugar


2021 ◽  
Vol 10 (14) ◽  
pp. 3075
Author(s):  
Claudia Torino ◽  
Rocco Tripepi ◽  
Maria Carmela Versace ◽  
Antonio Vilasi ◽  
Giovanni Tripepi ◽  
...  

Blood pressure changes upon standing reflect a hemodynamic response, which depends on the baroreflex system and euvolemia. Dysautonomia and fluctuations in blood volume are hallmarks in kidney failure requiring replacement therapy. Orthostatic hypotension has been associated with mortality in hemodialysis patients, but neither this relationship nor the impact of changes in blood pressure has been tested in patients on peritoneal dialysis. We investigated both these relationships in a cohort of 137 PD patients. The response to orthostasis was assessed according to a standardized protocol. Twenty-five patients (18%) had systolic orthostatic hypotension, and 17 patients (12%) had diastolic hypotension. The magnitude of systolic and diastolic BP changes was inversely related to the value of the corresponding supine BP component (r = −0.16, p = 0.056 (systolic) and r = −0.25, p = 0.003 (diastolic), respectively). Orthostatic changes in diastolic, but not in systolic, BP were linearly related to the death risk (HR (1 mmHg reduction): 1.04, 95% CI 1.01–1.07, p = 0.006), and this was also true for CV death (HR: 1.08, 95% CI 1.03–1.12, p = 0.001). The strength of this association was not affected by further data adjustment (p ≤ 0.05). These findings suggest that independent of the formal diagnosis of orthostatic hypotension, even minor orthostatic reductions in diastolic BP bear an excess death risk in this population.


2016 ◽  
Vol 34 (Supplement 1) ◽  
pp. e121
Author(s):  
Fernando Garcia ◽  
Beatriz Fidale ◽  
Sebastião Ferreira-Filho

Sign in / Sign up

Export Citation Format

Share Document