Dynamics of cardiac output and systolic time intervals in supine and upright exercise

1983 ◽  
Vol 55 (6) ◽  
pp. 1674-1681 ◽  
Author(s):  
Y. Miyamoto ◽  
J. Higuchi ◽  
Y. Abe ◽  
T. Hiura ◽  
Y. Nakazono ◽  
...  

Transient and steady-state responses of stroke volume (SV), heart rate (HR), cardiac output (Q), left ventricular ejection time (LVET), preejection period (PEP), and the ratio of LVET to PEP during bicycle exercises of 50 and 100 W were studied in four healthy male subjects in supine and upright postures. A computer-based system in which impedance cardiography was incorporated served to determine the above parameters on a 10-s interval basis. SV remained almost unchanged in response to exercises in a supine posture, whereas it increased significantly in an upright posture, although the individual differences among subjects were found to be large. The half-response times of variables to a step work load were determined. An approximate accordance was observed among the response times for HR, Q, and LVET/PEP. There was an inverse relationship between LVET and HR, the slope of which was found to be steeper in the supine posture than in the upright posture, reflecting the difference between the SV responses in both postures. LVET fell shortly after the cessation of exercise despite the decreasing HR. Inasmuch as the paradoxical reduction of LVET was also found in the case where SV remained unchanged in response to exercise, no changes in SV can be the cause thereof. Thus, a transient increase in ejection rate, which is due to either the increased myocardial contractility or decreased peripheral vascular resistance, may be responsible for the phenomenon.

1978 ◽  
Vol 44 (1) ◽  
pp. 55-58 ◽  
Author(s):  
L. A. Wolfe ◽  
D. A. Cunningham ◽  
G. M. Davis ◽  
P. A. Rechnitzer

Externally recorded systolic time intervals (STI's), indirect (CO2 re-breathing) cardiac output, and auscultatory blood pressures were measured during upright bicycle ergometer work in 20 healthy men, aged 24–56 yr. The subjects were studied on 2 separate days at steady-state work loads chosen to represent light (mean heart rate (HR) = 96 beats.min-1), moderate (HR = 118 beats.min-1) and heavy (HR = 147 beats.min-1) exercise. In addition to determinations of cardiac output, systolic time intervals, and blood pressure, the individual's mean systolic ejection rate (stroke volume/left ventricular ejection time) was calculated as a measure of left ventricular function. In general, heart-rate-corrected STI's were found to be reliable and reproducible. Reliability coefficients for total electromechanical systole and left ventricular ejection time ranged from 0.93 to 0.96 while those for the preejection period and its subcomponents were between 0.63 and 0.88. The reliability of cardiac output, stroke volume, mean systolic ejection rate, and systolic blood pressure was also considered to be acceptable but tended to be higher during moderate and heavy work (r = 0.85–0.95) compared to light exercise (r = 0.60–0.83).


1963 ◽  
Vol 18 (5) ◽  
pp. 919-923 ◽  
Author(s):  
Arnold M. Weissler ◽  
Leonard C. Harris ◽  
George D. White

The present studies were undertaken in an attempt to formulate an accurate expression of the relationship between the duration of left ventricular ejection and heart rate in man. On the basis of regression equations relating the duration of left ventricular ejection and heart rate in normal individuals, the index LVET + .0016 HR was derived and tested in normal adults and prepubertal children. The left ventricular ejection time index (ETI) remained constant and reproducible over the range of heart rate from 50 to 150 and yielded more consistent values in this range of heart rate than did previously derived equations. A slight but significantly higher value of the ETI was present in the adult females when compared to the adult males, while no significant difference according to sex was apparent in the children. A decrease in ETI was found when cardiac output was diminished in normal individuals during 60° head-up tilt and in patients with congestive heart failure. Of note was the finding of a significant correlation between the level of the ETI and the cardiac output in these situations. Submitted on December 13, 1962


2005 ◽  
Vol 19 (3) ◽  
pp. 195-203 ◽  
Author(s):  
Jennifer J. McGrath ◽  
William H. O'Brien ◽  
Hilary J. Hassinger ◽  
Purvi Shah

Abstract. Although band and spot electrodes have been compared in prior research, they have not been evaluated (a) at identical anatomical locations, (b) during a single laboratory session, (c) with measures taken in close temporal proximity, (d) using a single impedance cardiograph unit, or (e) using sufficiently powerful statistical tests. Thirty-one healthy young adults completed a psychophysiological assessment which consisted of baseline, mental arithmetic stressor, and recovery conditions. Data from spot and band electrodes were collected by alternating between electrode types every minute of the experiment. Correlations between spot and band electrodes at absolute levels of all cardiovascular measures (cardiac output, impedance derivative, basal impedance level, Heather index, heart rate, left ventricular ejection time, pre-ejection period, stroke volume) were of high magnitude (ravg = .78), while the correlations for difference scores were lower (ravg = .50). Analyses of mean levels indicated spot electrodes yielded significantly lower values for the impedance derivative, Heather index, and basal impedance, and higher values for cardiac output and stroke volume, than band electrodes. The advantages and disadvantages associated with spot and band electrode configurations, as well as their use in ambulatory recording, are discussed.


2013 ◽  
Vol 13 (3) ◽  
pp. 157-164 ◽  
Author(s):  
E. Pinheiro ◽  
O. Postolache ◽  
P. Girão

Impedance cardiography is a technique developed with the intent of monitoring cardiac output. By inspecting a few properties of the obtained signal (impedance cardiogram (ICG), the left ventricular ejection time can be derived with certainty, and an estimate of cardiac output is available. This signal is nowadays used in non-invasive monitoring, requiring the placement of electrodes over the subject’s skin, either ECG-type or in the form of encircling bands. The work here reported describes the implementation steps and the results obtained when embedding the ICG circuitry in a wheelchair’s backrest. The subject is seated normally, is normally dressed, and is completely unaware that monitoring is taking place. That means that the variation of tenths of ohm produced due to the cardiac cycle has to be detected with electrodes having substantial coupling impedance. Contactless ICG with embedded sensors was developed and tested on fourteen healthy subjects. The signal was always acquired, although respiratory activity is also important, constituting a noteworthy innovation in the area.


1978 ◽  
Vol 87 (3) ◽  
pp. 507-515 ◽  
Author(s):  
J. Chakravarty ◽  
A. R. Guansing ◽  
S. Chakravarty ◽  
C. V. Hughes

ABSTRACT Systolic time intervals consisting of indices of electromechanical systole (QS2-I), left ventricular ejection time (LVET-I) and pre-ejection period (PEP-I) were calculated serially during therapy in 12 euthyroid, 9 hypothyroid and 9 hyperthyroid individuals. These parameters were analyzed sequentially together with the changes in serum thyroxine (T4), triiodothyronine (T3) and thyrotrophin (TSH) in order to determine the sensitivity of these non-invasive procedures in monitoring peripheral thyroid hormone effect. The results are expreseed in mean ± sem. QS2-I (506.3 ± 8.2 ms) and PEP-I (102.9 ± 4.2) were shortened (P < 0.02 and P < 0.001, respectively) in hyperthyroidism and prolonged (579.3 ± 7.3 and 169.6 ± 3.6 ms) in hypothyroidism (P < 0.01 and P < 0.001, respectively) compared to euthyroid controls (538.1 ± 8.8 and 130.3 ± 5.3 ms), while LVET-I did not change significantly in either condition. Simultaneous determinations of circulating T4, T3 and TSH showed changes appropriate to both hypo- and hyperthyroid states. In 2 patients with T3-thyrotoxicosis, PEP-I was decreased to an average of 103.1 ms, while in 2 patients with compensated hypothyroidism (normal T4 but elevated TSH) this was prolonged to 163.7 ms (average) compared to euthyroid controls. During treatment the hypothyroid group showed significant sequential correlation of TSH and PEP-I. In the hyperthyroid individuals, PEP-I correlated significantly with T4 and T3. PEP-I may be a useful, sensitive, quantitative biologic indicator of thyroid hormone effect on myocardial function.


2017 ◽  
Vol 42 (8) ◽  
pp. 834-840 ◽  
Author(s):  
Scott Michael ◽  
Ollie Jay ◽  
Kenneth S. Graham ◽  
Glen M. Davis

Systolic time intervals (STIs) provide noninvasive insights into cardiac sympathetic neural activity (cSNA). As the effect of exercise intensity on postexercise STI recovery is unclear, this study investigated the STI recovery profile after different exercise intensities. Eleven healthy males cycled for 8 min at 3 separate intensities: LOW (40%–45%), MOD (75%–80%), and HIGH (90%–95%) of heart-rate (HR) reserve. Bio-impedance cardiography was used to assess STIs – primarily pre-ejection period (PEP; inversely correlated with cSNA), as well as left ventricular ejection time (LVET) and PEP:LVET – during 10 min seated recovery immediately postexercise. Heart-rate variability (HRV), i.e., natural-logarithm of root mean square of successive differences (Ln-RMSSD), was calculated as an index of cardiac parasympathetic neural activity (cPNA). Higher preceding exercise intensity elicited a slower recovery of HR and Ln-RMSSD (p < 0.001), and these measures did not return to baseline by 10 min following any intensity (p ≤ 0.009). Recovery of STIs was also slower following higher intensity exercise (p ≤ 0.002). By 30 s postexercise, higher preceding intensity resulted in a lower PEP (98 ± 14 ms, 75 ± 6 ms, 66 ± 5 ms for LOW, MOD, and HIGH, respectively, p < 0.001). PEP recovered to baseline (143 ± 11 ms) by 5 min following LOW (139 ± 13 ms, p = 0.590) and by 10 min following MOD (145 ± 17 ms, p = 0.602), but was still suppressed at 10 min following HIGH (123 ± 21 ms, p = 0.012). Higher preceding exercise intensity attenuated the recovery of indices for cSNA (from STIs) and cPNA (from HRV) in a graded dose–response fashion. While exercise intensity must be considered, acute recovery may be a valuable period during which to concurrently monitor these noninvasive indices, to identify potentially abnormal cardiac autonomic responses.


1992 ◽  
Vol 4 (1) ◽  
pp. 85-93 ◽  
Author(s):  
Barbara N. Campaigne ◽  
Kyle W. Landt ◽  
Frederick W. James ◽  
Joan Reimar ◽  
Wayne Mays ◽  
...  

Systolic time intervals (STI) were measured before and after exercise in 18 diabetic adolescents (D) and 18 age- and sex-matched nondiabetic controls (C). At similar heart rates, pre-exercise pre-ejection period (PEP) and left ventricular ejection time (LVET) were significantly shorter in D compared to C (p<0.05). There was no difference between the two groups in the PEP/LVET ratio. Following exercise there were no differences in STIs between groups. However, the change in PEP and LVET from pre- to postexercise was significantly less in D compared to C (delta PEP 38 vs. 53±3 msec, p<0.01; delta LVET 120 vs. 134±4 msec, p<0.05). These data suggest a hypercontractile state at rest in D and a blunted response to exercise when compared to C. This study provides data that may be relevant to the early identification of individuals at risk for premature diabetic cardiomyopathy.


Sensors ◽  
2018 ◽  
Vol 18 (9) ◽  
pp. 3036 ◽  
Author(s):  
Shing-Hong Liu ◽  
Jia-Jung Wang ◽  
Chun-Hung Su ◽  
Da-Chuan Cheng

Cardiac stroke volume (SV) is an essential hemodynamic indicator that can be used to assess whether the pump function of the heart is normal. Non-invasive SV measurement is currently performed using the impedance cardiography (ICG). In this technology, left ventricular ejection time (LVET) is an important parameter which can be determined from the ICG signals. However, the ICG signals are inherently susceptible to artificial noise interference, which leads to an inaccurate LVET measurement and then yields an error in the calculation of SV. Therefore, the goal of the study was to measure LVETs using both the transmission and reflection photoplethysmography (PPG), and to assess whether the measured LVET was more accurate by the PPG signal than the ICG signal. The LVET measured by the phonocardiography (PCG) was used as the standard for comparing with those by the ICG and PPG. The study recruited ten subjects whose LVETs were simultaneously measured by the ICG using four electrodes, the reflection PPG using neck sensors (PPGneck) and the transmission PPG using finger sensors (PPGfinger). In each subject, ten LVETs were obtained from ten heartbeats selected properly from one-minute recording. The differences of the measured LVETs between the PCG and one of the ICG, PPGneck and PPGfinger were −68.2 ± 148.6 ms, 4.8 ± 86.5 ms and −7.0 ± 107.5 ms, respectively. As compared with the PCG, both the ICG and PPGfinger underestimated but the PPGneck overestimated the LVETs. Furthermore, the measured LVET by the PPGneck was the closest to that by the PCG. Therefore, the PPGneck may be employed to improve the LVET measurement in applying the ICG for continuous monitoring of SV in clinical settings.


1980 ◽  
Vol 238 (3) ◽  
pp. H355-H359 ◽  
Author(s):  
Y. Nakamura ◽  
B. G. Haffty ◽  
D. H. Spodick ◽  
D. Paladino ◽  
K. Moreau ◽  
...  

The ear densitograph displacement pulse derivative (dD/dtear) is the analog of the arterial pressure derivative (dP/dt) and behaves comparably under a variety of cardiocirculatory challenges. Technical reliability and uniform application of the transducer are advantages that make it ideal for intrasubject monitoring. With atrial fibrillation as a model of functional variability in eight subjects, peak dD/dtear (P) tracked echocardiographic stroke volume, ejection fraction, ejection rate, and velocity of circumferential fiber shortening quite closely with the exception of some values in three subjects, two of whom had mitral regurgitation and one paradoxic septal movement. In all subjects, P showed good to excellent correlations with cycle length, preejection period (PEP), LVET (left ventricular ejection time), and PEP/LVET. The method appears to be ideally suited to intrasubject monitoring for changing ventricular function.


Sign in / Sign up

Export Citation Format

Share Document