Diaphragmatic and ventilatory responses to alveolar hypoxia and hypercapnia in conscious kittens

1992 ◽  
Vol 72 (1) ◽  
pp. 203-210 ◽  
Author(s):  
M. Bonora ◽  
M. Boule ◽  
H. Gautier

Ventilation and electromyographic (EMG) activity of the diaphragm were recorded in unanesthetized kittens 2 and 10 wk of age during normoxia, hypercapnia (2 and 4% CO2), and hypoxia (12 and 10% O2). We measured integrated diaphragmatic EMG activity at end inspiration (DIAI) and end expiration (DIAE); the difference (DIAI-E), which represents the phasic change of the diaphragmatic activity, was considered responsible for a given tidal volume (VT). During hypercapnia, the 2-wk-old kittens increased minute ventilation (V) by increases in both VT and respiratory frequency (f), whereas the 10-wk-old kittens increased V primarily by an increase in VT. At both ages, DIAI and DIAI-E increased during hypercapnia, whereas DIAE did not change significantly. During hypoxia, in the young kittens, V and VT decreased while f increased markedly; in the older kittens, V, VT, and f did not change significantly. In kittens of both ages, DIAI increased during hypoxia; because diaphragmatic activity persisted into expiration, DIAE also increased. DIAI-E, as well as VT, was decreased in the young kittens, whereas in the older ones DIAI-E was slightly increased despite an unchanged VT. Finally, the ventilatory and diaphragmatic response to hypoxia changes with maturation in contrast to the response to hypercapnia. It is concluded that 1) the hypoxia-induced reduction of VT may result from prolongation of diaphragmatic activity into expiration, inasmuch as it induces a reduction of the phasic change of the diaphragmatic activity, and 2) because DIAI-E indirectly reflects central inspiratory output, a central mechanism should be involved in the reduced VT and V in response to hypoxia in newborns.

2004 ◽  
Vol 97 (4) ◽  
pp. 1401-1407 ◽  
Author(s):  
Masahiko Izumizaki ◽  
Mieczyslaw Pokorski ◽  
Ikuo Homma

We examined the effects of carotid body denervation on ventilatory responses to normoxia (21% O2 in N2 for 240 s), hypoxic hypoxia (10 and 15% O2 in N2 for 90 and 120 s, respectively), and hyperoxic hypercapnia (5% CO2 in O2 for 240 s) in the spontaneously breathing urethane-anesthetized mouse. Respiratory measurements were made with a whole body, single-chamber plethysmograph before and after cutting both carotid sinus nerves. Baseline measurements in air showed that carotid body denervation was accompanied by lower minute ventilation with a reduction in respiratory frequency. On the basis of measurements with an open-circuit system, no significant differences in O2 consumption or CO2 production before and after chemodenervation were found. During both levels of hypoxia, animals with intact sinus nerves had increased respiratory frequency, tidal volume, and minute ventilation; however, after chemodenervation, animals experienced a drop in respiratory frequency and ventilatory depression. Tidal volume responses during 15% hypoxia were similar before and after carotid body denervation; during 10% hypoxia in chemodenervated animals, there was a sudden increase in tidal volume with an increase in the rate of inspiration, suggesting that gasping occurred. During hyperoxic hypercapnia, ventilatory responses were lower with a smaller tidal volume after chemodenervation than before. We conclude that the carotid bodies are essential for maintaining ventilation during eupnea, hypoxia, and hypercapnia in the anesthetized mouse.


1988 ◽  
Vol 64 (6) ◽  
pp. 2544-2551 ◽  
Author(s):  
H. Rigatto ◽  
C. Wiebe ◽  
C. Rigatto ◽  
D. S. Lee ◽  
D. Cates

We studied the ventilatory response to hypoxia in 11 unanesthetized newborn kittens (n = 54) between 2 and 36 days of age by use of a flow-through system. During quiet sleep, with a decrease in inspired O2 fraction from 21 to 10%, minute ventilation increased from 0.828 +/- 0.029 to 1.166 +/- 0.047 l.min-1.kg-1 (P less than 0.001) and then decreased to 0.929 +/- 0.043 by 10 min of hypoxia. The late decrease in ventilation during hypoxia was related to a decrease in tidal volume (P less than 0.001). Respiratory frequency increased from 47 +/- 1 to 56 +/- 2 breaths/min, and integrated diaphragmatic activity increased from 14.9 +/- 0.9 to 20.2 +/- 1.4 arbitrary units; both remained elevated during hypoxia (P less than 0.001). Younger kittens (less than 10 days) had a greater decrease in ventilation than older kittens. These results suggest that the late decrease in ventilation during hypoxia in the newborn kitten is not central but is due to a peripheral mechanism located in the lungs or respiratory pump and affecting tidal volume primarily. We speculate that either pulmonary bronchoconstriction or mechanical uncoupling of diaphragm and chest wall may be involved.


PEDIATRICS ◽  
1995 ◽  
Vol 95 (6) ◽  
pp. 864-867
Author(s):  
Janet G. Wingkun ◽  
Janet S. Knisely ◽  
Sidney H. Schnoll ◽  
Gary R. Gutcher

Objective. To determine whether there is a demonstrable abnormality in control of breathing in infants of substance-abusing mothers during the first few days of life. Methods. We enrolled 12 drug-free control infants and 12 infants of substance abusing mothers (ISAMs). These infants experienced otherwise uncomplicated term pregnancies and deliveries. The infants were assigned to a group based on the results of maternal histories and maternal and infant urine toxicology screens. Studies were performed during quiet sleep during the first few days of life. We measured heart rate, oxygen saturations via a pulse oximeter, end-tidal carbon dioxide (ET-CO2) level, respiratory rate, tidal volume, and airflow. The chemoreceptor response was assessed by measuring minute ventilation and the ET-CO2 level after 5 minutes of breathing either room air or 4% carbon dioxide. Results. The gestational ages by obstetrical dating and examination of the infants were not different, although birth weights and birth lengths were lower in the group of ISAMs. Other demographic data were not different, and there were no differences in the infants' median ages at the time of study or in maternal use of tobacco and alcohol. The two groups had comparable baseline (room air) ET-CO2 levels, respiratory rates, tidal volumes, and minute ventilation. When compared with the group of ISAMs, the drug-free group had markedly increased tidal volume and minute ventilation on exposure to 4% carbon dioxide. These increases accounted for the difference in sensitivity to carbon dioxide, calculated as the change in minute ventilation per unit change in ET-CO2 (milliliters per kg/min per mm Hg). The sensitivity to carbon dioxide of control infants was 48.66 ± 7.14 (mean ± SE), whereas that of ISAMs was 16.28 ± 3.14. Conclusions. These data suggest that ISAMs are relatively insensitive to challenge by carbon dioxide during the first few days of life. We speculate that this reflects an impairment of the chemoreceptor response.


2019 ◽  
Vol 126 (1) ◽  
pp. 111-123 ◽  
Author(s):  
Kun-Ze Lee

The present study was designed to investigate breathing patterns across the sleep-wake state following a high cervical spinal injury in rats. The breathing patterns (e.g., respiratory frequency, tidal volume, and minute ventilation), neck electromyogram, and electroencephalography of unanesthetized adult male rats were measured at the acute (i.e., 1 day), subchronic (i.e., 2 wk), and/or chronic (i.e., 6 wk) injured stages after unilateral contusion of the second cervical spinal cord. Cervical spinal cord injury caused a long-term reduction in the tidal volume but did not influence the sleep-wake cycle duration. The minute ventilation during sleep was usually lower than that during the wake period in uninjured animals due to a decrease in respiratory frequency. However, this sleep-induced reduction in respiratory frequency was not observed in contused animals at the acute injured stage. By contrast, the tidal volume was significantly lower during sleep in contused animals but not uninjured animals from the acute to the chronic injured stage. Moreover, the frequency of sigh and postsigh apnea was elevated in acutely contused animals. These results indicated that high cervical spinal contusion is associated with exacerbated sleep-induced attenuation of the tidal volume and higher occurrence of sleep apnea, which may be detrimental to respiratory functional recovery after cervical spinal cord injury. NEW & NOTEWORTHY Cervical spinal injury is usually associated with sleep-disordered breathing. The present study investigated breathing patterns across sleep-wake state following cervical spinal injury in the rat. Unilateral cervical spinal contusion significantly impacted sleep-induced alteration of breathing patterns, showing a blunted frequency response and exacerbated attenuated tidal volume and occurrence of sleep apnea. The result enables us to investigate effects of cervical spinal injury on the pathogenesis of sleep-disordered breathing and evaluate potential therapies to improve respiration.


1994 ◽  
Vol 77 (6) ◽  
pp. 2703-2708 ◽  
Author(s):  
H. Burnet ◽  
M. Bascou-Bussac ◽  
C. Martin ◽  
Y. Jammes

In mechanically ventilated patients the natural gas-conditioning process of the upper airways is bypassed by the use of an endotracheal tube or a tracheostomy. We hypothesized that under these conditions the breathing pattern may greatly influence the convective respiratory heat loss (Cr). Cr values were computed from minute ventilation (VE) and inspiratory and expiratory gas temperatures, which were measured in six patients under mechanical ventilation for the management of cranial trauma. In each patient the effects of 11–20 different breathing patterns were investigated. Relationships between Cr and VE and between combined tidal volume and respiratory frequency were obtained by simple and multiple linear regression methods, respectively. Comparison of the standard errors of estimate indicated that multiple linear regression gives the best fit. Thus, Cr was highly dependent on the breathing pattern and was not related only to VE. For the same VE value, Cr was higher when VE was achieved with high tidal volume and low respiratory frequency. These data are consistent with previous studies in which thermal exchanges through the upper airways were taxed by hyperventilation of frigid air.


1984 ◽  
Vol 56 (1) ◽  
pp. 12-17 ◽  
Author(s):  
C. E. Blanco ◽  
M. A. Hanson ◽  
P. Johnson ◽  
H. Rigatto

In 19 pentobarbital sodium-anesthetized kittens aged 5–34 days, inspired O2 was reduced from 21 to 6–512%. Respiratory frequency (f) and tidal volume (VT) increased within 30 s. Over 5 min f fell to about 60% below control; VT usually fell but remained above control. Arterial pressure fell in 80% of trials, sometimes before f fell. Arterial CO2 was below control, but raising inspired CO2 to keep expired CO2 at control did not prevent the fall in f and VT. The relation between VT and esophageal pressure or diaphragm electromyogram (EMG) did not change consistently, nor was the ratio of high to low frequencies in the diaphragm EMG altered. Carotid chemoreceptor discharge increased within 15 s, and at 5 min it was much above control. We conclude that the change in the breathing pattern in hypoxia is probably due to the activation of a central mechanism.


2002 ◽  
Vol 93 (4) ◽  
pp. 1515-1526 ◽  
Author(s):  
Cheng-Li Que ◽  
Christof Kolmaga ◽  
Louis-Gilles Durand ◽  
Suzanne M. Kelly ◽  
Peter T. Macklem

We measured tracheal flow from tracheal sounds to estimate tidal volume, minute ventilation (V˙i), respiratory frequency, mean inspiratory flow (Vt/Ti), and duty cycle (Ti/Ttot). In 11 normal subjects, 3 patients with unstable airway obstruction, and 3 stable asthmatic patients, we measured tracheal sounds and flow twice: first to derive flow-sound relationships and second to obtain flow-volume relationships from the sound signal. The flow-volume relationship was compared with pneumotach-derived volume. When subjects were seated, facing forward and with neck rotation, flexion, and standing, flow-volume relationship was within 15% of pneumotach-derived volume. Error increased with neck extension and while supine. We then measured ventilation without mouthpiece or nose clip from tracheal sounds during quiet breathing for up to 30 min. Normal results ± SD revealed tidal volume = 0.37 ± 0.065 liter, respiratory frequency = 19.3 ± 3.5 breaths/min, V˙i = 6.9 ± 1.2 l/min, Vt/Ti = 0.31 ± 0.06 l/s, and Ti/Ttot = 0.37 ± 0.04. Unstable airway obstruction had large V˙i due to increased Vt/Ti. With the exception of Ti/Ttot, variations in ventilatory parameters were closer to log normal than normal distributions and tended to be greater in patients. We conclude that phonospirometry measures ventilation reasonably accurately without mouthpiece, nose clip, or rigid postural constraints.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Paulina M. Getsy ◽  
Sripriya Sundararajan ◽  
Walter J. May ◽  
Graham C. von Schill ◽  
Dylan K. McLaughlin ◽  
...  

AbstractThe roles of endothelial nitric oxide synthase (eNOS) in the ventilatory responses during and after a hypercapnic gas challenge (HCC, 5% CO2, 21% O2, 74% N2) were assessed in freely-moving female and male wild-type (WT) C57BL6 mice and eNOS knock-out (eNOS-/-) mice of C57BL6 background using whole body plethysmography. HCC elicited an array of ventilatory responses that were similar in male and female WT mice, such as increases in breathing frequency (with falls in inspiratory and expiratory times), and increases in tidal volume, minute ventilation, peak inspiratory and expiratory flows, and inspiratory and expiratory drives. eNOS-/- male mice had smaller increases in minute ventilation, peak inspiratory flow and inspiratory drive, and smaller decreases in inspiratory time than WT males. Ventilatory responses in female eNOS-/- mice were similar to those in female WT mice. The ventilatory excitatory phase upon return to room-air was similar in both male and female WT mice. However, the post-HCC increases in frequency of breathing (with decreases in inspiratory times), and increases in tidal volume, minute ventilation, inspiratory drive (i.e., tidal volume/inspiratory time) and expiratory drive (i.e., tidal volume/expiratory time), and peak inspiratory and expiratory flows in male eNOS-/- mice were smaller than in male WT mice. In contrast, the post-HCC responses in female eNOS-/- mice were equal to those of the female WT mice. These findings provide the first evidence that the loss of eNOS affects the ventilatory responses during and after HCC in male C57BL6 mice, whereas female C57BL6 mice can compensate for the loss of eNOS, at least in respect to triggering ventilatory responses to HCC.


1989 ◽  
Vol 67 (6) ◽  
pp. 2357-2368 ◽  
Author(s):  
A. Torres ◽  
W. R. Kimball ◽  
J. Qvist ◽  
K. Stanek ◽  
R. M. Kacmarek ◽  
...  

Through a right thoracotomy in seven sheep we chronically implanted sonomicrometry crystals and electromyographic electrodes in the costal and crural diaphragmatic regions. Awake sheep were studied during recovery for 4-6 wk, both during quiet breathing (QB) and during CO2 rebreathing. Tidal volume, respiratory frequency, and esophageal and gastric pressures were studied before and after surgery. Normalized resting length (LFRC) was significantly decreased for the costal segment on postoperative day 1 compared with postoperative day 28. Fractional costal shortening both during QB and at 10% end-tidal CO2 (ETCO2) increased significantly from postoperative days 1 to 28, whereas crural shortening did not change during QB but progressively increased at 10% ETCO2. Maximal costal shortening during electrophrenic stimulation was constant at 40% LFRC during recovery, although maximal crural shortening increased from 23 to 32% LFRC. Minute ventilation, tidal volume, and transdiaphragmatic pressure at 10% ETCO2 increased progressively after thoracotomy until postoperative day 28. Our results suggest there is profound diaphragmatic inhibition after thoracotomy and crystal implantation in sheep that requires at least 3-4 wk for stable recovery.


PEDIATRICS ◽  
1983 ◽  
Vol 71 (4) ◽  
pp. 634-638
Author(s):  
Manuel Durand ◽  
Ellen McCann ◽  
June P. Brady

The effect of continuous positive airway pressure (CPAP) on the ventilatory response to CO2 in newborn infants is unknown. The CO2 response to 4% CO2 in air was studied in nine preterm infants without lung disease before and during administration of CPAP (4 to 5 cm H2O) delivered by face mask. Minute ventilation, tidal volume, respiratory frequency, and end-tidal Pco2 were measured, and the slope and intercept of the CO2 response were calculated. Respiratory pattern and changes in oxygenation were also analyzed by measuring inspiratory and expiratory time, mean inspiratory flow, mean expiratory flow, effective respiratory timing, endtidal Po2, and transcutaneous Po2. CPAP significantly decreased minute ventilation from 278.7 to 197.6 mL/mm/kg (P < .001). Tidal volume and respiratory frequency were also significantly decreased. The slope of the CO2 response during CPAP was not significantly different from the slope before CPAP (36 v 33 mL/min/kg/mm Hg, P > .1), but the intercept was shifted to the right (P < .001). The decrease in respiratory frequency was primarily due to a prolongation of expiratory time (P < .05). In addition, transcutaneous Po2 increased during administration of CPAP (P < .001). These findings indicate that: (1) CPAP significantly decreases ventilation in preterm infants without lung disease, affecting both tidal volume and respiratory frequency; (2) CPAP does not appreciably alter the ventilatory response to CO2; (3) the changes in respiratory frequency are primarily accounted for by a prolongation of expiratory time; (4) CPAP improves oxygenation.


Sign in / Sign up

Export Citation Format

Share Document