Assessment of physical activity in youth

2008 ◽  
Vol 105 (3) ◽  
pp. 977-987 ◽  
Author(s):  
Kirsten Corder ◽  
Ulf Ekelund ◽  
Rebekah M. Steele ◽  
Nicholas J. Wareham ◽  
Søren Brage

Despite much progress with physical activity assessment, the limitations concerning the accurate measurement of physical activity are often amplified in young people due to the cognitive, physiological, and biomechanical changes that occur during natural growth as well as a more intermittent pattern of habitual physical activity in youth compared with adults. This mini-review describes and compares methods to assess habitual physical activity in youth and discusses main issues regarding the use and interpretation of data collected with these techniques. Self-report instruments and movement sensing are currently the most frequently used methods for the assessment of physical activity in epidemiological research; others include heart rate monitoring and multisensor systems. Habitual energy expenditure can be estimated from these input measures with varying degree of uncertainty. Nonlinear modeling techniques, using accelerometry perhaps in combination with physiological parameters like heart rate or temperature, have the greatest potential for increasing the prediction accuracy of habitual physical activity energy expenditure. Although multisensor systems may be more accurate, this must be balanced against feasibility, a balance that shifts with technological and scientific advances and should be considered at the beginning of every new study.

2013 ◽  
Vol 177 (6) ◽  
pp. 576-585 ◽  
Author(s):  
M. L. Neuhouser ◽  
C. Di ◽  
L. F. Tinker ◽  
C. Thomson ◽  
B. Sternfeld ◽  
...  

2017 ◽  
Vol 27 (5) ◽  
pp. 467-474 ◽  
Author(s):  
Jorge Cañete García-Prieto ◽  
Vicente Martinez-Vizcaino ◽  
Antonio García-Hermoso ◽  
Mairena Sánchez-López ◽  
Natalia Arias-Palencia ◽  
...  

The aim of this study was to examine the energy expenditure (EE) measured using indirect calorimetry (IC) during playground games and to assess the validity of heart rate (HR) and accelerometry counts as indirect indicators of EE in children´s physical activity games. 32 primary school children (9.9 ± 0.6 years old, 19.8 ± 4.9 kg · m-2 BMI and 37.6 ± 7.2 ml · kg-1 · min-1 VO2max). Indirect calorimetry (IC), accelerometry and HR data were simultaneously collected for each child during a 90 min session of 30 playground games. Thirty-eight sessions were recorded in 32 different children. Each game was recorded at least in three occasions in other three children. The intersubject coefficient of variation within a game was 27% for IC, 37% for accelerometry and 13% for HR. The overall mean EE in the games was 4.2 ± 1.4 kcals · min-1 per game, totaling to 375 ± 122 kcals/per 90 min/session. The correlation coefficient between indirect calorimetry and accelerometer counts was 0.48 (p = .026) for endurance games and 0.21 (p = .574) for strength games. The correlation coefficient between indirect calorimetry and HR was 0.71 (p = .032) for endurance games and 0.48 (p = .026) for strength games. Our data indicate that both accelerometer and HR monitors are useful devices for estimating EE during endurance games, but only HR monitors estimates are accurate for endurance games.


2003 ◽  
Vol 28 (2) ◽  
pp. 190-203 ◽  
Author(s):  
Alexandre Melin ◽  
Philippe Obert ◽  
Pierre Bonnet ◽  
Daniel Courteix

In order to assess possible influences of socioeconomic status and gender on habitual physical activity (HPA) of prepubertal French children, daily heart rate was 24-hr-monitored in 65 normal subjects for 2 days in the same school week. HPA was evaluated as the mean daily time spent at heart rates greater than 140 bpm (tFC > 140), 160 bpm (tFC > 160), 50% (tFC > 50%), and 70% (tFC > 70%) of the heart rate reserve. An effect of socioeconomic status (determined by questionnaire) was found in boys, with HPA being greater in the underprivileged ones (tFC > 140: 51.8 ± 30.1 vs 33.0 ± 14.1 min, p < .05; tFC > 160: 22.7 ± 16.6 vs 11.1 ± 7.4 min, p < .05; tFC > 50%: 61.4 ± 33.5 vs 46.5 ± 17.1 min, p < .06; tFC > 70%: 20.1 ± 15.2 vs 10.6 ± 7.1, p < .05). Boys were more active than girls, but only in the underprivileged group (tFC > 140: 51.8 ± 30.1 vs 32.8 ± 26.0 min, tFC > 160: 22.7 ± 16.6 vs 9.9 ± 8.2 min, p < .05; tFC > 50%: 61.4 ± 33.5 vs 37.4 ± 23.8 min, p < .05; tFC > 70%: 20.1 ± 15.2 vs 8.1 ± 6.3, p < .05). Cultural factors could be involved in these results. Key words: habitual physical activity, heart rate, heart rate meter, gender, energy expenditure


BMJ Open ◽  
2017 ◽  
Vol 7 (2) ◽  
pp. e012655 ◽  
Author(s):  
Júlia Caetano Martins ◽  
Larissa Tavares Aguiar ◽  
Sylvie Nadeau ◽  
Aline Alvim Scianni ◽  
Luci Fuscaldi Teixeira-Salmela ◽  
...  

1998 ◽  
Vol 30 (Supplement) ◽  
pp. 56 ◽  
Author(s):  
C. A. Burks ◽  
B. J. Sharkey ◽  
S. A. Tysk ◽  
T. W. Zderic ◽  
S. L. Johnson ◽  
...  

1998 ◽  
Vol 87 (1) ◽  
pp. 315-320
Author(s):  
Avery D. Faigenbaum ◽  
Joseph Ciccolo ◽  
Joseph R. Libonati

Preliminary assessment was made concerning perceptions of the newly developed bean-rate guide, devised as an educational tool to promote physical activity. Unlike the traditional target heart-rate chart, the heart-rate guide illustrates the value of low to moderate intensity physical activity. Following a brief lecture about the Surgeon General's report on physical activity and health and the usefulness of heart-rate charts and guides, 120 college students ( M age 21.5 ± 2.8 yr.) completed a self-report survey consisting of statements regarding their use of target heart rates during exercise and their perceptions of the new heart-rate guide as compared to the traditional heart-rate chart. 83% of the subjects reported that the new guide better illustrated the findings from the Surgeon General's report, 5% reported no difference between the guide and the chart, and 12% reported that the chart better illustrated the report's findings ( p<.01). 48% never measure their heart rates when they exercise, 48% sometimes measure their heart rates and 4% always do so ( p< 01). While the new guide should not replace the traditional chart, these results suggest that college students perceive the heart-rate guide as a useful tool despite the fact that only a small percentage of students regularly measure their heart rates when they exercise.


2012 ◽  
Vol 113 (10) ◽  
pp. 1530-1536 ◽  
Author(s):  
Robert Ojiambo ◽  
Kenn Konstabel ◽  
Toomas Veidebaum ◽  
John Reilly ◽  
Vera Verbestel ◽  
...  

One of the aims of Identification and Prevention of Dietary- and Lifestyle-Induced Health Effects in Children and Infants (IDEFICS) validation study is to validate field measures of physical activity (PA) and energy expenditure (EE) in young children. This study compared the validity of uniaxial accelerometry with heart-rate (HR) monitoring vs. triaxial accelerometry against doubly labeled water (DLW) criterion method for assessment of free-living EE in young children. Forty-nine European children (25 female, 24 male) aged 4–10 yr (mean age: 6.9 ± 1.5 yr) were assessed by uniaxial ActiTrainer with HR, uniaxial 3DNX, and triaxial 3DNX accelerometry. Total energy expenditure (TEE) was estimated using DLW over a 1-wk period. The longitudinal axis of both devices and triaxial 3DNX counts per minute (CPM) were significantly ( P < 0.05) associated with physical activity level (PAL; r = 0.51 ActiTrainer, r = 0.49 uniaxial-3DNX, and r = 0.42 triaxial Σ3DNX). Eight-six percent of the variance in TEE could be predicted by a model combining body mass (partial r2 = 71%; P < 0.05), CPM-ActiTrainer (partial r2 = 11%; P < 0.05), and difference between HR at moderate and sedentary activities (ModHR − SedHR) (partial r2 = 4%; P < 0.05). The SE of TEE estimate for ActiTrainer and 3DNX models ranged from 0.44 to 0.74 MJ/days or ∼7–11% of the average TEE. The SE of activity-induced energy expenditure (AEE) model estimates ranged from 0.38 to 0.57 MJ/day or 24–26% of the average AEE. It is concluded that the comparative validity of hip-mounted uniaxial and triaxial accelerometers for assessing PA and EE is similar.


1986 ◽  
Vol 55 (1) ◽  
pp. 1-6 ◽  
Author(s):  
Joan D. Webster ◽  
Gillian Welsh ◽  
J. S. Garrow

1. A heat-sink calorimeter, suitable for the measurement of energy expenditure in human subjects over periods up to 26 h, is described.2. The performance of the calorimeter is illustrated by a study of four normal subjects at rest or performing clerical work for a period of 7.5 h. Each condition was measured in duplicate in each subject. On the resting days the subjects were recumbent, and on the working days they were seated throughout the measurement period. Heart rate was monitored by infra-red telemetry and physical activity by an ultrasound movement detector. Urinary cortisol excretion was also measured as an indicator of stress.3. In each subject the mean heat loss on working days was higher than that on resting days: the increase ranged from 5.1 % to 16.7, with a mean value of 10.0% (P = 0.015). There was no significant difference between resting and working days in heart rate, physical activity or urinary cortisol excretion.4. The present study confirms that tiring clerical work has very little effect on 24 h energy expenditure.


Sign in / Sign up

Export Citation Format

Share Document