scholarly journals Loop-Mediated Isothermal Amplification for Detection ofStaphylococcus aureusin Dairy Cow Suffering from Mastitis

2012 ◽  
Vol 2012 ◽  
pp. 1-5 ◽  
Author(s):  
Zhang Tie ◽  
Wang Chunguang ◽  
Wei Xiaoyuan ◽  
Zhao Xinghua ◽  
Zhong Xiuhui

To develop a rapid detection method ofStaphylococcus aureususing loop-mediated isothermal amplification (LAMP), four specific primers were designed according to six distinct sequences of thenucgene. In addition, the specificity and sensitivity of LAMP were verified and compared with those of PCR. Results showed that the LAMP reaction was completed within 45 min at 62.5°C, and ladder bands were appeared in LAMP products analyzed by gel electrophoresis. After adding 1x SYBR Green l, the positive reaction tube showed green color and the negative reaction tube remained orange, indicating that the LAMP has high specificity. The minimal detectable concentration of LAMP was1×102 CFU/mL and that of PCR was1×104 CFU/mL, indicating that the LAMP was 100 times more sensitive than the PCR. The LAMP method for detection ofStaphylococcus aureushas many advantages, such as simple operation, high sensitivity, high specificity, and rapid analysis. Therefore, this method is more suitable for the rapid on-site detection ofStaphylococcus aureus.

2013 ◽  
Vol 16 (1) ◽  
pp. 131-133 ◽  
Author(s):  
Ł. Adaszek ◽  
M. Jankowska ◽  
M. Kalinowski ◽  
T. Banach ◽  
D. Wułupek ◽  
...  

Abstract The aim of this study was to use a rapid and easy DNA-based test, the loop-mediated isothermal amplification (LAMP), for diagnosis of Babesia canis canis infections in dogs. 10 DNA samples of 18S RNA-A and 10 DNA samples of 18S RNA-B of B. canis canis were used in the study. LAMP method could successfully detect DNA in all examined samples down to 0.1 pg dilution. Obtained results suggest that this method has high specificity and sensitivity and can be applied in analytical laboratories in diagnosis of canine babesiosis.


2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Mevaree Srisawat ◽  
Watanalai Panbangred

TheSalmonellaenterotoxin (stn) gene exhibits high homology amongS. entericaserovars andS. bongori. A set of 6 specific primers targeting thestngene were designed for detection ofSalmonellaspp. using the loop-mediated isothermal amplification (LAMP) method. The primers amplified target sequences in all 102 strains of 87 serovars ofSalmonellatested and no products were detected in 57 non-Salmonellastrains. The detection limit in pure cultures was 5 fg DNA/reaction when amplified at 65°C for 25 min. The LAMP assay could detectSalmonellain artificially contaminated food samples as low as 220 cells/g of food without a preenrichment step. However, the sensitivity was increased 100-fold (~2 cells/g) following 5 hr preenrichment at 35°C. The LAMP technique, with a preenrichment step for 5 and 16 hr, was shown to give 100% specificity with food samples compared to the reference culture method in which 67 out of 90 food samples gave positive results. Different food matrixes did not interfere with LAMP detection which employed a simple boiling method for DNA template preparation. The results indicate that the LAMP method, targeting thestngene, has great potential for detection ofSalmonellain food samples with both high specificity and high sensitivity.


2021 ◽  
Vol 8 ◽  
Author(s):  
Alfredo Garcia-Venzor ◽  
Bertha Rueda-Zarazua ◽  
Eduardo Marquez-Garcia ◽  
Vilma Maldonado ◽  
Angelica Moncada-Morales ◽  
...  

As to date, more than 49 million confirmed cases of Coronavirus Disease 19 (COVID-19) have been reported worldwide. Current diagnostic protocols use qRT-PCR for viral RNA detection, which is expensive and requires sophisticated equipment, trained personnel and previous RNA extraction. For this reason, we need a faster, direct and more versatile detection method for better epidemiological management of the COVID-19 outbreak. In this work, we propose a direct method without RNA extraction, based on the Loop-mediated isothermal amplification (LAMP) and Clustered Regularly Interspaced Short Palindromic Repeats-CRISPR associated protein (CRISPR-Cas12) technique that allows the fast detection of SARS-CoV-2 from patient samples with high sensitivity and specificity. We obtained a limit of detection of 16 copies/μL with high specificity and at an affordable cost. The diagnostic test readout can be done with a real-time PCR thermocycler or with the naked eye in a blue-light transilluminator. Our method has been evaluated on a small set of clinical samples with promising results.


2020 ◽  
Vol 48 (1) ◽  
Author(s):  
Hiroka Aonuma ◽  
Itoe Iizuka-Shiota ◽  
Tokio Hoshina ◽  
Shigeru Tajima ◽  
Fumihiro Kato ◽  
...  

Abstract Background Monitoring both invasion of Zika virus disease into free countries and circulation in endemic countries is essential to avoid a global pandemic. However, the difficulty lies in detecting Zika virus due to the large variety of mutations in its genomic sequence. To develop a rapid and simple method with high accuracy, reverse transcription-loop-mediated isothermal amplification (RT-LAMP) was adopted for the detection of Zika virus strains derived from several countries. Results Common primers for RT-LAMP were designed based on the genomic sequences of two standard Zika strains: African lineage, MR-766, and Asian lineage, PRVABC59. RT-LAMP reactions using a screened primer set, targeting the NS3 region, detected both Zika virus strains. The minimum detectable quantity was 3 × 10−2 ng of virus RNA. Measurable lag of reaction times among strains was observed. The RT-LAMP method amplified the target virus sequence from the urine and serum of a patient with a travel history in the Caribbean Islands and also provided a prediction about which lineage of Zika virus strain was present. Conclusions The RT-LAMP method using a well-optimized primer set demonstrated high specificity and sensitivity for the detection of Zika virus strains with a variety in genomic RNA sequences. In combination with the simplicity of LAMP reaction in isothermal conditions, the optimized primer set established in this study may facilitate rapid and accurate diagnosis of Zika fever patients with virus strain information.


2008 ◽  
Vol 57 (4) ◽  
pp. 439-443 ◽  
Author(s):  
Basu Dev Pandey ◽  
Ajay Poudel ◽  
Tomoko Yoda ◽  
Aki Tamaru ◽  
Naozumi Oda ◽  
...  

A number of nucleic acid amplification assays (NAAs) have been employed to detect tubercle bacilli in clinical specimens for tuberculosis (TB) diagnosis. Among these, loop-mediated isothermal amplification (LAMP) is an NAA possessing superior isothermal reaction characteristics. In the present study, a set of six specific primers targeting the Mycobacterium tuberculosis 16S rRNA gene with high sensitivity was selected and a LAMP system (MTB-LAMP) was developed. Using this system, a total of 200 sputum samples from Nepalese patients were investigated. The sensitivity of MTB-LAMP in culture-positive samples was 100 % (96/96), and the specificity in culture-negative samples was 94.2 % (98/104, 95 % confidence interval 90.5–97.9 %). The positive and negative predictive values of MTB-LAMP were 94.1 and 100 %, respectively. These results indicate that this MTB-LAMP method may prove to be a powerful tool for the early diagnosis of TB.


Author(s):  
Maryam ARFAATABAR ◽  
Narjes NOORI GOODARZI ◽  
Davoud AFSHAR ◽  
Hamed MEMARIANI ◽  
Ghasem AZIMI ◽  
...  

  Background: Mycoplasma pneumoniae is a common cause of community-acquired pneumonia (CAP) worldwide, especially among children and debilitated populations. The present study aimed to investigate a loop-mediated isothermal amplification (LAMP) technique for rapid detection of M. pneumoniae in clini-cal specimens collected from patients with pneumonia. Methods: Throat swabs were collected from 110 outpatients who suffered from pneumonia. Throat swab samples were obtained from patients referred to the hospital outpatient clinics of Tehran University hospitals, Iran in 2017. The presence of M. pneumoniae in the clinical specimens was evaluated by LAMP, PCR and culture methods. Sensitivity and specificity of the LAMP and PCR assays were also determined. Results: Out of 110 specimens, LAMP assay detected M. pneumoniae in 35 specimens. Detection limit of the LAMP assay was determined to be 33fg /μL or ~ 40 genome copies/reaction. Moreover, no cross-reaction with genomic DNA from other bacteria was observed. Only 25 specimens were positive by the culture method. The congruence between LAMP assay and culture method was ‘substantial’ (κ=0.77). Specificity and sensitivity of LAMP assay were 88.2%, 100% in compare with culture. However, the con-gruence between LAMP assay and PCR assay was ‘almost perfect’ (κ=0.86). Specificity and sensitivity of LAMP assay were 92.5%, 100% in compare with PCR. Conclusion: Overall, the LAMP assay is a rapid and cost-efficient laboratory test in comparison to other methods including PCR and culture. Therefore, the LAMP method can be applied in identification of M. pneumoniae isolates in respiratory specimens.


2021 ◽  
Author(s):  
Xi He ◽  
Derong Zhou ◽  
Yanwu Sun ◽  
Yuan Zhang ◽  
Xiaogang Zhang ◽  
...  

Abstract Background Toxoplasma gondii, an intracellular apicomplexan protozoan parasite, can infect all warm-blooded animals. Infected swine are considered one of the most important sources of T. gondii infection in humans. Rapidly and effectively diagnosing T. gondii infection in swine is essential. PCR-based diagnostic tests have been fully developed, and very sensitive and specific PCR is crucial for the diagnosis of swine toxoplasmosis. Methods To established a high specificity and sensitivity PCR detection method for swine toxoplasmosis, we used T. gondii GRA14 gene as target to design specific primers and established a PCR detection method for swine toxoplasmosis. A total of 5462 blood specimens collected from pigs in 5 provinces and autonomous regions in southern China during 2016–2017 were assessed by the newly established GRA14 gene PCR method. Result Altogether, we used T. gondii GRA14 gene as target to design specific primers and established a high specificity and sensitivity PCR detection method for swine toxoplasmosis; in particular, this PCR method could detect T. gondii tachyzoite DNA in the acute infection phase. The GRA14 gene PCR assay detected a minimum of 2.35 tachyzoites of T. gondii, and it could be used for T. gondii detection in blood, tissue, semen, urine and waste feed specimens. The overall T. gondii infection rate was 18.9% (1033/5462) by the newly established GRA14 gene PCR method. According to statistical analysis among different regions, the positive rates of swine toxoplasmosis in the Shaanxi, Fujian and Guangdong areas in China from 2016 to 2017 were the highest, at 31.7% (44/139), 21.9% (86/391) and 18.8% (874/4645), respectively (χ2 = 84.2, P < 0.0001). Specimens collected in 2017 had a higher positive rate (19.1% or 886/4639) than those collected in 2016 (16.1% or 155/963) (χ2 = 4.5, P < 0.05). Specimens collected in autumn (39.4% or 187/474), spring (22.8% or 670/2940) and winter (18.2% or 129/709) also had higher positive rates than those collected in summer (3.8% or 57/1479) (χ2 = 427.7, P < 0.0001). Conclusions These results indicate that the new PCR method based on the T. gondii GRA14 gene would be useful for the diagnosis of swine toxoplasmosis and that it would facilitate the diagnosis of toxoplasmosis in clinical laboratories.


2017 ◽  
Vol 11 (2) ◽  
pp. 20-27
Author(s):  
Arifa Akram

Disease diagnosis is important for implementation of proper therapeutic and prophylactic measures. Traditionally, disease diagnosis was depends upon isolation and identification of the causative organisms. This was followed by serology and after that molecular method. Molecular tests are valuable when early diagnosis is important. For this purpose, nucleic acid amplification (PCR, nucleic acid sequence-based amplification, self-sustained sequence replication, strand displacement amplification) is one of the most valuable tools not only for the diagnosis of infectious diseases but also used in advanced level research. The Loop-Mediated Isothermal Amplification (LAMP) is a unique nucleic acid amplification technique for diagnosis of various pathogens introduced at 2000 by Notomi and his colleagues which is simple, easy, rapid and cost effective when compared to PCR due to its high specificity, sensitivity, and rapidity. It uses a set of six primers and a DNA polymerase with stranddisplacement activity. Major advantage of LAMP method is its cost-effectiveness as it can be done simply by using waterbath or heating block. Bangladesh J Med Microbiol 2017; 11 (2): 20-27


Author(s):  
Yufei Chen ◽  
Hao Li ◽  
Liu Yang ◽  
Lei Wang ◽  
Ruyi Sun ◽  
...  

Botulinum neurotoxins are considered as one of the most potent toxins and are produced by Clostridium botulinum. It is crucial to have a rapid and sensitive method to detect the bacterium Clostridium botulinum in food. In this study, a rapid detection assay of C. botulinum in food using loop-mediated isothermal amplification (LAMP) technology was developed. The optimal primers were identified among three sets of primers designed specifically based on the partial ntnh gene encoding nontoxic-nonhaemagglutinin (NTNH) for rapid detection of the target DNA in plasmids. The optimal temperature and reaction time of the LAMP assay were determined to be 64 °C and 60 min, respectively. The chemical kit could be assembled based on these optimized reaction conditions for quick, initial high-throughput screening of C. botulinum in food samples. The established LAMP assay showed high specificity and sensitivity in detecting the target DNA with a limit of 0.0001 pg/ul (i.e., ten times more sensitive than that of the PCR method) and an accuracy rate of 100%. This study demonstrated a potentially rapid, cost-effective, and easy-operating method to detect C. botulinum in food and clinical samples based on LAMP technology.


Author(s):  
Johannes Köck ◽  
Christoph Gottschalk ◽  
Sebastian Ulrich ◽  
Karin Schwaiger ◽  
Manfred Gareis ◽  
...  

AbstractCytotoxic macrocyclic trichothecenes such as satratoxins are produced by chemotype S strains of Stachybotrys chartarum. Diseases such as stachybotryotoxicosis in animals and the sick building syndrome as a multifactorial disease complex in humans have been associated with this mold and its toxins. Less toxic non-chemotype S strains of S. chartarum are morphologically indistinguishable from chemotype S strains, which results in uncertainties in hazard characterization of isolates. To selectively identify macrocyclic trichothecene producing S. chartarum isolates, a set of sat14 gene-specific primers was designed and applied in a loop-mediated isothermal amplification (LAMP) assay using neutral red for visual signal detection. The assay was highly specific for S. chartarum strains of the macrocyclic trichothecene producing chemotype and showed no cross-reaction with non-macrocyclic trichothecene producing S. chartarum strains or 152 strains of 131 other fungal species. The assay’s detection limit was 0.635 pg/rxn (picogram per reaction) with a reaction time of 60 min. Its high specificity and sensitivity as well as the cost-saving properties make the new assay an interesting and powerful diagnostic tool for easy and rapid testing.