scholarly journals Simultaneous Estimation and Validation of Atorvastatin Calcium and Aspirin in Combined Capsule Dosage Form by RP HPLC Method

2012 ◽  
Vol 9 (3) ◽  
pp. 1449-1456
Author(s):  
B. V. Suma ◽  
K. Kannan ◽  
V. Madhavan ◽  
Chandini R. Nayar

A new simple, specific, precise and accurate revere phase liquid chromatography method has been developed for estimation of atorvastatin calcium (AST) and ASPIRIN (ASP) simultaneously in a combined capsule dosage forms. The chromatographic separation was achieved on a 5 – micron C 18 column (250x 4.6mm) using a mobile phase consisting of a mixture of Acetonitrile: Ammonium Acetate buffer 0.02M (68:32) pH 4.5. The flow rate was maintained at 0.8 ml/min. The detection of the constituents was done using UV detector at 245 nm for AST and ASP. The retention time of AST and ASP were found be 4.5915 ± 0.0031 min and 3.282 ±0.0024 min respectively. The developed method was validated for accuracy, linearity, precision, limit of detection (LOD) and limit of quantification (LOQ) and robustness as per the ICH guidelines.

2020 ◽  
Vol 11 (2) ◽  
pp. 2543-2548
Author(s):  
Gouru Santhosh Reddy ◽  
Animesh Bera ◽  
Madhurima Basak ◽  
Krishnaveni Nagappan ◽  
Ramalingam Peraman

The present study is aimed to develop a linear, precise, and accurate RP-HPLC (Reverse Phase High-Performance Liquid Chromatography) method for the determination of dapagliflozin in the formulation. The method was accomplished on a C18 column (250×4.6mm; 5µm), & Samples were eluted using acetonitrile: water (40:60%v/v) delivered at a flow rate of 1.0ml/min with a chromatographic run time of 10 min. The eluents were observed utilizing a UV detector with a wavelength set at 277nm. The method that was developed resulted in the retention of dapagliflozin at 7.029minutes. Dapagliflozin through current method has shown linearity (r2 > 0.999) over the concentration range of 1-16 µg/ml. The percentage recovery was observed to be within the limits of 98-102%, demonstrating the accuracy of the method. Limit of detection (LOD) and limit of quantification (LOQ) were qualified at 0.049µg/ml and 0.1485µg/ml, respectively. A Linear, precise, accurate, simple, and rapid RP-HPLC method has been developed and validated for the evaluation of dapagliflozin in bulk drug and tablet dosage forms (5mg &10mg) according to ICH Q2(R1) rules. Additionally, the proposed method could be of use in quality control tests of dapagliflozin in pharmaceutical industries.


Author(s):  
Poornima K. ◽  
Channabasavaraj Kp.

<p><strong>Objective: </strong>A new, rapid, selective, precise, accurate and economical, isocratic, reverse phase high-performance liquid chromatography method has been developed for simultaneous estimation of loperamide hydrochloride and tinidazole in bulk and in tablet formulations.</p><p><strong>Methods: </strong>The separation was achieved by using Lithosphere RP C-18, (250 x 4.6 mm, 5 µm) end capped column with a mobile phase containing sodium-1-octane sulfonate buffer: methanol: acetonitrile (40:30:30%v/v/v) pH adjusted to 4.0 (using dilute orthophosphoric acid). The flow rate was 1.0 ml/m and column effluent was monitored at 224 nm. The method was validated as per international conference on chemical harmonization (ICH) guidelines.</p><p><strong>Results</strong>:<strong> </strong>Tinidazole and loperamide hydrochloride were eluted at about 3.1 and 5.4 min respectively, indicating the shorter analysis time. The proposed method was found to be accurate, precise and reproducible. The linearity was established in the concentration range of 10-50 µg/ml. Limit of detection (LOD) and Limit of quantification (LOQ) was found to be 0.001 µg/ml and 0.003 µg/ml for loperamide hydrochloride and 0.01 µg/ml and 0.03 µg/ml for tinidazole.</p><p><strong>Conclusion: </strong>This method can be used for routine analysis of formulations containing any of the above drugs or combinations without any alteration in the chromatographic conditions.</p>


INDIAN DRUGS ◽  
2018 ◽  
Vol 55 (10) ◽  
pp. 56-62
Author(s):  
A Anerao ◽  
◽  
V. Dighe ◽  
A Gupta ◽  
C. Patil ◽  
...  

N-Methylethanolamine is the side chain of the drug diphenhydramine hydrochloride. A sensitive high performance liquid chromatography method with pre-column derivatization was developed and validated for the determination of N-methylethanolamine impurity in diphenhydramine hydrochloride active pharmaceutical ingredient. HPLC method on column Cosmosil MS-II, C-18, 250 mm X 4.6 mm, particle size 5 μm with UV detector was used. The proposed method is specific, linear, accurate, rugged and precise. The calibration curves showed good linearity over the concentration range of 0.03 mg/g to 1.5 mg/g and the correlation coefficient was 0.999. Method had very low limit of detection (LOD) and limit of quantification (LOQ) as 0.01 mg/g and 0.03 mg/g, respectively, of the analyte. Accuracy was observed within 94.4% to 96.2%.


INDIAN DRUGS ◽  
2017 ◽  
Vol 54 (08) ◽  
pp. 54-61
Author(s):  
B. Venkateswara Rao ◽  
◽  
S. Vidyadhara ◽  
V. Basaveswara Rao

The prime aim of the present investigation was to develop and validate a novel, precise, accurate, specific, rapid and economical stability- indicating isocratic reverse phase liquid chromatography method for the quantitative simultaneous estimation of valsartan and hydrochlorothiazide in bulk and marketed formulations. Estimation of drugs in this combination was achieved with a C18 column [Kromasil 100-5 C18 column, P134 250 × 4.6 mm] kept at ambient temperature, isocratic mode using mobile phase of composition acetonitrile and phosphate buffer (40:60 V/V, pH 4). The flow rate was 0.8 ml/min and the effluents were monitored at 235 nm, using variable wavelength UV detector. The retention time of valsartan and hydrochlorothiazide were 2.65 min and 3.97 min, respectively. Validation of the method was done according to the ICH guidelines for different analytical parameters. The method was found to be linear over a range of 50-250 μg/mL for valsartan and hydrochlorothiazide. The established method was as reproducible with a %RSD value of less than 2 and having robustness and accuracy within the specified limits. Assay of marketed formulation was determined and was 99.04% and 99.8% respectively. The stressed samples were analyzed. The proposed method was found to be specific and stability indicating as no interfering peaks of degradation compounds and excipients were noticed. The proposed method can be successfully employed in the estimation of commercial formulations.


Author(s):  
Gudipally. Mounika ◽  
K. Bhavya Sri ◽  
R. Swethasri ◽  
M. Sumakanth

To develop an accurate, precise, specific high performance liquid chromatography method for quantification of Canagliflozin in bulk and dosage forms. A C18 column (250mm X 4.6mm; 5μm phenomenex) was used with mobile phase containing Acetonitrile-0.1% sodium acetate buffer (pH-4.6), (20:80) in isocratic mode. The flow rate maintained was 1.0ml/min and the U.V detector was operated at 291nm. The retention time of Canagliflozin was 3.307min and showed a good linearity in concentration range of 2-14μg/ml with correlation coefficient of 0.999. The average percent recovery was found to be 99.98%. The developed method follows validation parameters such as system suitability, linearity, precision, accuracy, limit of detection and limit of quantification and robustness as per ICH guidelinesQ2(R1). The proposed method was found to provide faster retention time with sharp resolution with linearity at a lowest concentration as compared to previous methods and this method is validated as per International conference on harmonization guidelines and successfully applied for bulk and pharmaceutical dosage form.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Uma Sai Teja Yarra ◽  
Sowjanya Gummadi

Abstract Background Bempedoic acid and Ezetimibe acid are used in combination for treatment of hypercholesterolemia. The current work was undertaken to develop a simple and rapid stability-indicating RP-UPLC method for the simultaneous estimation of Bempedoic acid and Ezetimibe in tablets as no such method was available. The chromatographic separation was performed with Waters Acquity C18 [50 × 2.1 mm, 1.7 μ] column using methanol: acetonitrile: water [50: 30: 20, by volume] as mobile phase pumped at a flow rate 0.5 mL/min. The separated analytes were detected at 260 nm using UV detector. Results The separation of Bempedoic acid (BA) and Ezetimibe (EZ) was done at a retention time of 1.827 min. and 3.577 min. respectively. The validation and stability studies of the present method were carried out according to the ICH guidelines. The linearity of the proposed method was in the range of 30–130 μg/mL and 5–50 μg/mL for Bempedoic acid and Ezetimibe respectively. Limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.1216 μg/mL and 0.3685 μg/mL for Bempedoic acid and 0.1189 μg/mL and 0.3602 μg/mL for Ezetimibe respectively. The recovery of the method was found to be in the range of 99.89—100.31% for Bempedoic acid and 98.14—99.94% for Ezetimibe while the % RSD for both drugs in the precision and robustness study was less than 2.0. The drugs did not show any major degradants in the exposed conditions. Conclusion The developed method was found to be simple, sensitive, accurate, precise, robust, rapid and yet stability indicating. The method can be adopted for simultaneous estimation of Bempedoic acid and Ezetimibe in the pharmaceutical formulation.


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (09) ◽  
pp. 68-73
Author(s):  
K Vijaya Sri ◽  
M. Shiva Kumar ◽  
M. A. Madhuri ◽  
Suresha K. ◽  

In this study, a high-performance liquid chromatographic method (HPLC) was developed, validated and applied for the determination of raltegravir in biological sample like saliva. Liquid- liquid extraction was performed for isolation of the drug and elimination of saliva interferences. Samples of saliva was extracted with 50µL of ortho phosphoric acid and 3ml of methanol was added and spiked with raltegravir. The chromatographic separation was performed on Agilent Eclipse C18 (100 mm × 4.6 mm, 3.5µm) column, by using 80:20 v/v acetonitrile: water as a mobile phase under isocratic conditions at a flow rate of 1.0 mL/min for UV detection at 240 nm. Retention time of raltegravir was found to be 1.030 min. Linearity was found to be in the range of 25-1000 ng/mL with regression equation y = 13864x + 40495 and correlation coefficient 0.999. The low % RSD value indicates the method is accurate and precise. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.76 and 2.28 ng/mL, respectively. It can be concluded that this validated HPLC method is easy, precise, accurate, sensitive and selective for determination of raltegravir in saliva.


Author(s):  
Pankaj Yadav ◽  
Mohamad Taleuzzaman ◽  
Pradeep Kumar

A rugged robust RP-HPLC method has been developed and validated for the simultaneous quantification of Aspirin (ASP), Atorvastatin calcium (ATO) and Clopidogrel bisulphate (CLO) in a combined dosage form. Optimized mobile phase composition of 25 mM KH2PO4: Methanol (20:80% v/v) pH 3.0 (adjusted with 20% o-phosphoric acid) isocratic mode with flow rate of 1 ml  min-1, detection at 230 nm. Employed Princeton SPHER C18 (150 x 4.6 mm i.d. 5 µm) column for separation at ambient temperature with an isocratic flow. The linearity of each drug across the range of 0.5-32 µg/ml with correlation coefficient for ASP, ATO, and CLO in value of 0.979, 0.988 and 0.989 respectively. The retention time (min.) for ASP, ATO and CLO were found 1.85, 3.04 and 6.91 respectively. Limit of detection (LOD) of ASP, ATO and CLO - 0.04, 0.04, 0.08 (μg ml-1) respectively and Limit of Quantification (LOQ) of ASP, ATO and CLO- 0.14, 0.13, 0.28 (μg ml-1) in order. Performed analysis of marketed tablet formulation ASP (Ecosprin-75 mg), ATO (Aztor®40- 40 mg), CLO (Clopivas- 75 mg) found percentage recovery for ASP (99.93), ATO (100.00) and CLO (99.87). Performed stability studies found satisfactory results. Developed method has been validated, results of different parameter found in acceptable range. Chromatogram peaks are resolve, symmetric shape and without interference.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Ramya kuber B ◽  
Swetha Addanki

Abstract Background The present investigation was proposed to develop a simple, sensitive, rapid, accurate, precise stability-indicating RP-UPLC method for simultaneous estimation of sitagliptin and ertugliflozin. Chromatographic separation was performed with Waters Hibar C8 [100×2.1mm, 2μ] column and mobile phase acetonitrile: water (pH 3.5) [50:50%, v/v], pumped at a flow rate 0.2ml/min. The separated analytes were detected with a UV detector at a wavelength of 218nm. Results The separation of sitagliptin and ertugliflozin was done at a retention time of 0.859min and 1.570min, respectively. The present method was validated according to the ICH guidelines Q2 R1, and stability-indicating studies were carried out as per ICH guidelines Q1A R2. Intra-day and inter-day precision were found to be within acceptable limits. The linearity of the proposed method was in the concentration range of 25–125μg/ml and 3.75–22.5μg/ml for sitagliptin and ertugliflozin, respectively. Limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.5μg/ml and 1.53μg/ml for sitagliptin and 0.13μg/ml and 0.38μg/ml for ertugliflozin, respectively. The recovery of the method was found in between 99.7% and 100.7%. Conclusion The proposed method was able to distinguish the analytes from by-products. Hence, the method was successfully implied for stability-indicating studies and for routine examination of sitagliptin and ertugliflozin in pharmaceutical formulation.


2018 ◽  
Vol 8 (6) ◽  
pp. 68-73
Author(s):  
Ram Singh Bishnoi ◽  
Manish Kumar ◽  
Ajay Kumar Shukla ◽  
C.P. Jain

A simple, specific, accurate and precise high performance liquid chromatography method has developed for the estimation of rutin in Prosopis cineraria. The chromatographic separation was achieved by using C18 column, 150 x 4.6mm i.d., 5µ bonded phase octadecylsilane (Thermo Labs Hypersil). Mobile phase was composed of 80 parts of methanol & 20 parts of 0.05% formic acid. The pH of the mobile phase was 3.2.The retention time of rutin was found 5.7 min with 1 mL/min flow rate at ambient temperature. The estimation was performed on PDA detector at 281 nm. In this study, an excellent linearity was obtained with r2 0.999. Besides, the chromatographic peak was found sharp & symmetric. The proposed method was validated in terms of the analytical parameters such as accuracy, linearity, precision, robustness, limit of detection (LOD), limit of quantification (LOQ) were determined based on the International Conference on Harmonization (ICH) guidelines. The detector response was linear in the range of 2-10 µg/mL. The proposed method was successfully applied for the estimation of the constituents in crude extract of Prosopis cineraria. This study established a quantitative method for the determination of rutin from Prosopis cineraria.  Keywords: Prosopis cineraria, HPLC, Validation, Rutin.


Sign in / Sign up

Export Citation Format

Share Document