scholarly journals Validated Stability Indicating RP-HPLC Method for Simultaneous Estimation of Codeine Phosphate and Chlorpheniramine Maleate from Their Combined Liquid Dosage Form

2013 ◽  
Vol 2013 ◽  
pp. 1-7 ◽  
Author(s):  
Ramakrishna Kommana ◽  
Praveen Basappa

The present paper describes the development of quick stability indicating RP-HPLC method for the simultaneous estimation of codeine phosphate and chlorpheniramine maleate in the presence of its degradation products, generated from forced degradation studies. The developed method separates codeine phosphate and chlorpheniramine maleate in impurities/degradation products. Codeine phosphate and chlorpheniramine maleate and their combination drug product were exposed to acid, base, oxidation, dry heat, and photolytic stress conditions, and the stressed samples were analysed by proposed method. The proposed HPLC method utilizes the Shimadzu HPLC system on a Phenomenex C18 column (, 5 μ) using a mixture of 1% o-phosphoric acid in water : acetonitrile : methanol (78 : 10 : 12) mobile phase with pH adjusted to 3.0 in an isocratic elution mode at a flow rate of 1 mL/min, at 23°C with a load of 20 μL. The detection was carried out at 254 nm. The retention time of codeine phosphate and chlorpheniramine maleate was found to be around 3.47 min and 9.45 min, respectively. The method has been validated with respect to linearity, robustness, precision, accuracy, limit of detection (LOD), and limit of quantification (LOQ). The developed validated stability indicating HPLC method was found to be simple, accurate, and reproducible for the determination of instability of these drugs in bulk and commercial products.

2015 ◽  
Vol 2015 ◽  
pp. 1-11 ◽  
Author(s):  
V. Ashok Chakravarthy ◽  
B. B. V. Sailaja ◽  
Avvaru Praveen Kumar

The present work was the development of a simple, efficient, and reproducible stability-indicating reverse-phase high performance liquid chromatographic (RP-HPLC) method for simultaneous determination enrofloxacin (EFX) and its degradation products including ethylenediamine impurity, desfluoro impurity, ciprofloxacin impurity, chloro impurity, fluoroquinolonic acid impurity, and decarboxylated impurity in tablet dosage forms. The separation of EFX and its degradation products in tablets was carried out on Kromasil C-18(250×4.6 mm, 5 μm) column using 0.1% (v/v) TEA in 10 mM KH2PO4(pH 2.5) buffer and methanol by linear gradient program. Flow rate was 1.0 mL min−1with a column temperature of 35°C and detection wavelength was carried out at 278 nm and 254 nm. The forced degradation studies were performed on EFX tablets under acidic, basic, oxidation, thermal, humidity, and photolytic conditions. The degraded products were well resolved from the main active drug and also from known impurities within 65 minutes. The method was validated in terms of specificity, linearity, LOD, LOQ, accuracy, precision, and robustness as per ICH guidelines. The results obtained from the validation experiments prove that the developed method is a stability-indicating method and suitable for routine analysis.


2013 ◽  
Vol 2013 ◽  
pp. 1-9 ◽  
Author(s):  
Chinmoy Roy ◽  
Jitamanyu Chakrabarty

A simple, specific, precise, and accurate RP-HPLC method has been developed and validated for simultaneous estimation of Methylparaben (MP), Ketoconazole (KT), and Mometasone Furoate (MF) topical pharmaceutical dosage formulation. The separation was achieved by Waters X Terra C18 column using mobile phase consisting of buffer (triethyl amine in water, pH adjusted to 6.5 with glacial acetic acid)-acetonitrile (40 : 60, v/v) at a flow rate of 1.5 mL/min and detection at 250 nm. The method showed linearity with correlation coefficient <0.9999 over the range of 0.12–15.2 μg/mL, 0.67–149.4 μg/mL, and 0.42–7.6 μg/mL for MP, KT, and MF, respectively. The mean recoveries were found to be in the range of 99.9–101.1% for all the components. The method was validated as per the ICH guidelines for linearity, limit of detection, limit of quantification, accuracy, precision, robustness and solution stability. Stability indicating capability of the developed method was established by analyzing forced degradation of samples in which spectral purity of MP, KT, and MF along with separation of degradation products from analytes peak was achieved. The method can be successfully applied for routine analysis of quantitative determination of MP, KT, and MF in pharmaceutical dosage form.


2020 ◽  
Vol 11 (3) ◽  
pp. 3933-3941
Author(s):  
Supriya Reddy K ◽  
Chandan R. S. ◽  
Sai Charan A ◽  
Akshay N

A Specific, Linear and Precise reversed phase- HPLC was developed for the simultaneous estimation of Metformin HCl and Empagliflozin and the column used is Zorbax SB Phenyl with length, Internal diameter and Particle size of 250mm, 4.6 mm and 5µm respectively. The Mobile phase is Phosphate buffer: ACN: Methanol in ratio 45:25:30. 1.0 ml/min was the used flow rate and the wavelength was adjusted to 220nm for detection. The retention time for Empagliflozin was found to be 5.5min and for Metformin was 9.3min. Both the APIs exhibited good linearity revealing correlation coefficient(R) of 0.9999. The percentage recoveries for Metformin and Empagliflozin was found to be 100.0 – 100.9% and 100.3 – 102.4% respectively which was found to be within the limit. Forced degradation studies were performed and the developed method has suitable specificity as no interference is observed with impurity spiked sample and placebo of Drug Product. The proposed drug products were subjected to various types of stress conditions according to ICH Q1 guidelines like acidic, alkaline, neutral, peroxide, and Thermal conditions. The degradation products were well resolved from the main peaks , thus indicating the stability- indicating nature of the method. The method was validated with respect to system suitability, linearity, accuracy, precision and robustness according to ICH guidelines and the proposed RP-HPLC Method was accurate, precise and linear for the simultaneous determination of Metformin and Empagliflozin in bulk and pharmaceutical formulations.


Author(s):  
Murlidhar V. Zope ◽  
Rahul M. Patel ◽  
Ashwinikumari Patel ◽  
Samir G. Patel

Objective: The objective of the current study was to develop and validate a simple, robust, precise and accurate RP-HPLC (reverse phase-high performance liquid chromatography) method for the quantitative determination of potential degradation products of Difluprednate (DIFL) in the ophthalmic emulsion.Methods: Chromatographic separation was achieved on the YMC pack ODS-AQ (150× 4.6) mm, 3μm column with a mobile phase containing a gradient mixture of mobile phase A (0.02M Ammonium formate buffer pH 4.5 adjusted with formic acid) and Acetonitrile as mobile phase B, at flow rate of 1.5 ml/min and with UV detection at 240 nm.Results: The peak retention time of DIFL was found at about 17.2 min, the RRT of degradation product-1 (DP-1), degradation product-2 (DP-2), and degradation product-3 (DP-3), were found to be about 0.49, 0.65 and 0.79 respectively (calculated with respect to Difluprednate). Stress testing was performed in accordance with an ICH (international council for harmonisation) guideline Q1A (R2) [1]. The method was validated as per ICH guideline Q2 (R1)[2]. The calibration curve was found to be linear in the concentration range of 0.1 to 0.75 µg/ml for Difluprednate, DP-1, DP-2 and DP-3. The LOD (Limit of detection) was found to be 0.1µg/ml and LOQ (Limit of quantification) of 0.15µg/ml for Difluprednate, DP-1, DP-2 and DP-3 respectively. The recovery from LOQ to 150% was within 90-110%. The forced degradation data confirms the stability indicating the nature of the method.Conclusion: A simple, robust, precise and accurate RP-HPLC method for the quantitative determination of potential degradation products of Difluprednate in the ophthalmic emulsion was developed and validated. 


Author(s):  
Vaishali Mistry ◽  
Rohan Mishra

Objective: This study describes the stability-indicating reverse-phase high-performance liquid chromatography (RP-HPLC) method for simultaneous estimation of betahistine dihydrochloride and domperidone in pharmaceutical dosage forms.Methods: The proposed RP-HPLC method was developed using Shimadzu Prominence-i LC-2030 HPLC system equipped with UV detector and chromatographic operation was carried on Shim-pack C18 (250 mm×4.6 mm, 5 μ) column at a flow rate of 1 ml/min and the run time was 10 min. The mobile phase consisted of methanol and water in the ratio of 80:20% v/v and eluents were scanned using a UV detector at 244 nm.Results: The retention time of betahistine dihydrochloride and domperidone was found to be 2.3 and 3.6 min, respectively. A linearity response was observed in the concentration range of 9.6 μg/ml–22.4 μg/ml for betahistine dihydrochloride and 6–14 μg/ml for domperidone, respectively. Limit of detection and limit of quantification for betahistine dihydrochloride were 0.52 μg/ml and 1.58 μg/ml and for domperidone are 0.64 μg/ml and 1.94 μg/ml, respectively.Conclusion: The stability-indicating method was developed by subjecting drugs to stress conditions such as acid and base hydrolysis, oxidation, photo and thermal degradation, and degraded products formed were resolved successfully from samples.


Author(s):  
Birva A. Athavia ◽  
Zarna R. Dedania ◽  
Ronak R. Dedania ◽  
S. M. Vijayendra Swamy ◽  
Chetana B. Prajapati

Objective: The aim and objective of this study was to develop and validate Stability Indicating HPLC method for determination of Vilazodone Hydrochloride.Methods: The method was carried out on a Phenomenex, C18 (250x4.6 mm, 5 µm) Column using a mixture of Acetonitrile: Water (50:50v/v), pH adjusted to 3.3 with Glacial Acetic Acid for separation. The flow rate was adjusted at 1 ml/min and Detection was carried out at 240 nm.Results: The retention time of vilazodone hydrochloride was found to be 2.3 min. The calibration curve was found to be linear in the range 25-75µg/ml with a correlation coefficient (R2=0.996). The limit of detection and limit of quantitation were found to be 4.78µg/ml and 14.48µg/ml respectively. The % recovery of vilazodone hydrochloride was found to be in the range of 98.21±0.08 % to 99.07±0.64%. The proposed method was successfully applied for the estimation of vilazodone hydrochloride in marketed tablet formulation.Vilazodone Hydrochloride was subjected to forced degradation under Acidic, Alkaline, Oxidation, Dry Heat and Photolytic degradation conditions. Vilazodone hydrochloride showed 3.12% degradation under acidic condition, 4.78% under alkaline condition, 7.8% under oxidation condition, 3.53% under dry heat condition and 4.9% under photolytic condition.Acid degradation impurity was identified and characterised by LC-MS/MS was found to be 1-(4-Penten-1-yl) piperazine having molecular weight 154.253 (m/z 155.08) and Molecular Formula C9H18N2.Conclusion: A simple, precise, rapid and accurate Stability Indicating HPLC method has been developed and validated for the determination of Vilazodone Hydrochloride in presence of its degradation products as per the ICH Guidelines. 


2020 ◽  
Vol 11 (1) ◽  
pp. 781-789
Author(s):  
Sriram Valavala ◽  
Nareshvarma Seelam ◽  
Subbaiah Tondepu ◽  
Suresh Kandagatla

The present study aims to develop a simple, accurate and specific stability-indicating RP-HPLC technique for the analysis of metoclopramide in the presence of its stress degradation products and characterization of degradation compounds by LC-MS/MS analysis. As per ICH Q1A-R2 guidelines, the drug was exposed to acid hydrolytic stress condition. Three degradation products were formed for MCP in acid hydrolysis. The liquid chromatography was processed on a Luna C18-(2) 100A,250×4.6mm 5micron column using an isocratic mobile phase consisting of 0.1% formic acid in water-acetonitrile (20:80, v/v) by adjusting the mobile phase at 1 ml/min flow rate with wavelength detection at 273 nm. The developed procedure was applied to LC-MS/MS (liquid chromatography-tandem mass spectrometry) for the characterization of all the degradant components. Total new three degradation compounds were recognized and identified by LC-MS/MS. The developed RP-HPLC technique was validated as per the ICH Q2-R1 guidelines. Limit of detection and limit of quantification values of MCP were evaluated from the linearity graph and were found to be 5.23 µg/ml and 17.44 µg/ml. Accuracy study was established at 80.0, 100.0 and 120.0 µg/ml concentration levels and the findings were found in the range of 98.4% - 101.8%. The linearity of the technique was assessed over the drug concentration range of 50.0 µg/ml to 250.0 µg/ml and the regression equation, slope and correlation coefficient values were found to be y = 10618x + 1623.2, 10618 and 0.9996 respectively. The developed technique was uninterruptedly applied for the quantification of metoclopramide inactive pharmaceuticals.


Author(s):  
Ramreddy Godela ◽  
Sowjanya G

A trouble-free, simple, specific and highly sensitive stability indicating phase HPLC method was developed for concurrent assessment of Daclatasvir and Sofosbuvir in pure and in their combined tablet formulation. An effectual separation was accomplished by using XDB Phenyl (250 x 4.6mm, 5µ,100 A0) column, mobile phase composition of Acetonitrile: buffer(0.1%v/v Trifluoroaceticacid in water) (50:50 v/v) and isocratic elution at a flow rate of 1ml/min and detection wavelength of 275nm. The extreme stress conditions like hydrolysis with acid and base, peroxide oxidation, thermal decomposition were used as per ICH specifications to assess the stability of the analytes in bulk and dosage forms. The retention times of Daclatasvir and Sofosbuvir were found at 2.8 and 3.7min respectively. The proposed method has linear response in the concentration ranges from 12 to 36µg/ml and 80 to 240 µg/ml for Daclatasvir and Sofosbuvir respectively. The detection and quantification limits calculated as 2.5μg/ml and 7.8μg/ml for DCL, 5.2μg/ml and 15.8μg/ml SOF respectively. All the method validation parameters were met the acceptance limits of Q2 specifications of ICH procedures. The degradation products produced by forced degradation studies were have good resolution from Daclatasir and Sofosbuvir peaks, which represents the methods stability. The proposed RP-HPLC method was highly sensitive, precise, stability indicating and economical. That’s why the method has the capacity to employ in the pharmaceutical manufacturing of Daclatasvir and Sofosbuvir and routine analysis in quality control department.


2016 ◽  
Vol 9 (1) ◽  
pp. 54
Author(s):  
Megha Sharma ◽  
Neeraj Mahindroo

Objective: The objective of the present study was to develop and validate a novel stability indicating reverse phase-high performance liquid chromatography (RP-HPLC) method for determination of β-acetyldigoxin, an active pharmaceutical ingredient (API).Methods: The chromatographic separation was carried out on Agilent Technologies 1200 series HPLC system equipped with photo diode array detector and C-18 (4.6x250 mm, 5 µ) column. The mobile phase consisted of water: acetonitrile (65:35 v/v), delivered at a flow rate of 1.5 ml/min and eluents were monitored at 225 nm.Results: The retention time of β-acetyldigoxin was 9.2 min. The method was found to be linear (R2= 0.9995) in the range of 31.25-500 µg/ml. The accuracy studies showed the mean percent recovery of 101.02%. LOD and LOQ were observed to be 0.289 µg/ml and 0.965 µg/ml, respectively. The method was found to be robust and system suitability testing was also performed. Forced degradation analysis was carried out under acidic, alkaline, oxidative and photolytic stress conditions. Significant degradation was observed under tested conditions, except for oxidative condition. The method was able to separate all the degradation products within runtime of 20 min and was able to determine β-acetyldigoxin unequivocally in presence of degradation products.Conclusion: The novel, economic, rapid and simple method for analysis of β-acetyldigoxin is reported. The developed method is suitable for routine quality control and its determination as API, and in pharmaceutical formulations and stability study samples.


Sign in / Sign up

Export Citation Format

Share Document