scholarly journals Development and Validation of an RP-HPLC Method for Estimation of Chlorpheniramine Maleate, Ibuprofen, and Phenylephrine Hydrochloride in Combined Pharmaceutical Dosage Form

2013 ◽  
Vol 2013 ◽  
pp. 1-6 ◽  
Author(s):  
Pinak M. Sanchaniya ◽  
Falgun A. Mehta ◽  
Nirav B. Uchadadiya

The objective of this paper is to develope a simple, precise, accurate, and reproducible reversed phase high performance liquid chromatographic method for the quantitative determination of chlorpheniramine maleate, ibuprofen, and phenylephrine hydrochloride in combined pharmaceutical dosage form. Analysis was carried out using acetonitrile : mathanol : phoshphate buffer (50 : 20 : 30, v/v/v, pH 5.6) mobile phase at 1.0 mL/min flow rate and Sunfire C 18 column (5 μm × 250 mm × 4.6 mm) as stationary phase with detection wavelength of 220 nm. The retention times of chlorpheniramine maleate (CPM), ibuprofen (IBU), and phenylephrine hydrochloride (PHE) were 4.2 min, 13.6 min, and 2.7 min, respectively. The proposed method was validated with respect to linearity, accuracy, precision, specificity, and robustness. The linearity for chlorpheniramine maleate, ibuprofen, and phenylephrine hydrochloride was in the range of 0.5–2.5 μg/mL, 25–125 μg/mL, and 1.25–6.25 μg/mL, respectively. The % recoveries of all the three drugs were found to be 99.44–101.61%, 99.39–101.79%, and 98.66–101.83%. LOD were found to be 32, 120, and 68 ng/mL for CPM, IBU, and PHE, respectively. The method was successfully applied to the estimation of chlorpheniramine maleate, ibuprofen, and phenylephrine hydrochloride in combined pharmaceutical dosage form.

2017 ◽  
Vol 4 (1) ◽  
pp. 5-10 ◽  
Author(s):  
Ramesh Jayaprakash ◽  
Senthil Kumar Natesan

A simple, economic, accurate, sensitive, specific and precise stability indicating reverse phase high performance liquid chromatographic [RP-HPLC] method for the determination of Regorafenib in pure and tablet dosage from was developed and validated. The chromatographic separation was carried out using Phenomenex Luna-C18 column (4.5x250 mm; 5 µm particle size) as a stationary phase and methanol: acetonitrile: water (55:25:20 v/v/v) as a mobile phase. The flow rate of 1 mL/min was used with PDA detection at 275 nm. The retention time of Regorafenib was 2.480 min. RP-HPLC method was developed with linearity range of 40-240 µg/mL of Regorafenib. The correlation coefficient [r2] was found to be 0.9999. The assay results obtained was in good agreement with the corresponding labeled amount by developed method within range of 98.83 ± 0.6937. Accuracy of the method was confirmed by recovery studies and the recoveries were found to be between 99.61 % and 100.22 %, the corresponding %RSD was found to be 0.2029. Precision, LOD, LOQ, specificity, robustness and ruggedness were performed as per ICH Q2(R1) guidelines and were within the acceptance criteria. This method can be conveniently used to detect the possible degradation product in the dosage form of Regorafenib during stability studies (acidic, alkaline, oxidative, thermal and photolytic). The method proved to be effective on the analysis of stressed marketed tablet formulation.


2012 ◽  
Vol 10 (2) ◽  
pp. 67-70
Author(s):  
Abdullah Al Masud ◽  
Mohammad Saydur Rahman ◽  
Towfika Islam ◽  
Saki Sultana ◽  
Moynul Hasan ◽  
...  

A simple, reproducible and efficient reversed phase high performance liquid chromatographic (RPHPLC) method has been developed for the estimation of a recently approved anti allergic drug, amlexanox in oral paste dosage form. The separations were carried out on a Zorbax Eclipse XBD, C18 column (150 x 4.6 mm; 5?m) at a flow rate of 1.50 ml/min. by using mobile phase comprising of mixed buffer (pH adjusted to 6.50) and methanol (50:50 v/v). The injection volume was 10 ?l and the peaks were detected at 244 nm. The linear dynamic range found to be in the concentration range of 15-35 ?g/ml and coefficient of correlation was found to be 0.999. The %RSD value was below 2.0 for intra-day and inter-day precision which indicated that the method was highly precise. The LOD (Limit of detection) and LOQ (Limit of quantitation) were found to be 3.8 ng/ml and 12.5 ng/ml, respectively which revealed that the method was highly sensitive. The percentage recovery of amlexanox ranged from 99.31 to 99.75%, indicating the accuracy of the method and absence of interference from the excipients present in the formulation. The proposed method was simple, fast, accurate and reproducible and hence can be applied for routine quality control operations of amlexanox in oral paste dosage form. Key words: Amlexanox, Anti allergic, RP-HPLC, LOD, LOQ. DOI: http://dx.doi.org/10.3329/dujps.v10i2.11782 Dhaka Univ. J. Pharm. Sci. 10(2): 67-70, 2011 (December)


2013 ◽  
Vol 2013 ◽  
pp. 1-7
Author(s):  
U. K. Chhalotiya ◽  
K. K. Bhatt ◽  
D. A. Shah ◽  
S. L. Baldania ◽  
S. B. Patel

A rapid, specific, and sensitive reverse phase high performance liquid chromatographic method has been developed and validated for analysis of tolperisone in both bulk and pharmaceutical dosage form. The HPLC method was performed with a reversed phase C18 SunFire column (250 mm × 4.6 mm i.d., 5 mm particle size), detection at 261 nm and a mixture of methanol, water and pH 7.5 adjusted by use of 1% solution of triethylamine (60 : 40) as mobile phase. The flow rate was 1.0 mL min−1 and effluents were monitored at 261 nm. The retention time of tolperisone was 4.8 min. Tolperisone was subjected to acid and alkali hydrolysis, chemical oxidation, wet hydrolysis, dry heat degradation, and sunlight degradation. The degraded product peaks were well resolved from the pure drug peak with significant difference in their retention time values. Stressed samples were assayed using developed LC method. The proposed method was validated with respect to linearity, accuracy, precision, and robustness. The method was successfully applied to the estimation of tolperisone in tablet dosage forms.


2008 ◽  
Vol 91 (5) ◽  
pp. 1045-1050 ◽  
Author(s):  
Gopal Garg ◽  
Shailendra Saraf ◽  
Swarnlata Saraf

Abstract Simple, accurate, economical, and reproducible UV spectrophotometric and column high-performance liquid chromatographic (HPLC) methods were developed for simultaneous estimation of a 2-component drug mixture of metoprolol tartrate and hydrochlorothiazide in combined tablet dosage form. The first method used the simultaneous equation method with 7 mixed standards and the absorption maxima at 223 and 271 nm, respectively, for metoprolol tartrate and hydrochlorothiazide in methanol. Linearity was observed in the concentration ranges of 424 and 216 g/mL for metoprolol tartrate and hydrochlorothiazide, respectively. The developed HPLC method used a reversed-phase C18 column and methanolwater (95 + 5) mobile phase at an ambient temperature of 27 2C and UV detection at 225 nm; the run time was 10 min, and quantification was based on peak area. The injection repeatability and intraday and interday repeatability were calculated. Paracetamol was used as an internal standard for the HPLC method, and linearity was observed in the concentration range of 550 g/mL for metoprolol and 220 g/mL for hydrochlorothiazide. The proposed methods were successfully applied for the determination of metoprolol tartrate and hydrochlorothiazide in bulk powder and dosage form. The results obtained were analyzed statistically, and there was no significant difference between the 2 methods. The validation was performed according to International Conference on Harmonization guidelines.


Author(s):  
DYADE GK ◽  
SAWANT RL

Objective: A reverse-phase high-performance liquid chromatographic (RP-HPLC) method was developed and validated for the simultaneous estimation of amlodipine besylate (AD) and valsartan (VAL) in pharmaceutical dosage form, and rosuvastatin (RV) and VAL from the bulk mixture. Method: Chromatographic separation was performed on RP-C18 column. The optimized unique mobile phase (acetonitrile:water and pH adjusted to 4.8 with acetic acid) was pumped at a flow rate of 0.8 ml/min in the ratio of 75:25% v/v, and the eluents were monitored at 245 nm. Results: The assay was performed with tablet and percentage of assay was found to 101.39 for AD and 100.05 for VAL, respectively, and with bulk mixture, percentage of assay was found to 99.58 for RV and 100.32 for VAL, respectively. Linearity was obtained in the concentration range of 1–12 μg/ml for AD, 5–50 μg/mL for VAL, and 2–20 μg/ml for RV. The method was statistically validated and RSD was found to be <2%, indicating high degree of accuracy and precision of the proposed RP-HPLC method. Conclusions: The method suggests usefulness of unique mobile phase during the estimation of two or more multicomponent dosage forms. Due to its simplicity, rapidness, high precision, and accuracy, the proposed RP-HPLC method can be applied for simultaneous determination of AD and VAL in pharmaceutical dosage form, and RV and VAL in bulk mixture.


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (02) ◽  
pp. 39-46
Author(s):  
Babu D. China ◽  
◽  
C. Madhusudhana Chetty ◽  
Sk. Mastanamma

A simple, accurate, precise and robust reversed phase high performance liquid chromatographic (RP-HPLC) method was developed for the estimation of Ertugliflozin (ETZ) and metformin (MFN) in bulk and in tablet dosage form. The method was carried out by used Waters (5μm, C18 250 x 4.6 mm) column with mobile phase consists of 0.75 mM sodium dihydrogen orthophosphate buffer pH adjusted to 8.5, with NaOH, and acetonitrile in the ratio of 60:40 v/v, a flow rate of 1.5 mL/min and photodiode detection at 263 nm. The method was validated as per ICH guidelines with different parameters, the mean retention times of ertugliflozin and metformin were found to be 3.5& 2.0 min, respectively. The correlation coefficient values of calibration curves were found to be 0.999 for both ETZ and MFN, respectively. The LOD and LOQ for ertugliflozin and metformin were found to be 0.02-0.06 μg/mL and 17.5-58.3 μg/mL respectively.


2019 ◽  
Vol 31 (5) ◽  
pp. 1002-1008
Author(s):  
Somana Siva Prasad ◽  
G.V. Krishna Mohan ◽  
A. Naga Babu

A novel reversed-phase high performance liquid chromatographic (HPLC) technique for the determination of everolimus (Isomer-B) and its impurities in the tablet dosage form has been optimized using analytical quality by design (QbD) approach. All the compounds are monitored with the photodiode array (PDA) detector at 280 nm and the parameters namely; precision, accuracy, specificity, stability, linearity, limit of quantitation (LOQ) and limit of detection (LOD) are evaluated. The quantitation limits of IMP-A, IMP-B, IMP-C, IMP-D, IMP-E, Sirolimus and TGR are found to be 0.08, 0.08, 0.10, 0.10, 0.10, 0.08 and 0.08, respectively. Recovery studies from 0.9 mg/L to 9.0 mg/L are performed for all impurities and the values were obtained between 85-110 %. Injection volume and test concentrations have been optimized to achieve LOQ values under the reporting threshold. The whole technique is developed and validated as per International Council for Harmonization (ICH) guidelines. The proposed method is robust, sensitive, rapid and successful and helpful in the regions where regulatory agencies recommend HPLC analytical method.


2020 ◽  
Vol 10 (5) ◽  
pp. 143-148
Author(s):  
T. Hanuman ◽  
T. Sivakkumar ◽  
S. Sridhar

A simple, specific and accurate reverse phase high performance liquid chromatographic method was developed for the simultaneous determination Sofosbuvir and Velpatasvirin pharmaceutical dosage form. The column used was Kromosil C18(150mm x 4.6 mm, 5mm)in isocratic mode, with mobile phase containing phosphate buffer andacetonitrile(70:30v/v). The buffer is prepared by adding 1.41gm of sodium dihyrogen ortho phosphate in a 1000ml of volumetric flask add about 900ml of milli-Q water added and degas to sonicate and finally make up the volume with water then pH adjusted to 3.5 with dil. orthophosphoric acid solution. The flow rate was 1.0ml/ min and effluents were monitored at 260 nm. The retention times of Sofosbuvir and Velpatasvirwere found to be 2.404min and 2.986 min, respectively. The linearity for Sofosbuvir and Velpatasvirwere in the range of 40-240µg/ml and 10-60 µg/ml respectively. The recoveries of Sofosbuvir and Velpatasvirwere found to be 99.64% and 99.25%, respectively. The proposed method was validated and successfully applied to the estimation of Sofosbuvir and Velpatasvirin combined tablet dosage forms. Keywords: Sofosbuvir, Velpatasvir, Validation, Buffer and ICH Guidelines.


2020 ◽  
Vol 9 (2) ◽  
pp. 1000-1003

For the determination of pitavastatin calcium nanoemulsion liquid dosage form a simple, sensitive, reliable and rapid reversed-phase high-performance liquid chromatographic (RP-HPLC) method has been developed and validated. 5 μ particle size column in isocratic mode at 25ºC temperature. The sample was injected through an injector valve with a 10 μl, sample loop. Phosphate buffer (pH 6.4): Methanol (50:50 v/v) was used as a mobile phase with a flow rate of 1 ml per min at 286 nm wavelength. A calibration graph was plotted range between 25-200 μg/ml with the correlation coefficient of 0.999 which showed linearity. Validation studies revealed the method is specific, rapid, reliable, and reproducible. The validity of the method, degradation studies were carried out using the same optimum conditions. Therefore the proposed method is reliable, rapid, precise and selective and may be used for the quantitative analysis of nanoemulsion liquid dosage form of pitavastatin calcium.