scholarly journals Development and Validation of a Stability Indicating RP-HPLC Method for the Determination of Two Sun Protection Factors (Koptrizon and Tinosorb S) in Topical Pharmaceutical Formulations Using Experimental Designs

2013 ◽  
Vol 2013 ◽  
pp. 1-12 ◽  
Author(s):  
Chinmoy Roy ◽  
Jitamanyu Chakrabarty

A novel, simple, validated stability indicating HPLC method was developed for determination of Koptrizon and Tinosorb S. Stability indicating power of the method was established by forced degradation study. The chromatographic separation was achieved with Waters X Bridge column, by using mobile phase consisting of a mixture of acetonitrile : tetrahydrofuran : water (38 : 38 : 24, v/v/v). The method fulfilled validation criteria and was shown to be sensitive, with limits of detection (LOD) and quantitation (LOQ) of 0.024 and 0.08 μg  for Koptrizon and 0.048 and 0.16 μg  for Tinosorb S, respectively. The developed method is validated for parameters like precision, accuracy, linearity, solution stability, specificity, and ruggedness as per ICH norms. Design expert with ANOVA software with linear model was applied and a 23 full factorial design was employed to estimate the model coefficients and also to check the robustness of the method. Results of the two-level full factorial design, 23 with 10 runs including two-centre-point analysis based on the variance analysis (ANOVA), demonstrated that all three factors, as well as the interactions between retention time of Koptrizon, Tinosorb S, and USP plate count for Koptrizon, are statistically significant.

2010 ◽  
Vol 7 (1) ◽  
pp. 246-252 ◽  
Author(s):  
S. K. Patro ◽  
S. K. Kanungo ◽  
V. J. Patro ◽  
N. S. K. Choudhury

A simple, rapid and accurate and stability indicating RP-HPLC method was developed for the determination of valsartan in pure and tablet forms. The method showed a linear response for concentrations in the range of 50-175 µg/mL using 0.01 M NH4H2PO4(pH 3.5) buffer: methanol [50:50] as the mobile phase with detection at 210 nm and a flow rate of 1 mL/min and retention time 11.041 min. The method was statistically validated for accuracy, precision, linearity, ruggedness, robustness, forced degradation, solution stability and selectivity. Quantitative and recovery studies of the dosage form were also carried out and analyzed; the % RSD from recovery studies was found to be less than 1. Due to simplicity, rapidity and accuracy of the method, we believe that the method will be useful for routine quality control analysis.


2021 ◽  
Vol 104 (4) ◽  
pp. 57-68
Author(s):  
V.G. Kamani ◽  
◽  
M. Sujatha ◽  
G.B. Daddala ◽  
◽  
...  

This study reports for the first time about a stability indicating RP-HPLC method for analysis of darolutamide and its impurities 1, 2, and 3 in bulk and formulations. The separation was achieved on Phenomenex column with Luna C18 (250 mm × 4.6 mm, 5 μm) as stationary phase, and 50 mM ammonium acetate: methanol solution 15:80 (v/v) at pH 5.2 as mobile phase at 1.0 mL/min flow rate. UV detection was carried at wavelength of 239 nm. In these conditions the retention time of darolutamide and its impurities 1, 2, and 3 was 7.05, 8.90, 4.63 and 5.95 min, respectively. The method was validated for system suitability, range of analysis, precision, specificity, stability, and robustness. Forced degradation study was done through exposure of the analyte to five different stress conditions and the % degradation was small in all degradation condition. The proposed method can separate and estimate the drug and its impurities in pharmaceutical formulations. Hence, the developed method was suitable for the quantification of darolutamide and can separate and analyse impurities 1, 2, and 3


Author(s):  
Sreenivasulu S ◽  
Rameswara Rao M ◽  
Chandra Sekhar KB

A simple, authentic and stability indicating high performance liquid chromatographic method for determination of Canagliflozin in bulk and pharmaceutical formulations was developed and validated as per ICH Q2 R1 Guidelines, A C18 Column (250mm length×4.6 mm diameter x 5 μm particle size) with a mobile phase consisting of Acetonitrile: 1-octanesulphonic acid in a ratio of 70:30 v/v was employed for the chromatographic study. A flow rate of 1.0 mL/min with an injection volume of 20 μL was selected for this study and the proposed method was validated with different parameters such as Linearity, Precision, Accuracy, Robustness, Ruggedness, Limit of Detection (LOD) and Limit of Quantification (LOQ). Canagliflozin was eluted at 3.4 ± 0.5 min and detected at 245 nm. The method is linear over the concentration range of 10-100 μg/mL with correlation co-efficient r = 0.9997. The plate count and tailing factor was found 5398 and 1.05 respectively. The LOD and LOQ were found to be 0.0170 μg/mL and 0.1705 μg/mL respectively. The percentage recovery was achieved in the range of 98-102%, which was within the acceptance criteria. Developed method was employed to determine the amount of Canagliflozinpresent in dosage form (Sulisent). The stabilityof the method was demonstrated by forced degradation studies of drug in which it was degraded under conditions of hydrolysis (acidic and alkaline), oxidation, photolytic and thermal stress as per ICH guideline Q1A (R2).


Author(s):  
Birva A. Athavia ◽  
Zarna R. Dedania ◽  
Ronak R. Dedania ◽  
S. M. Vijayendra Swamy ◽  
Chetana B. Prajapati

Objective: The aim and objective of this study was to develop and validate Stability Indicating HPLC method for determination of Vilazodone Hydrochloride.Methods: The method was carried out on a Phenomenex, C18 (250x4.6 mm, 5 µm) Column using a mixture of Acetonitrile: Water (50:50v/v), pH adjusted to 3.3 with Glacial Acetic Acid for separation. The flow rate was adjusted at 1 ml/min and Detection was carried out at 240 nm.Results: The retention time of vilazodone hydrochloride was found to be 2.3 min. The calibration curve was found to be linear in the range 25-75µg/ml with a correlation coefficient (R2=0.996). The limit of detection and limit of quantitation were found to be 4.78µg/ml and 14.48µg/ml respectively. The % recovery of vilazodone hydrochloride was found to be in the range of 98.21±0.08 % to 99.07±0.64%. The proposed method was successfully applied for the estimation of vilazodone hydrochloride in marketed tablet formulation.Vilazodone Hydrochloride was subjected to forced degradation under Acidic, Alkaline, Oxidation, Dry Heat and Photolytic degradation conditions. Vilazodone hydrochloride showed 3.12% degradation under acidic condition, 4.78% under alkaline condition, 7.8% under oxidation condition, 3.53% under dry heat condition and 4.9% under photolytic condition.Acid degradation impurity was identified and characterised by LC-MS/MS was found to be 1-(4-Penten-1-yl) piperazine having molecular weight 154.253 (m/z 155.08) and Molecular Formula C9H18N2.Conclusion: A simple, precise, rapid and accurate Stability Indicating HPLC method has been developed and validated for the determination of Vilazodone Hydrochloride in presence of its degradation products as per the ICH Guidelines. 


INDIAN DRUGS ◽  
2015 ◽  
Vol 52 (02) ◽  
pp. 20-33
Author(s):  
N. S Kumar ◽  
◽  
R Kumaraswamy ◽  
S. Shantikumar ◽  
D. Paul

The present study describes the separation and simultaneous estimation of eight anti-retroviral drugs, namely, Telaprevir (TPV), Emtricitabine (ECB), Fosamprenavir (FANV), Tenofavir (TNF), Ritonavir (RNV), Raltegravir (RGV) and Oseltamivir (OSMV) and Zidovudine (ZDV) as an active pharmaceutical ingredient, by RP-HPLC method by applying the principles of Quality by Design (QbD). An application of DoE (Design of Experiments) full factorial design was used for initial screening and optimization. The final optimized method consists of separation being carried out on a Fortis C18 column (150 mm × 4.6 mm, 5μ particle size) using acetonitrile and 10 mm ammonium formate buffer (pH 3 adjusted with formic acid) using a gradient program. The quantitative evaluation was performed with a diode array detector at 251 nm and 230 nm with a flow rate of 1 mL min–1. Suitability of this method for the quantitative determination of the drugs was proved by validation in accordance with the International Conference on Harmonization (ICH) guidelines. The method is selective, precise, robust and accurate and can be used for routine analysis of pharmaceutical formulations in quality control and counterfeit screening.


2010 ◽  
Vol 93 (2) ◽  
pp. 523-530 ◽  
Author(s):  
Sérgio Luiz Dalmora ◽  
Maximiliano da Silva Sangoi ◽  
Daniele Rubert Nogueira ◽  
Lucélia Magalhães da Silva

Abstract An RP-HPLC method was validated for the determination of entecavir in tablet dosage form. The HPLC method was carried out on a Gemini C18 column (150 4.6 mm id) maintained at 30C. The mobile phase consisted of acetonitrilewater (95 + 5, v/v)/potassium phosphate buffer (0.01 M, pH 4; 9 + 91, v/v) pumped at a flow rate of 1.0 mL/min. Photodiode array detection was at 253 nm. The chromatographic separation was obtained with a retention time of 4.18 min, and the method was linear in the range of 0.5200 g/mL (r2 0.9998). The specificity and stability-indicating capability of the method was proven through forced degradation studies, which also showed that there was no interference of the excipients and an increase of the cytotoxicity only by the basic condition. The accuracy was 101.19, with bias lower than 1.81. The LOD and LOQ were 0.39 and 0.5 g/mL, respectively. Method validation demonstrated acceptable results for precision and robustness. The proposed method was applied for the analysis of tablet formulations, to improve QC and assure therapeutic efficacy.


2016 ◽  
Vol 9 (1) ◽  
pp. 54
Author(s):  
Megha Sharma ◽  
Neeraj Mahindroo

Objective: The objective of the present study was to develop and validate a novel stability indicating reverse phase-high performance liquid chromatography (RP-HPLC) method for determination of β-acetyldigoxin, an active pharmaceutical ingredient (API).Methods: The chromatographic separation was carried out on Agilent Technologies 1200 series HPLC system equipped with photo diode array detector and C-18 (4.6x250 mm, 5 µ) column. The mobile phase consisted of water: acetonitrile (65:35 v/v), delivered at a flow rate of 1.5 ml/min and eluents were monitored at 225 nm.Results: The retention time of β-acetyldigoxin was 9.2 min. The method was found to be linear (R2= 0.9995) in the range of 31.25-500 µg/ml. The accuracy studies showed the mean percent recovery of 101.02%. LOD and LOQ were observed to be 0.289 µg/ml and 0.965 µg/ml, respectively. The method was found to be robust and system suitability testing was also performed. Forced degradation analysis was carried out under acidic, alkaline, oxidative and photolytic stress conditions. Significant degradation was observed under tested conditions, except for oxidative condition. The method was able to separate all the degradation products within runtime of 20 min and was able to determine β-acetyldigoxin unequivocally in presence of degradation products.Conclusion: The novel, economic, rapid and simple method for analysis of β-acetyldigoxin is reported. The developed method is suitable for routine quality control and its determination as API, and in pharmaceutical formulations and stability study samples.


Sign in / Sign up

Export Citation Format

Share Document